1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the STEPPERONLINE A6 Series RS485 AC Servo Motor Kit. The A6-RS is a high-performance servo drive system designed for optimized configurations, higher productivity, and reduced costs. It consists of the A6-RS servo drive and an A6M60 or A6M80 series servo motor, with power ranging from 0.2kW to 1.0kW. The system supports Pulse, RS485, and Analog communication and features a built-in 17-bit multi-turn absolute encoder for excellent servo control performance.

This series of servo products is easy to operate, economical, and efficient, offering an optimal balance between performance and cost.

STEPPERONLINE A6 Series AC Servo Motor Kit
Figure 1.1: STEPPERONLINE A6 Series AC Servo Motor Kit (Servo Driver and Motor)

2. Safety Information

WARNING: Improper use can lead to personal injury or property damage. Always follow safety guidelines.

  • Only personnel qualified for the specific task should operate this product.
  • All operations must adhere to the descriptions, warning notices, and safety instructions provided in this documentation.
  • Do not connect input power cables to output terminals U, V, and W. This can damage the servo drive.
  • Avoid touching power terminals within 10 minutes after power-off, as high voltage may still be present.
  • Do not bundle power cables and signal cables together. Maintain a distance of at least 30 cm to prevent interference.
  • Do not frequently turn the power supply on and off (e.g., once a minute) to avoid drive faults.
  • Ensure all terminal block screws and cables are securely fastened before powering on the servo drive to prevent fire hazards.
  • Use heat-resistant cables (e.g., Teflon) in high ambient temperatures.
  • In low temperatures, take measures to prevent cables from hardening and cracking.
  • Use cables rated for 600 V AC or above and $75^{\circ}C$ or above for the main circuit.
  • The grounding cable should have the same cross-sectional area as the main circuit cable (minimum $1.6 mm^2$, or $2.0 mm^2$ if less than $1.6 mm^2$).
  • Ground the drive reliably to prevent malfunction or damage.
  • Use shielded cables to comply with EMC requirements.

3. Packing List

The following items are typically included in the STEPPERONLINE A6 Series RS485 AC Servo Motor Kit:

  • 1 x 200W Pulse/RS485/Analog AC Servo Motor Driver
  • 1 x 100W AC Servo Motor 3000rpm 0.32Nm 17-Bit (with/without Brake) Encoder IP67 (selected based on order)
  • 1 x 3.0m Motor Cable (with/without brake) (selected based on order)
  • 1 x 3.0m Encoder Cable
Included cables for servo motor kit
Figure 3.1: Motor and Encoder Cables

4. Specifications

4.1. General Product Specifications

Attribute Value
Brand NameSTEPPERONLINE
Model NumberA6 Series 100W RS485 AC Servo Motor Kit
TypeServo Motor
AC Voltage220VAC
EfficiencyIE 1
Protect FeatureWaterproof
IP RatingIP67
CertificationCE
EU LVD VoltageHigh voltage: Above 50Vac or 75Vdc
Wireless functionalityNo
Battery includedNo

4.2. Rated Data for Single-phase 220V Servo Drive

Item SIZE-A (0.2kW) SIZE-A (0.4kW) SIZE-B (0.75kW)
Power0.2kW0.4kW0.75kW
Drive modelA6-200RSA6-400RSA6-750RS
Continuous output current (Arms)1.62.85.5
Maximum output current (Arms)5.810.116.9
Main circuit power supplySingle-phase 200-240 V AC, -10% to +10%, 50/60 Hz
Control circuit power supplyPowered up by the bus, sharing one power supply and rectification part with the main circuit
Braking capabilityExternal braking resistorBuilt-in braking resistor

4.3. Rated Data for Single-phase/Three-phase 220V Servo Drive

Item SIZE-C (1.0kW)
Power1.0kW
Drive modelA6-1000RS
Continuous output current (Arms)7.6
Maximum output current (Arms)23
Main circuit power supplySingle-phase/three-phase 200-240 V AC, -10% to +10%, 50/60 Hz
Control circuit power supplySingle-phase 200-240 V AC, -10% to +10%, 50/60 Hz
Braking capabilityBuilt-in braking resistor

