1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the STEPPERONLINE A6 Series RS485 AC Servo Motor Kit. The A6-RS is a high-performance servo drive system designed for optimized configurations, higher productivity, and reduced costs. It consists of the A6-RS servo drive and an A6M60 or A6M80 series servo motor, with power ranging from 0.2kW to 1.0kW. The system supports Pulse, RS485, and Analog communication and features a built-in 17-bit multi-turn absolute encoder for excellent servo control performance.
This series of servo products is easy to operate, economical, and efficient, offering an optimal balance between performance and cost.
2. Safety Information
WARNING: Improper use can lead to personal injury or property damage. Always follow safety guidelines.
- Only personnel qualified for the specific task should operate this product.
- All operations must adhere to the descriptions, warning notices, and safety instructions provided in this documentation.
- Do not connect input power cables to output terminals U, V, and W. This can damage the servo drive.
- Avoid touching power terminals within 10 minutes after power-off, as high voltage may still be present.
- Do not bundle power cables and signal cables together. Maintain a distance of at least 30 cm to prevent interference.
- Do not frequently turn the power supply on and off (e.g., once a minute) to avoid drive faults.
- Ensure all terminal block screws and cables are securely fastened before powering on the servo drive to prevent fire hazards.
- Use heat-resistant cables (e.g., Teflon) in high ambient temperatures.
- In low temperatures, take measures to prevent cables from hardening and cracking.
- Use cables rated for 600 V AC or above and $75^{\circ}C$ or above for the main circuit.
- The grounding cable should have the same cross-sectional area as the main circuit cable (minimum $1.6 mm^2$, or $2.0 mm^2$ if less than $1.6 mm^2$).
- Ground the drive reliably to prevent malfunction or damage.
- Use shielded cables to comply with EMC requirements.
3. Packing List
The following items are typically included in the STEPPERONLINE A6 Series RS485 AC Servo Motor Kit:
- 1 x 200W Pulse/RS485/Analog AC Servo Motor Driver
- 1 x 100W AC Servo Motor 3000rpm 0.32Nm 17-Bit (with/without Brake) Encoder IP67 (selected based on order)
- 1 x 3.0m Motor Cable (with/without brake) (selected based on order)
- 1 x 3.0m Encoder Cable
4. Specifications
4.1. General Product Specifications
| Attribute | Value |
|---|---|
| Brand Name | STEPPERONLINE |
| Model Number | A6 Series 100W RS485 AC Servo Motor Kit |
| Type | Servo Motor |
| AC Voltage | 220VAC |
| Efficiency | IE 1 |
| Protect Feature | Waterproof |
| IP Rating | IP67 |
| Certification | CE |
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc |
| Wireless functionality | No |
| Battery included | No |
4.2. Rated Data for Single-phase 220V Servo Drive
| Item | SIZE-A (0.2kW) | SIZE-A (0.4kW) | SIZE-B (0.75kW) |
|---|---|---|---|
| Power | 0.2kW | 0.4kW | 0.75kW |
| Drive model | A6-200RS | A6-400RS | A6-750RS |
| Continuous output current (Arms) | 1.6 | 2.8 | 5.5 |
| Maximum output current (Arms) | 5.8 | 10.1 | 16.9 |
| Main circuit power supply | Single-phase 200-240 V AC, -10% to +10%, 50/60 Hz | ||
| Control circuit power supply | Powered up by the bus, sharing one power supply and rectification part with the main circuit | ||
| Braking capability | External braking resistor | Built-in braking resistor | |
4.3. Rated Data for Single-phase/Three-phase 220V Servo Drive
