Hantek DPO7504U

Contents

Hantek DPO7504U Digital Phosphor Oscilloscope User Manual

Model: DPO7504U

Brand: Hantek

1. Introduction

The Hantek DPO7504U is a high-performance 4-channel Digital Phosphor Oscilloscope integrated with a 1-channel Waveform Generator. It features a 500MHz bandwidth, 2GSa/s real-time sampling rate, and an impressive 2Gpts memory depth, allowing for detailed waveform analysis. With a waveform capture rate of 500,000wfms/s and a 10.1-inch multi-touch capacitive screen, it offers a comprehensive and intuitive user experience for various electrical measurement tasks. This device integrates the functions of seven independent instruments, simplifying your measurement system and speeding up your workflow.

Product Overview Video

Description: This video provides an unboxing and initial overview of the Hantek DPO7000 series oscilloscope, highlighting its key features and included accessories.

2. Setup

2.1 Unpacking and Inspection

Carefully unpack the oscilloscope and all accessories. Verify the contents against the packing list provided in the box. Ensure the calibration certificate and warranty card are present. The machine is qualified as proven by the calibration certificate.

2.2 Included Accessories

  • 1 x Type-C Data Cable (for communication between the oscilloscope and a PC)
  • 1 x Power Cord
  • 4 x Passive Probes (for connecting to the circuit under test and the oscilloscope's input terminals)
  • Calibration Certificate
  • Packing List
  • Warranty Card
Accessories table showing instrument, data cable, passive probes, power line, and packing list.

Image: Accessories table showing the main instrument, data cable, passive probes, power line, and packing list.

2.3 Power Connection

Connect the provided power cord to the oscilloscope's power input and a suitable power outlet. The oscilloscope supports a power supply of 110-250 volts standard voltage. Ensure you use the correct plug type for your region.

Diagram showing different plug types: EU, US, UK, AU.

Image: Illustration of various power plug types (EU, US, UK, AU) and their regional usage.

2.4 Probe Connection

Connect the passive probes to the desired input channels (CH1, CH2, CH3, CH4) on the front panel of the oscilloscope. The probes are essential for connecting the circuit under test to the oscilloscope's input terminals.

3. Operating Instructions

The DPO7504U features a 10.1-inch multi-touch capacitive screen for intuitive operation.

3.1 25MHz Function/Arbitrary Waveform Generator

The built-in waveform generator supports a variety of commonly used waveforms and allows for customized arbitrary waveform, arbitrary wave burst output, and modulated waveform output.

Screenshot of the oscilloscope display showing a generated waveform and settings for the 25MHz function/arbitrary waveform generator.

Image: Oscilloscope display demonstrating the 25MHz function/arbitrary waveform generator.

3.2 2G Memory Depth

The ultra-long memory depth of 2Gpts allows for a full understanding of waveform overall and details, ensuring no accidental events or waveform changes are missed.

Screenshot of the oscilloscope display showing a waveform with 2G sampling rate and 2G storage depth.

Image: Oscilloscope display illustrating 2G sampling rate and 2G storage depth.

3.3 Area Trigger Function

By drawing a region on the screen, you can set a region trigger. This simplifies advanced trigger operations and quickly isolates the waveform of interest.

Screenshot of the oscilloscope display showing the area trigger function in use.

Image: Oscilloscope display demonstrating the area trigger function.

3.4 Test Parameter Function

The oscilloscope includes a 5-digit digital voltmeter and a 6-digit hardware frequency meter. Real-time statistics of minimum, maximum, average, and standard deviation enable more efficient test execution.

Screenshot of the oscilloscope display showing test parameter functions and measurements.

Image: Oscilloscope display showing test parameter functions.

3.5 Waveform Recording and Playback

The waveform recording function allows you to record waveform changes in real-time without interruption, marking the time on the signal. This facilitates convenient playback and fault identification.

Screenshot of the oscilloscope display showing waveform recording and playback interface.

Image: Oscilloscope display showing waveform recording and playback.

3.6 Quick Operation Function

A shortcut operation panel with 14 common functions can be accessed with one button, making operations faster and measurements more efficient.

Screenshot of the oscilloscope display showing the quick operation function panel.

Image: Oscilloscope display showing the quick operation function panel.

3.7 Serial Bus Triggering and Decoding

The oscilloscope provides bus triggering and decoding functions, supporting multiple protocols such as UART, I2C, SPI, LIN, and CAN. It can quickly and intuitively decode and display bus protocol information.

Screenshot of the oscilloscope display showing serial bus triggering and decoding.

Image: Oscilloscope display showing serial bus triggering and decoding.