4.4. Technical Specifications

Item Specification
Control modeIGBT PWM control, sine wave current drive mode (220 V, 380 V: Single-phase or three-phase full-bridge rectification)
Encoder feedback17-bit multi-turn absolute encoder (can be used as single-turn absolute encoder without battery)
Operating temperature$0^{\circ}C$ to $+55^{\circ}C$ (derate 10% for every additional $5^{\circ}C$ over $45^{\circ}C$)
Storage temperature$-40^{\circ}C$ to $+70^{\circ}C$
AltitudeUp to 2000 m (derate 1% for every additional 100 m above 1000 m)
IP ratingIP20 (except for the power terminal IPOO)
Speed control range1:6000 (lower limit is threshold for rated torque load)
Frequency characteristic2 kHz
Torque control accuracy±1%
Soft start time setting0s to 3600s (acceleration and deceleration set separately)
Feedforward compensation0% to 100.0% (0.1% FS resolution)
Input pulse form"direction+pulse", "Phase A+B quadrature pulse", "CW/CCW pulse reference form"
Input pulse frequencyDifferential input: Up to 4 Mpps (pulse width ≥ 0.125 μs); Open collector: Up to 200 kpps (pulse width ≥ 2.5 μs)
Multi-position referencePosition 0 to 15 selectable via DI signal combination
Output formPhase A, phase B: differential output; Phase Z: differential output or open collector output
Overtravel (OT) preventionServo drive stops immediately when P-OT or N-OT becomes active
Protection functionsOvercurrent, overvoltage, undervoltage, overload, main circuit detection error, heatsink overheat, overspeed, encoder error, CPU error, parameter error
LED displayMain power supply CHARGE indicator, 5-digit LED display
Vibration suppressionFive notches (including two adaptive notches), 50 Hz to 8000 Hz
Connection protocolUSB
Communication protocolModbus (up to 128 nodes with RS485)
Axis address settingBased on user parameter setting
FunctionStatus display, user parameter setting, monitored value display, alarm tracing, jogging, speed/torque reference signal observation
OtherGain tuning, alarm record, I/O setting, jogging

4.5. Motor Torque-Speed Characteristics

Motor Torque-Speed Characteristics Comparison
Figure 4.1: Comparison of Servo Motor vs. Stepper Motor Characteristics
Motor Torque-Speed Curves for A6M40, A6M60, A6M80 series
Figure 4.2: Motor Torque-Speed Curves for A6M40, A6M60, A6M80 series

5. Installation

The A6-RS series servo drive must be installed on a base using a backplate. Refer to the dimensions diagrams for mounting hole details specific to each model.

5.1. Installation Dimensions

Ensure adequate space for ventilation and cable routing. The following figures provide detailed dimensions for different drive sizes.

Installation dimensions for SIZE A servo drive
Figure 5.1: Installation Dimensions for SIZE A Drive (0.2kW to 0.4kW)
Installation dimensions for SIZE B servo drive
Figure 5.2: Installation Dimensions for SIZE B Drive (0.75kW)
Installation dimensions for SIZE C servo drive
Figure 5.3: Installation Dimensions for SIZE C Drive (1.0kW)

NOTICE: Fixing with upper and lower screws for SIZE-A/B/C requires M4 screws, one each on top and bottom. Torque: 1.3 N·m to 1.6 N·m.

5.2. Motor Dimensions

Refer to the following diagrams for motor dimensions, including models with and without brakes.

Motor dimensions for 100W (40 frame) with and without brake
Figure 5.4: Motor Dimensions for 100W (40 frame) with and without brake

6. Wiring Diagrams and Connections

Carefully follow the wiring instructions to ensure correct and safe operation of the servo motor kit.

6.1. Drive Ports Overview

The servo drive features various ports for control, encoder, communication, and power. Familiarize yourself with their locations and functions.

Ports for SIZE A and SIZE B servo drives
Figure 6.1: Ports for SIZE A and SIZE B Drives
Ports for SIZE C servo drive
Figure 6.2: Ports for SIZE C Drive

6.2. Drive Terminal Pinout

The following tables detail the pin assignments for the drive terminals:

Terminal Pin Description
L1C, L2CControl circuit power inputConnected to the control circuit power supply as per the rated voltage class on the nameplate.
R, S, TMain circuit power inputConnected to the main circuit power supply as per the rated voltage class on the nameplate.
P+, N-Servo bus terminalsUsed when multiple servo drives share one DC bus.
P+, D, CExternal braking resistor connectionIf an external braking resistor is needed, connect it between terminals P+ and C. Remove the jumper between P+ and D before installing.
U, V, WMotor power outputConnected to U, V, and W phases of the servo motor.
PEMotor grounding terminalConnected to the grounding terminal of the motor for grounding purpose.