| Item | SIZE-C (1.0kW) |
|---|---|
| Power | 1.0kW |
| Drive model | A6-1000RS |
| Continuous output current (Arms) | 7.6 |
| Maximum output current (Arms) | 23 |
| Main circuit power supply | Single-phase/three-phase 200-240 V AC, -10% to +10%, 50/60 Hz |
| Control circuit power supply | Single-phase 200-240 V AC, -10% to +10%, 50/60 Hz |
| Braking capability | Built-in braking resistor |
4.4. Technical Specifications
| Item | Specification |
|---|---|
| Control mode | IGBT PWM control, sine wave current drive mode (220 V, 380 V: Single-phase or three-phase full-bridge rectification) |
| Encoder feedback | 17-bit multi-turn absolute encoder (can be used as single-turn absolute encoder without battery) |
| Operating temperature | $0^{\circ}C$ to $+55^{\circ}C$ (derate 10% for every additional $5^{\circ}C$ over $45^{\circ}C$) |
| Storage temperature | $-40^{\circ}C$ to $+70^{\circ}C$ |
| Altitude | Up to 2000 m (derate 1% for every additional 100 m above 1000 m) |
| IP rating | IP20 (except for the power terminal IPOO) |
| Speed control range | 1:6000 (lower limit is threshold for rated torque load) |
| Frequency characteristic | 2 kHz |
| Torque control accuracy | ±1% |
| Soft start time setting | 0s to 3600s (acceleration and deceleration set separately) |
| Feedforward compensation | 0% to 100.0% (0.1% FS resolution) |
| Input pulse form | "direction+pulse", "Phase A+B quadrature pulse", "CW/CCW pulse reference form" |
| Input pulse frequency | Differential input: Up to 4 Mpps (pulse width ≥ 0.125 μs); Open collector: Up to 200 kpps (pulse width ≥ 2.5 μs) |
| Multi-position reference | Position 0 to 15 selectable via DI signal combination |
| Output form | Phase A, phase B: differential output; Phase Z: differential output or open collector output |
| Overtravel (OT) prevention | Servo drive stops immediately when P-OT or N-OT becomes active |
| Protection functions | Overcurrent, overvoltage, undervoltage, overload, main circuit detection error, heatsink overheat, overspeed, encoder error, CPU error, parameter error |
| LED display | Main power supply CHARGE indicator, 5-digit LED display |
| Vibration suppression | Five notches (including two adaptive notches), 50 Hz to 8000 Hz |
| Connection protocol | USB |
| Communication protocol | Modbus (up to 128 nodes with RS485) |
| Axis address setting | Based on user parameter setting |
| Function | Status display, user parameter setting, monitored value display, alarm tracing, jogging, speed/torque reference signal observation |
| Other | Gain tuning, alarm record, I/O setting, jogging |
4.5. Motor Torque-Speed Characteristics
5. Installation
The A6-RS series servo drive must be installed on a base using a backplate. Refer to the dimensions diagrams for mounting hole details specific to each model.
5.1. Installation Dimensions
Ensure adequate space for ventilation and cable routing. The following figures provide detailed dimensions for different drive sizes.
NOTICE: Fixing with upper and lower screws for SIZE-A/B/C requires M4 screws, one each on top and bottom. Torque: 1.3 N·m to 1.6 N·m.
5.2. Motor Dimensions
Refer to the following diagrams for motor dimensions, including models with and without brakes.
6. Wiring Diagrams and Connections
Carefully follow the wiring instructions to ensure correct and safe operation of the servo motor kit.
6.1. Drive Ports Overview
The servo drive features various ports for control, encoder, communication, and power. Familiarize yourself with their locations and functions.