3.8 Waveform Digital Fluorescent Display

The multi-level waveform grayscale display effect helps users quickly find potential anomalies in the signal.

Screenshot of the oscilloscope display showing waveform digital fluorescent display.

Image: Oscilloscope display showing waveform digital fluorescent display.

4. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the oscilloscope. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device.
  • Storage: Store the oscilloscope in a clean, dry environment, away from direct sunlight, extreme temperatures, and high humidity.
  • Probe Care: Handle probes carefully. Avoid bending or stressing the cables. Store them properly to prevent damage.
  • Ventilation: Ensure the ventilation openings on the device are not obstructed to prevent overheating.

5. Troubleshooting

  • No Power: Check the power cord connection and ensure the power outlet is functional. Verify the power switch is in the 'ON' position.
  • No Signal Display: Ensure probes are correctly connected to both the oscilloscope and the circuit under test. Check probe settings (e.g., 1X/10X attenuation) and channel settings on the oscilloscope. Adjust vertical and horizontal scales.
  • Distorted Waveform: Check probe compensation. Ensure the input impedance setting (1MΩ or 50Ω) matches the probe and circuit requirements.
  • Unresponsive Touchscreen: Try restarting the device. If the issue persists, refer to the official support resources.
  • Communication Issues with PC: Ensure the Type-C data cable is securely connected. Verify that the correct drivers are installed on your PC.

6. Specifications

Table of detailed specifications for the Hantek DPO7504U oscilloscope.

Image: Detailed specifications table for the DPO7504U.

FeatureSpecification
ModelDPO7504U
Channel4 Channel Oscilloscope + 1 Channel Waveform Generator
Bandwidth500MHz
Real-time Sampling Rate2GSa/s (single channel), 2GSa/s (half channel), 1GSa/s (all channel)
Memory Depth2Gpts (single channel), 1Gpts (dual channel), 500Mpts (three-four channels), 250Mpts (full channel)
Waveform Capture Rate500,000 wfms/s (25ns dot display single channel automatic memory depth)
Vertical Resolution8 bit
Vertical Sensitivity1 MΩ: 500µV/div ~ 10 V/div; 50 Ω: 500µV/div ~ 1 V/div
Time Base Range500ps/div~1ks/div
Time Base Accuracy±1 ppm ± 1 ppm/year
Bandwidth Limitation20 MHz, 100MHz, 200MHz, 350MHz; Independent optional for each channel
Trigger TypeEdge, Pulse, Video, Slope, Overtime, Window, Logic, Overamp, Runt, Pattern, Delay, Setup/Hold, Nth Edge, UART, LIN, CAN, SPI, I2C
Bus and DecodingUART, I2C, SPI, LIN, CAN
Mathematical OperationA+B, A-B, A*B, A/B, FFT, A&&B, A||B, !A, Intg, Diff, Sqrt, Lg, Ln, Exp, Abs, LowPass, HighPass, BandPass, BandStop, AX+B, Expression
Automatic Measurement51 kinds of parameter measurement, supporting statistics and analysis
Analysis FunctionFrequency meter, DVM, Power Analyzer, Histogram, Search, Navigate, Record, Bode Set
Hardware Recording and PlaybackMore than 2 million frames (single channel)
Input CouplingDC, AC or GND
Input Impedance and Capacitance1 MΩ ± 1%, 50 Ω ± 1%; 19 pF ± 3 pF
Arbitrary Waveform GeneratorSampling rate 200 MSa/s, vertical resolution 12 bit, maximum output frequency 25 MHz, Sine, Square, Pulse, Ramp, Noise, DC, Sinc, Exp.rise, Exp.fall, Lorentz, Gauss, ECG, Haversine and other 13 standard waveforms
InterfaceUSB HOST, USB DEVICE, LAN; option: HDMI, serial port
Screen10.1 inch multi-touch capacitive screen, 256 level waveform grayscale display, with color afterglow

7. User Tips

  • Feature Limitations: Please note that the DPO7504U model does not include advanced functions such as logic analyzer, trigger decoding, power analysis, Bode plot, or protocol generator. The operating language is exclusively English.
  • Manuals and Data Sheets: For detailed user manuals and data sheets, you can visit the official Hantek website. This resource can provide further guidance for operation and usage.

8. Warranty and Support

Your Hantek DPO7504U oscilloscope comes with a warranty card. Please retain this document for any warranty claims. For technical support, service, or to download the latest user manuals and software, please visit the official Hantek website:

Hantek Official Product Page

It is recommended to consult the official website for the most up-to-date information and resources.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.