6.3. CN1 User Control Terminal Pinout

Pin Description
7 (DO1+) / 6 (DO1-)Servo ready
5 (DO2+) / 4 (DO2-)Positioning completed
3 (DO3+) / 2 (DO3-)Brake output
1 (DO4+) / 26 (DO4-)Fault output
28 (DO5+) / 27 (DO5-)Home attaining completed
9 (DI1)Positive limit switch
10 (DI2)Negative limit switch
34 (DI3)Position reference inhibited
8 (DI4)ALM-RST (edge valid function)
33 (DI5)S-ON
32 (DI6)-
12 (DI7)-
30 (DI8)Home switch
17 (24V)Internal 24 V power supply (20-28V, Max 150mA)
14 (COM-) / 11 (COM+)Common terminal of DI terminals
41 (PULSE+) / 43 (PULS-)Low-speed pulse reference mode: Differential drive input / Open collector
37 (SIGN+) / 39 (SIGN-)Input pulse form: Direction+pulse / Phase A+B quadrature pulse / CW/CCW pulse

6.4. CN2 Encoder Terminal Pinout

Pin Description
38 (HPULS+) / 36 (HPULS-)High-speed input pulse reference
42 (HSIGN+) / 40 (HSIGN-)High-speed position reference symbol
35 (PULLH)Input interface of external power supply for reference pulse
21 (PAO+) / 22 (PAO-)A-phase frequency-division output/fully closed-loop input
25 (PBO+) / 23 (PBO-)B-phase frequency-division output/fully closed-loop input
13 (PZO+) / 24 (PZO-)Z-phase frequency-division output/fully closed-loop input
29 (GND)Signal ground
44 (OCZ)Encoder Z-phase open collector output
15 (5V) / 16 (GND)5 V power supply / Power ground
20 (AI1) / 18 (AI2)Analog voltage signal input / Analog current signal input
31 (AO1) / 19 (GND)Analog voltage output / Analog signal ground
1 (+5V) / 2 (0V)5 V power supply / 0 V power supply
5 (PS+) / 6 (PS-)Encoder signal+ / Encoder signal-
Enclosure (PE)Shield

6.5. Electrical Wiring Diagram

The following diagram illustrates the general electrical connections for the servo motor kit. Pay close attention to power supply connections based on your specific model (100W/400W/750W vs. 1000W).

Electrical wiring diagram for servo motor kit
Figure 6.3: General Electrical Wiring Diagram

NOTE: If you have the 1000W version, you need to connect the L1, L2, L3 power cord in parallel according to the diagram shown on the right side of Figure 6.3.

6.6. Motor and Driver Connection Video

Video 6.1: Step-by-step guide on connecting the motor and driver cables.

7. Commissioning Process

Follow these steps for initial commissioning of your servo drive system:

  1. Start: Begin the commissioning process.
  2. Checklist before running: Perform mechanical and wiring inspection and safety checks.
  3. Power on the servo drive: Connect the power supply of the main circuit and control circuit.
  4. Jogging: Perform jogging through the operating panel.
  5. Set parameters: Set common parameters and relevant parameters for each control mode.
  6. Servo running: Run the servo drive at a low speed for the first time. Set relevant parameters to achieve the required effect and commission the servo drive.
  7. Stop the servo drive: Turn off the S-ON signal, stop the servo drive upon a fault, stop if the limit switch is reached, or perform an emergency stop.
  8. Finish: Complete the commissioning process.

7.1. Commissioning Tool (Operating Panel)

The A6-RS series servo drive can be commissioned using its operating panel, which features an LED display area and five buttons.

Servo drive operating panel with LED display and buttons
Figure 7.1: Servo Drive Operating Panel
Button Description
M (MODE)Press: Switch/return to menus. Press and hold: Switch group number in level-2 menus.
▲ (UP)Press: Switch state display in level-1 menus, Increase value.
▼ (DOWN)Press: Switch state display in level-1 menus, Decrease value.
◀ (SHIFT)Press: Move cursor left. Press and hold: Enter JOG mode quickly in level-1 menus, Page up/down.
S (SET)Press: Switch to lower-level menu. Press and hold: Execute commands (e.g., storing parameters).