6.2. Drive Terminal Pinout
The following tables detail the pin assignments for the drive terminals:
| Terminal | Pin | Description |
|---|---|---|
| L1C, L2C | Control circuit power input | Connected to the control circuit power supply as per the rated voltage class on the nameplate. |
| R, S, T | Main circuit power input | Connected to the main circuit power supply as per the rated voltage class on the nameplate. |
| P+, N- | Servo bus terminals | Used when multiple servo drives share one DC bus. |
| P+, D, C | External braking resistor connection | If an external braking resistor is needed, connect it between terminals P+ and C. Remove the jumper between P+ and D before installing. |
| U, V, W | Motor power output | Connected to U, V, and W phases of the servo motor. |
| PE | Motor grounding terminal | Connected to the grounding terminal of the motor for grounding purpose. |
6.3. CN1 User Control Terminal Pinout
| Pin | Description |
|---|---|
| 7 (DO1+) / 6 (DO1-) | Servo ready |
| 5 (DO2+) / 4 (DO2-) | Positioning completed |
| 3 (DO3+) / 2 (DO3-) | Brake output |
| 1 (DO4+) / 26 (DO4-) | Fault output |
| 28 (DO5+) / 27 (DO5-) | Home attaining completed |
| 9 (DI1) | Positive limit switch |
| 10 (DI2) | Negative limit switch |
| 34 (DI3) | Position reference inhibited |
| 8 (DI4) | ALM-RST (edge valid function) |
| 33 (DI5) | S-ON |
| 32 (DI6) | - |
| 12 (DI7) | - |
| 30 (DI8) | Home switch |
| 17 (24V) | Internal 24 V power supply (20-28V, Max 150mA) |
| 14 (COM-) / 11 (COM+) | Common terminal of DI terminals |
| 41 (PULSE+) / 43 (PULS-) | Low-speed pulse reference mode: Differential drive input / Open collector |
| 37 (SIGN+) / 39 (SIGN-) | Input pulse form: Direction+pulse / Phase A+B quadrature pulse / CW/CCW pulse |
6.4. CN2 Encoder Terminal Pinout
| Pin | Description |
|---|---|
| 38 (HPULS+) / 36 (HPULS-) | High-speed input pulse reference |
| 42 (HSIGN+) / 40 (HSIGN-) | High-speed position reference symbol |
| 35 (PULLH) | Input interface of external power supply for reference pulse |
| 21 (PAO+) / 22 (PAO-) | A-phase frequency-division output/fully closed-loop input |
| 25 (PBO+) / 23 (PBO-) | B-phase frequency-division output/fully closed-loop input |
| 13 (PZO+) / 24 (PZO-) | Z-phase frequency-division output/fully closed-loop input |
| 29 (GND) | Signal ground |
| 44 (OCZ) | Encoder Z-phase open collector output |
| 15 (5V) / 16 (GND) | 5 V power supply / Power ground |
| 20 (AI1) / 18 (AI2) | Analog voltage signal input / Analog current signal input |
| 31 (AO1) / 19 (GND) | Analog voltage output / Analog signal ground |
| 1 (+5V) / 2 (0V) | 5 V power supply / 0 V power supply |
| 5 (PS+) / 6 (PS-) | Encoder signal+ / Encoder signal- |
| Enclosure (PE) | Shield |
6.5. Electrical Wiring Diagram
The following diagram illustrates the general electrical connections for the servo motor kit. Pay close attention to power supply connections based on your specific model (100W/400W/750W vs. 1000W).
NOTE: If you have the 1000W version, you need to connect the L1, L2, L3 power cord in parallel according to the diagram shown on the right side of Figure 6.3.
6.6. Motor and Driver Connection Video
7. Commissioning Process
Follow these steps for initial commissioning of your servo drive system:
- Start: Begin the commissioning process.
- Checklist before running: Perform mechanical and wiring inspection and safety checks.
- Power on the servo drive: Connect the power supply of the main circuit and control circuit.
- Jogging: Perform jogging through the operating panel.
- Set parameters: Set common parameters and relevant parameters for each control mode.
- Servo running: Run the servo drive at a low speed for the first time. Set relevant parameters to achieve the required effect and commission the servo drive.
- Stop the servo drive: Turn off the S-ON signal, stop the servo drive upon a fault, stop if the limit switch is reached, or perform an emergency stop.
- Finish: Complete the commissioning process.
