SICK GRTE18-N2417, GRTE18-P2417, GRTE18-N2447, GRTE18-P2447

Contents

SICK GRTE18 Series Photoelectric Switch Sensor User Manual

Models: GRTE18-N2417, GRTE18-P2417, GRTE18-N2447, GRTE18-P2447

Brand: SICK

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the SICK GRTE18 series photoelectric switch sensors. These sensors are designed for reliable object detection in various industrial automation applications. Please read this manual thoroughly before using the product.

2. Safety Instructions

Always observe the following safety precautions to prevent personal injury and damage to the product or connected equipment:

  • Installation and maintenance should only be performed by qualified personnel.
  • Disconnect power before performing any installation, wiring, or maintenance tasks.
  • Ensure proper grounding and wiring according to local electrical codes and the provided wiring diagram.
  • Do not exceed the specified supply voltage or output current ratings.
  • Protect the sensor from mechanical shock, excessive vibration, and extreme temperatures outside its operating range.
  • Do not attempt to modify or repair the sensor. Refer to qualified service personnel.

3. Package Contents

The product package typically includes:

  • 1 x SICK GRTE18 Series Photoelectric Switch Sensor
  • 2 x Mounting Nuts (visible in product image)
  • Product documentation (this manual, if printed)
SICK GRTE18-P2417 Photoelectric Switch Sensor in packaging with specifications and wiring diagram
Figure 1: SICK GRTE18-P2417 Photoelectric Switch Sensor in its original packaging, showing the sensor unit, mounting nuts, and a label with technical specifications and a wiring diagram.

4. Setup and Installation

4.1 Mounting

The GRTE18 sensor features a cylindrical M18 housing for easy mounting. Use the provided mounting nuts to secure the sensor in the desired position. Ensure the sensing face is clear of obstructions and properly aligned with the target object and, if applicable, the reflector.

  • Choose a stable mounting location free from excessive vibration.
  • Ensure the sensor is positioned to achieve the optimal sensing range for your application.
  • Tighten the mounting nuts securely, but do not overtighten.

4.2 Wiring

The sensor uses a standard M12, 4-pin connector. Refer to the wiring diagram below for correct connections. The specific model (NPN or PNP) determines the output type.

Wiring diagram for SICK GRTE18 series sensor with M12 4-pin connector
Figure 2: Detailed wiring diagram for the SICK GRTE18 series photoelectric switch sensor, showing the M12 4-pin connector pin assignments.

Wiring Details:

PinWire ColorFunction
1bn (Brown)Supply Voltage + (Positive)
3bu (Blue)Supply Voltage - (Negative)
4bk (Black)Output (Normally Open - NO)
2wh (White)Output (Normally Closed - NC)

Note: The GRTE18-N models typically feature NPN outputs, while GRTE18-P models feature PNP outputs. Ensure your control system is compatible with the sensor's output type.

5. Operation

The SICK GRTE18 series sensors are diffuse photoelectric switches. They operate by emitting a light beam and detecting the light reflected directly from the target object. When an object enters the sensing range, the reflected light changes, triggering the sensor's output.

  • Power On: Apply the specified DC supply voltage to the sensor.
  • Detection: Position the target object within the sensor's sensing range. The sensor's output will switch state (either NO or NC) upon detection.
  • Indicator: Many SICK sensors include an LED indicator to show detection status. Refer to the product datasheet for specific indicator behavior.

6. Maintenance

The GRTE18 series sensors are designed for low maintenance. Regular inspection and cleaning will ensure optimal performance.

  • Cleaning: Periodically clean the sensor's optical surfaces (lens) with a soft, lint-free cloth. If necessary, use a mild, non-abrasive cleaning solution. Avoid harsh chemicals that could damage the plastic housing.
  • Inspection: Check the sensor and its cabling for any signs of physical damage, wear, or loose connections. Ensure mounting is still secure.
  • Environmental Conditions: Verify that the operating environment remains within the specified temperature and humidity limits.

7. Troubleshooting

If the sensor is not functioning as expected, consider the following common issues:

ProblemPossible CauseSolution
Sensor not detecting objectsIncorrect alignment, dirty lens, object outside sensing range, wiring error, power issue.Check alignment, clean lens, verify object position, inspect wiring, confirm power supply.
Sensor output always ON/OFFContinuous detection/no detection, wiring error, faulty sensor.Adjust sensitivity (if available), check for permanent obstructions/clear path, verify wiring, replace sensor if faulty.
Intermittent detectionUnstable mounting, vibration, fluctuating power, environmental interference.Secure mounting, reduce vibration, stabilize power supply, shield from interference.

8. Technical Specifications

The following specifications apply to the SICK GRTE18 series photoelectric switch sensors:

ParameterValue
Sensor TypePhotoelectric (Diffuse)
Sensing Range5 mm ... 1.0 m (approximate, may vary by model)
Supply VoltageDC (Specific voltage range not provided, typically 10-30V DC for industrial sensors)
Continuous Output Current (Ia)100 mA
Operating Temperature-25°C to 70°C
Connection TypeM12, 4-pin plug
Output TypeNPN (for GRTE18-N models), PNP (for GRTE18-P models) - with NO/NC options
OriginMade in Italy (Manufacturer: SICK AG, D-79183 Waldkirch)
CertificationsCE, cURus
Recycling InformationPE-LD (Low-density polyethylene)

9. User Tips

No specific user tips are available from provided data. General tips for photoelectric sensors include:

  • For reflective or shiny objects, consider adjusting the angle of the sensor slightly to avoid false reflections.
  • Darker objects absorb more light, potentially reducing the effective sensing range.
  • Ensure the sensor's field of view is clear of any background objects that could cause false triggers.

10. Frequently Asked Questions (FAQ)

No specific FAQ content is available from provided data. For common questions, please refer to the manufacturer's official website or contact their support.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official SICK website or contact your local SICK representative. Ensure you have your product model number and any relevant purchase details available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.