7.2. Display Menu Navigation

The LED display shows status, parameters, faults, and monitored values. Navigation is hierarchical:

  • Level-1 menu (Status display): Shows model, rotation direction, running mode, servo status. Use ▲/▼ to switch display modes. Press M to enter Level-2.
  • Level-2 menu (Parameter group number): Displays parameter group number in hexadecimal. Press and hold M to switch group number. Press S to enter Level-3. Press M to return to Level-1.
  • Level-3 menu (Offset within parameter group): Shows offset in hexadecimal. Press S to enter Level-4. Press M to return to Level-2.
  • Level-4 menu (Parameter setpoints): Displays parameter setpoints in decimal. Use ▲/▼ to increase/decrease value. Press S to confirm. Press M to return to Level-3.

8. Operating Modes

The A6-RS servo drive supports various control modes, including Speed/Torque control and Position control. Configuration is done via parameters on the operating panel or through Modbus communication.

8.1. Speed/Torque Control Mode

This mode allows for precise control over the motor's speed and torque. Parameters related to speed control range, frequency characteristics, torque accuracy, and soft start time can be configured.

8.2. Position Control Mode

Position control enables accurate positioning of the motor. Key configurable parameters include feedforward compensation, input pulse form, input pulse frequency, multi-position reference, and output form.

8.3. Modbus Protocol

The servo drive parameters can be read and written using the Modbus RTU protocol. Parameters are classified as 16-bit or 32-bit. Refer to the official user manual PDF for detailed Modbus communication examples and frame formats. The PDF can be found at: STEPPERONLINE A6-RS Servo Drive User Guide (PDF)

9. Jogging

Jogging is used for trial runs of the servo motor and drive to verify proper rotation without abnormal vibration or noise.

  1. Power on the servo drive.
  2. Press and hold the SHIFT button (◀) to enter the JOG mode quickly.
  3. Set parameter F30.00 on the panel.
  4. Press S to confirm the setting.
  5. Set the jog speed using ▲/▼.
  6. Confirm the motor speed by pressing S.
  7. The display will show "JOG-S".
  8. Press ▲/▼ to enable forward/reverse motor rotation.
  9. Press M to finish.

NOTICE:

  • During jogging, use F30.03 to set the acceleration/deceleration time constant.
  • Use ▲/▼ to adjust motor speed. If the system exits jog running, the motor speed resets to its initial value.
  • Press and hold ▲/▼ to make the motor rotate. Release to stop.

10. Inertia Auto-tuning

The load inertia ratio is crucial for servo system performance. The A6-RS drive can automatically tune this ratio using the F30.10 function.

  1. Power on the servo drive.
  2. Set parameter F30.10 on the panel.
  3. Press S to confirm the setting.
  4. Set the number of auto-tuning turns using ▲/▼.
  5. Confirm the number of auto-tuning turns by pressing S.
  6. The display will show the inertia value.
  7. Press ▲/▼ to perform auto-tuning on auto/manual gains.
  8. Press M to end.

11. Troubleshooting

This section provides a checklist and a list of common fault and alarm codes to help diagnose and resolve issues.

11.1. Troubleshooting Checklist

  • Are the parameters set properly?
  • Is a fault code displayed?
  • Is the cable of the control signal CN1 wired properly or disconnected?
  • Is the cable of the encoder signal CN2 wired properly or disconnected?
  • Is the power supply voltage correct? Is there power input? Is the connection loose?
  • Is the wiring correct? Is the cable disconnected? Is the short circuit cable disconnected?
  • Is the motor making noise?

11.2. Reset Operation

  • Set F31.00 (Fault reset) to 1 to stop displaying the fault on the panel.
  • To reset resettable faults, switch off the S-ON signal first, then send the fault reset signal (set F31.00 to 1).
  • To reset resettable alarms, eliminate the alarm source, and the servo drive will automatically reset the alarms.