7.1. Commissioning Tool (Operating Panel)
The A6-RS series servo drive can be commissioned using its operating panel, which features an LED display area and five buttons.
| Button | Description |
|---|---|
| M (MODE) | Press: Switch/return to menus. Press and hold: Switch group number in level-2 menus. |
| ▲ (UP) | Press: Switch state display in level-1 menus, Increase value. |
| ▼ (DOWN) | Press: Switch state display in level-1 menus, Decrease value. |
| ◀ (SHIFT) | Press: Move cursor left. Press and hold: Enter JOG mode quickly in level-1 menus, Page up/down. |
| S (SET) | Press: Switch to lower-level menu. Press and hold: Execute commands (e.g., storing parameters). |
7.2. Display Menu Navigation
The LED display shows status, parameters, faults, and monitored values. Navigation is hierarchical:
- Level-1 menu (Status display): Shows model, rotation direction, running mode, servo status. Use ▲/▼ to switch display modes. Press M to enter Level-2.
- Level-2 menu (Parameter group number): Displays parameter group number in hexadecimal. Press and hold M to switch group number. Press S to enter Level-3. Press M to return to Level-1.
- Level-3 menu (Offset within parameter group): Shows offset in hexadecimal. Press S to enter Level-4. Press M to return to Level-2.
- Level-4 menu (Parameter setpoints): Displays parameter setpoints in decimal. Use ▲/▼ to increase/decrease value. Press S to confirm. Press M to return to Level-3.
8. Operating Modes
The A6-RS servo drive supports various control modes, including Speed/Torque control and Position control. Configuration is done via parameters on the operating panel or through Modbus communication.
8.1. Speed/Torque Control Mode
This mode allows for precise control over the motor's speed and torque. Parameters related to speed control range, frequency characteristics, torque accuracy, and soft start time can be configured.
8.2. Position Control Mode
Position control enables accurate positioning of the motor. Key configurable parameters include feedforward compensation, input pulse form, input pulse frequency, multi-position reference, and output form.
8.3. Modbus Protocol
The servo drive parameters can be read and written using the Modbus RTU protocol. Parameters are classified as 16-bit or 32-bit. Refer to the official user manual PDF for detailed Modbus communication examples and frame formats. The PDF can be found at: STEPPERONLINE A6-RS Servo Drive User Guide (PDF)
9. Jogging
Jogging is used for trial runs of the servo motor and drive to verify proper rotation without abnormal vibration or noise.
- Power on the servo drive.
- Press and hold the SHIFT button (◀) to enter the JOG mode quickly.
- Set parameter F30.00 on the panel.
- Press S to confirm the setting.
- Set the jog speed using ▲/▼.
- Confirm the motor speed by pressing S.
- The display will show "JOG-S".
- Press ▲/▼ to enable forward/reverse motor rotation.
- Press M to finish.
NOTICE:
- During jogging, use F30.03 to set the acceleration/deceleration time constant.
- Use ▲/▼ to adjust motor speed. If the system exits jog running, the motor speed resets to its initial value.
- Press and hold ▲/▼ to make the motor rotate. Release to stop.
10. Inertia Auto-tuning
The load inertia ratio is crucial for servo system performance. The A6-RS drive can automatically tune this ratio using the F30.10 function.
- Power on the servo drive.
- Set parameter F30.10 on the panel.
- Press S to confirm the setting.
- Set the number of auto-tuning turns using ▲/▼.
- Confirm the number of auto-tuning turns by pressing S.
- The display will show the inertia value.
- Press ▲/▼ to perform auto-tuning on auto/manual gains.
- Press M to end.
11. Troubleshooting
This section provides a checklist and a list of common fault and alarm codes to help diagnose and resolve issues.
11.1. Troubleshooting Checklist
- Are the parameters set properly?
- Is a fault code displayed?
- Is the cable of the control signal CN1 wired properly or disconnected?
- Is the cable of the encoder signal CN2 wired properly or disconnected?
- Is the power supply voltage correct? Is there power input? Is the connection loose?
- Is the wiring correct? Is the cable disconnected? Is the short circuit cable disconnected?
- Is the motor making noise?
11.2. Reset Operation
- Set F31.00 (Fault reset) to 1 to stop displaying the fault on the panel.
- To reset resettable faults, switch off the S-ON signal first, then send the fault reset signal (set F31.00 to 1).
- To reset resettable alarms, eliminate the alarm source, and the servo drive will automatically reset the alarms.
11.3. List of Fault Codes (Class 1)
| Fault Code (203F) | Fault Name | Bus Fault Code (603F) | Resettable |
|---|---|---|---|
| 0x010 | Mismatch of software versions | 0x6100 | Non-resettable |
| 0x011 | Mismatch of motor parameters | 0x7122 | Non-resettable |
| 0x020 | Product matching fault. No specified drive | 0x6100 | Non-resettable |
| 0x021 | Product matching fault. No specified motor | 0x6100 | Non-resettable |
| 0x022 | Product matching fault. No specified encoder | 0x6100 | Non-resettable |
| 0x025 | Drive 5 V voltage too low | - | Non-resettable |
| 0x030 | System parameter error | 0x6320 | Non-resettable |
| 0x031 | Parameter out-of-range | 0x6320 | Non-resettable |
| 0x032 | Parameter writing error | 0x6320 | Non-resettable |
| 0x033 | Parameter reading error | 0x6320 | Non-resettable |
| 0x040 | FPGA power-on check error | 0x6100 | Non-resettable |
| 0x041 | FPGA power-on not reset | 0x6100 | Non-resettable |
| 0x042 | FPGA transmission interrupted | 0x6100 | Non-resettable |
| 0x050 | Current loop timeout | 0x7500 | Non-resettable |
| 0x051 | Speed loop timeout | 0x7500 | Non-resettable |
| 0x052 | Position loop timeout | 0x7500 | Non-resettable |
| 0x060 | Protection from out of control | 0x8400 | Non-resettable |
| 0x100 | P-hardware overcurrent | 0x2312 | Non-resettable |
| 0x101 | N-hardware overcurrent | 0x2312 | Non-resettable |
| 0x102 | U phase software overcurrent | 0x2312 | Non-resettable |
| 0x103 | V phase software overcurrent | 0x2312 | Non-resettable |
| 0x104 | Output short circuited to ground | 0x2330 | Non-resettable |
| 0x105 | Current sampling failure | 0x6100 | Non-resettable |
| 0x106 | Incorrect current parameter setting | 0x6320 | Non-resettable |
| 0x107 | UV current correction failure | 0x6100 | Non-resettable |
| 0x108 | Excessive current zero drift | 0x6100 | Non-resettable |
| 0x109 | Current exception during enabling | 0x2312 | Non-resettable |
| 0x110 | Excessive motor speed upon servo drive power-on | - | Non-resettable |
| 0x111 | Drive over-temperature | 0x2312 | Non-resettable |
| 0x120 | PWM buffer detection failure | - | Non-resettable |
| 0x201 | Encoder internal fault | 0x7305 | Non-resettable |
| 0x202 | Encoder reading/writing error | 0x7305 | Non-resettable |
| 0x203 | Encoder data frame loss | 0x7305 | Non-resettable |
| 0x204 | Excessive encoder incremental position | 0x7305 | Non-resettable |
| 0x205 | Abnormal encoder data | 0x7305 | Non-resettable |
| 0x206 | Mismatch of encoder type | 0x7305 | Non-resettable |
| 0x207 | Encoder model not supported | 0x7305 | Non-resettable |
| 0x208 | Encoder battery failure | 0x7305 | Non-resettable |
| 0x209 | Encoder multi-turn error | 0x7305 | Non-resettable |
| 0x210 | Mismatch between encoder pulses per revolution and drive pulses per revolution | 0x7305 | Non-resettable |
| 0x220 | Second encoder disconnection | 0x7305 | Non-resettable |
| 0x221 | Fully closed-loop BISS encoder timed out | 0x7305 | Non-resettable |
| 0x222 | Communication data error of fully closed-loop BISS encoder | 0x7305 | Non-resettable |
| 0x223 | Check error of fully closed-loop BISS encoder | 0x7305 | Non-resettable |
| 0x224 | Internal error of fully closed-loop BISS encoder | 0x7305 | Non-resettable |
| 0x225 | Power-on reading position error in fully closed-loop BISS absolute value mode | 0x7305 | Non-resettable |
| 0x400 | Drive overload | 0x3230 | Resettable |
| 0x410 | Motor overload | 0x3230 | Resettable |
| 0x411 | Motor over-temperature due to locked-rotor | 0x7121 | Resettable |