11.3. List of Fault Codes (Class 1)

Fault Code (203F) Fault Name Bus Fault Code (603F) Resettable
0x010Mismatch of software versions0x6100Non-resettable
0x011Mismatch of motor parameters0x7122Non-resettable
0x020Product matching fault. No specified drive0x6100Non-resettable
0x021Product matching fault. No specified motor0x6100Non-resettable
0x022Product matching fault. No specified encoder0x6100Non-resettable
0x025Drive 5 V voltage too low-Non-resettable
0x030System parameter error0x6320Non-resettable
0x031Parameter out-of-range0x6320Non-resettable
0x032Parameter writing error0x6320Non-resettable
0x033Parameter reading error0x6320Non-resettable
0x040FPGA power-on check error0x6100Non-resettable
0x041FPGA power-on not reset0x6100Non-resettable
0x042FPGA transmission interrupted0x6100Non-resettable
0x050Current loop timeout0x7500Non-resettable
0x051Speed loop timeout0x7500Non-resettable
0x052Position loop timeout0x7500Non-resettable
0x060Protection from out of control0x8400Non-resettable
0x100P-hardware overcurrent0x2312Non-resettable
0x101N-hardware overcurrent0x2312Non-resettable
0x102U phase software overcurrent0x2312Non-resettable
0x103V phase software overcurrent0x2312Non-resettable
0x104Output short circuited to ground0x2330Non-resettable
0x105Current sampling failure0x6100Non-resettable
0x106Incorrect current parameter setting0x6320Non-resettable
0x107UV current correction failure0x6100Non-resettable
0x108Excessive current zero drift0x6100Non-resettable
0x109Current exception during enabling0x2312Non-resettable
0x110Excessive motor speed upon servo drive power-on-Non-resettable
0x111Drive over-temperature0x2312Non-resettable
0x120PWM buffer detection failure-Non-resettable
0x201Encoder internal fault0x7305Non-resettable
0x202Encoder reading/writing error0x7305Non-resettable
0x203Encoder data frame loss0x7305Non-resettable
0x204Excessive encoder incremental position0x7305Non-resettable
0x205Abnormal encoder data0x7305Non-resettable
0x206Mismatch of encoder type0x7305Non-resettable
0x207Encoder model not supported0x7305Non-resettable
0x208Encoder battery failure0x7305Non-resettable
0x209Encoder multi-turn error0x7305Non-resettable
0x210Mismatch between encoder pulses per revolution and drive pulses per revolution0x7305Non-resettable
0x220Second encoder disconnection0x7305Non-resettable
0x221Fully closed-loop BISS encoder timed out0x7305Non-resettable
0x222Communication data error of fully closed-loop BISS encoder0x7305Non-resettable
0x223Check error of fully closed-loop BISS encoder0x7305Non-resettable
0x224Internal error of fully closed-loop BISS encoder0x7305Non-resettable
0x225Power-on reading position error in fully closed-loop BISS absolute value mode0x7305Non-resettable
0x400Drive overload0x3230Resettable
0x410Motor overload0x3230Resettable
0x411Motor over-temperature due to locked-rotor0x7121Resettable
0x412Motor over-temperature (PTC)0x4210Resettable
0x413Motor winding temperature is too high0x4210Resettable
0x420IGBT temperature too high0x4210Resettable
0x421Discharge tube temperature too high0x4210Resettable
0x422Heatsink temperature too high0x4210Resettable
0x430Overvoltage0x3210Resettable
0x431Undervoltage0x3220Resettable
0x450S-ON enabling failure0xFF00Resettable
0x460Motor overspeed0x8400Resettable
0x470Excessive position deviation0x8611Resettable
0x471Position deviation overflow0x8611Resettable
0x472Excessive fully closed-loop mixed deviation0x8611Resettable
0x480STO status exception0x0480Resettable
0x481STO buffer 5 V power fault0x0481Resettable
0x482Optocoupler fault in STO pulse detection0x0482Resettable
0x483STO buffer detection failure0x0483Resettable
0x490Output phase loss of power cable-Resettable
0x501D/Q current overflow0x6100Resettable
0x510Offline inertia auto-tuning failure0x6310Resettable
0x511Offline inertia parameter error0x6310Resettable
0x520Angle auto-tuning failure0x7122Resettable
0x530Motor parameter auto-tuning timeout0x7122Resettable
0x531Resistance parameter auto-tuning failure0x7122Resettable
0x532Inductance parameter auto-tuning failure0x7122Resettable
0x533Back EMF parameter auto-tuning failure0x7122Resettable
0x540Current loop auto-tuning failure0x7122Resettable
0x550Excessive vibration0x7122Resettable
0x570Friction auto-tuning failed0x7122Resettable
0x800Control power undervoltage0x3120Resettable
0x810Input phase loss 10x3130Resettable
0x811Input phase loss 20x3130Resettable
0x820DI function allocation fault0x6320Resettable
0x821DO function allocation fault0x6320Resettable
0x822VDI function allocation fault0xFF00Resettable
0x823VDO function allocation fault0xFF00Resettable
0x824Position capture DI function allocation error0x824Resettable
0x830AI1 sampling overvoltage0x6100Resettable
0x831AI2 sampling overvoltage0x6100Resettable
0x832AI1 chip missing or clock failure-Resettable
0x833AI2 chip missing or clock failure-Resettable
0x834Current-type AI disconnected-Resettable
0x835Current-type sampling overcurrent fault-Resettable
0x840Electronic gear ratio setting error0x6320Resettable
0x841Software limit setting error0x6320Resettable
0x842Encoder resolution setting error0x7122Resettable
0x843Home position setting error0xFF00Resettable
0x851Frequency-division pulse output error0x7500Resettable
0x870Position reference increment error (pulse)0xFF00Resettable
0x873Overflow of 32-bit sign bit of the target position during limiting0xFF00Resettable
0x874Target position exceeding maximum value of mechanical single-turn position in rotating mode0xFF00Resettable
0x875Fully closed-loop parameter setting error0x0875Resettable
0xA01Multi-turn overflow fault0x7305Resettable