| 0x412 | Motor over-temperature (PTC) | 0x4210 | Resettable |
| 0x413 | Motor winding temperature is too high | 0x4210 | Resettable |
| 0x420 | IGBT temperature too high | 0x4210 | Resettable |
| 0x421 | Discharge tube temperature too high | 0x4210 | Resettable |
| 0x422 | Heatsink temperature too high | 0x4210 | Resettable |
| 0x430 | Overvoltage | 0x3210 | Resettable |
| 0x431 | Undervoltage | 0x3220 | Resettable |
| 0x450 | S-ON enabling failure | 0xFF00 | Resettable |
| 0x460 | Motor overspeed | 0x8400 | Resettable |
| 0x470 | Excessive position deviation | 0x8611 | Resettable |
| 0x471 | Position deviation overflow | 0x8611 | Resettable |
| 0x472 | Excessive fully closed-loop mixed deviation | 0x8611 | Resettable |
| 0x480 | STO status exception | 0x0480 | Resettable |
| 0x481 | STO buffer 5 V power fault | 0x0481 | Resettable |
| 0x482 | Optocoupler fault in STO pulse detection | 0x0482 | Resettable |
| 0x483 | STO buffer detection failure | 0x0483 | Resettable |
| 0x490 | Output phase loss of power cable | - | Resettable |
| 0x501 | D/Q current overflow | 0x6100 | Resettable |
| 0x510 | Offline inertia auto-tuning failure | 0x6310 | Resettable |
| 0x511 | Offline inertia parameter error | 0x6310 | Resettable |
| 0x520 | Angle auto-tuning failure | 0x7122 | Resettable |
| 0x530 | Motor parameter auto-tuning timeout | 0x7122 | Resettable |
| 0x531 | Resistance parameter auto-tuning failure | 0x7122 | Resettable |
| 0x532 | Inductance parameter auto-tuning failure | 0x7122 | Resettable |
| 0x533 | Back EMF parameter auto-tuning failure | 0x7122 | Resettable |
| 0x540 | Current loop auto-tuning failure | 0x7122 | Resettable |
| 0x550 | Excessive vibration | 0x7122 | Resettable |
| 0x570 | Friction auto-tuning failed | 0x7122 | Resettable |
| 0x800 | Control power undervoltage | 0x3120 | Resettable |
| 0x810 | Input phase loss 1 | 0x3130 | Resettable |
| 0x811 | Input phase loss 2 | 0x3130 | Resettable |
| 0x820 | DI function allocation fault | 0x6320 | Resettable |
| 0x821 | DO function allocation fault | 0x6320 | Resettable |
| 0x822 | VDI function allocation fault | 0xFF00 | Resettable |
| 0x823 | VDO function allocation fault | 0xFF00 | Resettable |
| 0x824 | Position capture DI function allocation error | 0x824 | Resettable |
| 0x830 | AI1 sampling overvoltage | 0x6100 | Resettable |
| 0x831 | AI2 sampling overvoltage | 0x6100 | Resettable |
| 0x832 | AI1 chip missing or clock failure | - | Resettable |
| 0x833 | AI2 chip missing or clock failure | - | Resettable |
| 0x834 | Current-type AI disconnected | - | Resettable |
| 0x835 | Current-type sampling overcurrent fault | - | Resettable |
| 0x840 | Electronic gear ratio setting error | 0x6320 | Resettable |
| 0x841 | Software limit setting error | 0x6320 | Resettable |
| 0x842 | Encoder resolution setting error | 0x7122 | Resettable |
| 0x843 | Home position setting error | 0xFF00 | Resettable |
| 0x851 | Frequency-division pulse output error | 0x7500 | Resettable |
| 0x870 | Position reference increment error (pulse) | 0xFF00 | Resettable |
| 0x873 | Overflow of 32-bit sign bit of the target position during limiting | 0xFF00 | Resettable |
| 0x874 | Target position exceeding maximum value of mechanical single-turn position in rotating mode | 0xFF00 | Resettable |
| 0x875 | Fully closed-loop parameter setting error | 0x0875 | Resettable |
| 0xA01 | Multi-turn overflow fault | 0x7305 | Resettable |
11.4. List of Alarm Codes (Class 3)
| Alarm Code (203F) | Alarm Name | Bus Fault Code (603F) | Resettable |
|---|---|---|---|
| 0x0F00 | Emergency stop alarm | 0xF00 | Resettable |
| 0xF10 | Re-power-on required for parameter settings to take effect | 0x6320 | Resettable |
| 0xF11 | Frequent parameter storage alarm | 0x5530 | Resettable |
| 0xF12 | Torque reached parameter error | 0x6320 | Resettable |
| 0xF20 | Forward overtravel alarm | 0x5443 | Resettable |
| 0xF21 | Reverse overtravel alarm | 0x5444 | Resettable |
| 0xF30 | The AI1 zero offset is too large | - | Resettable |
| 0xF31 | The AI2 zero offset is too large | - | Resettable |
| 0xF40 | Homing timeout | 0x6320 | Resettable |
| 0xF41 | Homing DI conflict | 0x6320 | Resettable |
| 0xF42 | Homing mode conflict | 0x6320 | Resettable |
| 0xF50 | Braking resistor overload | 0x3210 | Resettable |
| 0xF51 | Too small resistance of external regenerative resistor | 0x6320 | Resettable |
| 0xF60 | Abnormal setting of frequency division pulse output | - | Resettable |
| 0xF61 | Output phase loss | 0x3230 | Resettable |
| 0xF70 | Warning that the planning start segment number is greater than the end segment number | - | Resettable |
| 0xF73 | Initial segment of position comparison in cyclic absolute mode out of the comparison segment range | - | Resettable |
| 0xF80 | Vibration occurred during auto-tuning | 0x7122 | Resettable |
| 0xF90 | Encoder battery voltage low | 0x7305 | Resettable |
| 0xFA0 | Drive high temperature warning | 0x7305 | Resettable |
| 0xFB0 | Brake PMOS short circuit | 0x0FB0 | Resettable |
| 0xFB1 | Brake NMOS short circuit | 0x0FB1 | Resettable |
| 0xFB2 | Brake 24 V disconnection or open circuit | 0x0FB2 | Resettable |
| 0xFFFF | Servo not ready | - | Resettable |
12. User Tips
- Always double-check all wiring connections before powering on the system to prevent damage.
- When performing auto-tuning, ensure the motor is free to move without obstruction for accurate results.
- For optimal performance, regularly check for and clear any fault or alarm codes.
- If experiencing unexpected behavior, review the troubleshooting checklist and fault code tables before contacting support.
- Keep the operating panel clean and free from dust to ensure clear display and responsive button operation.
13. Maintenance
Regular maintenance helps ensure the longevity and reliable operation of your STEPPERONLINE A6 Series Servo Motor Kit.
- Cleaning: Keep the servo drive and motor free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using solvents or abrasive cleaners.
- Connection Checks: Periodically inspect all cable connections (power, motor, encoder, communication) to ensure they are secure and free from damage. Tighten any loose screws.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges. Avoid exposure to excessive moisture, corrosive gases, or strong vibrations.
- Cooling: Verify that the cooling fins on the servo drive are not obstructed to allow for proper heat dissipation.
- Software Updates: Check the manufacturer's website for any available firmware updates for the servo drive to ensure optimal performance and access to new features.
14. Warranty and Support
For detailed warranty information and technical support, please refer to the official STEPPERONLINE website or contact their customer service. Ensure you have your product model number and any relevant fault codes ready when seeking support.
The official user manual PDF contains additional detailed information and can be downloaded from: STEPPERONLINE A6-RS Servo Drive User Guide (PDF)