11.4. List of Alarm Codes (Class 3)

Alarm Code (203F) Alarm Name Bus Fault Code (603F) Resettable
0x0F00Emergency stop alarm0xF00Resettable
0xF10Re-power-on required for parameter settings to take effect0x6320Resettable
0xF11Frequent parameter storage alarm0x5530Resettable
0xF12Torque reached parameter error0x6320Resettable
0xF20Forward overtravel alarm0x5443Resettable
0xF21Reverse overtravel alarm0x5444Resettable
0xF30The AI1 zero offset is too large-Resettable
0xF31The AI2 zero offset is too large-Resettable
0xF40Homing timeout0x6320Resettable
0xF41Homing DI conflict0x6320Resettable
0xF42Homing mode conflict0x6320Resettable
0xF50Braking resistor overload0x3210Resettable
0xF51Too small resistance of external regenerative resistor0x6320Resettable
0xF60Abnormal setting of frequency division pulse output-Resettable
0xF61Output phase loss0x3230Resettable
0xF70Warning that the planning start segment number is greater than the end segment number-Resettable
0xF73Initial segment of position comparison in cyclic absolute mode out of the comparison segment range-Resettable
0xF80Vibration occurred during auto-tuning0x7122Resettable
0xF90Encoder battery voltage low0x7305Resettable
0xFA0Drive high temperature warning0x7305Resettable
0xFB0Brake PMOS short circuit0x0FB0Resettable
0xFB1Brake NMOS short circuit0x0FB1Resettable
0xFB2Brake 24 V disconnection or open circuit0x0FB2Resettable
0xFFFFServo not ready-Resettable

12. User Tips

  • Always double-check all wiring connections before powering on the system to prevent damage.
  • When performing auto-tuning, ensure the motor is free to move without obstruction for accurate results.
  • For optimal performance, regularly check for and clear any fault or alarm codes.
  • If experiencing unexpected behavior, review the troubleshooting checklist and fault code tables before contacting support.
  • Keep the operating panel clean and free from dust to ensure clear display and responsive button operation.

13. Maintenance

Regular maintenance helps ensure the longevity and reliable operation of your STEPPERONLINE A6 Series Servo Motor Kit.

  • Cleaning: Keep the servo drive and motor free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using solvents or abrasive cleaners.
  • Connection Checks: Periodically inspect all cable connections (power, motor, encoder, communication) to ensure they are secure and free from damage. Tighten any loose screws.
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges. Avoid exposure to excessive moisture, corrosive gases, or strong vibrations.
  • Cooling: Verify that the cooling fins on the servo drive are not obstructed to allow for proper heat dissipation.
  • Software Updates: Check the manufacturer's website for any available firmware updates for the servo drive to ensure optimal performance and access to new features.

14. Warranty and Support

For detailed warranty information and technical support, please refer to the official STEPPERONLINE website or contact their customer service. Ensure you have your product model number and any relevant fault codes ready when seeking support.

The official user manual PDF contains additional detailed information and can be downloaded from: STEPPERONLINE A6-RS Servo Drive User Guide (PDF)

© 2024 STEPPERONLINE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.