1. Introduction
The eletechsup 25IOA08, 25IOB16, and 25IOC32 series are advanced PNP Output RS485 IO modules designed for industrial control and automation. These modules offer a robust solution for digital input and output control, featuring photoelectric isolation for enhanced reliability. They are compatible with RS485 Modbus RTU commands, enabling seamless integration into various systems such as PLCs, smart home setups, and security monitoring.
2. Key Features
- Working Voltage: DC 7-25V (compatible with 9V, 12V, 24V systems).
- Working Current: 10-48mA.
- Input Ports: 8, 16, or 32 photoelectrically isolated input channels, supporting NPN/PNP configurations (optional).
- Output Ports: 8, 16, or 32 DMOS PNP outputs, providing high-level output with a drive current of 300mA per channel.
- Output Modes: Supports multiple output modes including Open, Close, Toggle (Self-locking), Latch (Inter-locking), Momentary (Non-locking), and Delay.
- Remote Control: Input ports can remotely control the output ports of another module via the RS485 bus.
- MODBUS Command Support: Command 1 supports 03, 06, 16 function codes. Command 2 supports 01, 02, 03, 05, 06, 15, 16 function codes.
- Maximum Delay: Up to 255 seconds under MODBUS Command 1.
- Parallel Devices: Up to 64 devices can be supported in parallel in MODBUS command mode.
- Baud Rate: Default 9600BPS, configurable to 1200, 2400, 4800, 19200, 38400, 57600, or 115200BPS.
- Protection Feature: Epoxy encapsulation.
- Theory: Solid State Relay.
3. Technical Specifications
| Parameter | Description |
|---|---|
| Product Series | 25IOA08 (8-Channel), 25IOB16 (16-Channel), 25IOC32 (32-Channel) |
| Power Source | DC |
| Voltage Range | DC 7-25V |
| Contact Load | Low Power |
| Max Output Current per Channel | 300mA |
| Dimensions (Only Board) | 8CH: 61x72x18MM 16CH: 106x72x18MM 32CH: 196x72x18MM |
| Dimensions (With DIN Box) | 8CH: 64x80x30MM 16CH: 109x80x30MM 32CH: 199x80x30MM |
| Weight (Only Board) | 8CH: 46g 16CH: 80g 32CH: 152g |
| Weight (With DIN Box) | 8CH: 85g 16CH: 145g 32CH: 247g |
4. Package Contents
The package typically includes:
- 1 x eletechsup 25IOA08/25IOB16/25IOC32 Series RS485 IO Module (based on selected channel count and NPN/PNP type)
- Optional: DIN Rail Mount Box (if selected with box option)
5. Setup and Wiring
Before connecting, ensure the power supply is disconnected. Refer to the specific wiring diagrams below for your application. The modules are available in 8, 16, or 32 channels, and can be NPN or PNP input types, with PNP outputs.
5.1 Module Overview
The image below shows the different channel versions of the eletechsup RS485 IO modules, highlighting the PNP DO (Digital Output) capability. The M0 port is used for command selection, and a RESET port is available to restore factory settings by short-circuiting it for 5 seconds.


5.2 Wiring Diagram for Driving PLC Amplifier Board
This diagram illustrates how to connect the module to a PLC amplifier board. Pay close attention to the IN (Input) and GND connections, as well as the RS485 A+ and B- terminals.

5.3 Application 2: Reading Switch Input via RS485 Bus
This application shows wiring for both NPN and PNP switch inputs to the module, which then communicates the switch status via the RS485 bus. Ensure the power supply (DC 7-25V) is correctly connected.

5.4 Application 3: Input and Output Amplifier (Direct Control)
This diagram details how to configure the module for direct control where an input directly controls an output. It covers both NPN and PNP input types, resulting in a PNP output. Note that for this function, you may need to configure the 0x00FA(250) register via the RS485 bus.

5.5 Application 4: 8-32 Channel Remote Control Input/Output via RS485 Bus
This advanced application demonstrates how to use two modules for remote control of inputs and outputs over the RS485 bus. It includes specific instructions for enabling remote IO sender and receiver registers. The RS485 address must be the same for both modules.

6. Operating Instructions
The eletechsup RS485 IO module operates using MODBUS RTU commands over an RS485 serial connection. A computer or PLC can send commands to control the outputs or read the status of the inputs.
6.1 Modbus Communication
- Connect the module to your computer or PLC via an RS485 to USB converter or directly to an RS485 port.
- Use Modbus Poll software (or similar Modbus master software) to communicate with the module.
- Configure the serial port settings: Baud rate (default 9600BPS, configurable), 8 data bits, None parity, 1 stop bit.
- The module supports MODBUS function codes 01, 02, 03, 05, 06, 15, 16 for reading inputs and controlling outputs.
6.2 Output Control Modes
The module offers various output control modes:
- Open/Close: Directly turn outputs ON or OFF.
- Toggle (Self-locking): Each command toggles the output state (ON to OFF, OFF to ON).
- Latch (Inter-locking): Activating one output deactivates others in a group.
- Momentary (Non-locking): Output is active only while the command is held, then returns to OFF.
- Delay: Output remains active for a specified duration (up to 255 seconds with Modbus Command 1).
6.3 Modbus Poll Software Demonstration
This video demonstrates the interaction with the module using Modbus Poll software, showing how to configure the connection and send commands to control the outputs.
Demonstration of Modbus Poll Software Interaction with the IO Module
7. Applications
The eletechsup RS485 IO module is suitable for a wide range of applications, including but not limited to:
- PLC PNP Output control
- RS485 Remote Control systems
- Smart Home and Home Automation systems
- PTZ IP Camera control
- Security Monitoring systems
- Identification systems
- LED Lamp Drivers
- Automatic curtain control
8. Maintenance
- Keep the module in a dry, dust-free environment.
- Ensure proper ventilation to prevent overheating.
- Regularly check wiring connections for looseness or damage.
- Avoid exposing the module to extreme temperatures or corrosive substances.
- Clean the module gently with a soft, dry cloth if necessary. Do not use liquid cleaners.
9. Troubleshooting
- No Power: Check the DC 7-25V power supply connections and ensure the voltage is within the specified range.
- Communication Issues: Verify RS485 wiring (A+ to A+, B- to B-), baud rate settings, and parity settings in your Modbus master software. Ensure the correct COM port is selected.
- Output Not Responding: Check the output wiring and the load connected to the output. Ensure the output current does not exceed 300mA per channel. Verify the Modbus command sent is correct for the desired output mode.
- Input Not Reading: Check the input wiring for NPN/PNP sensors. Ensure the input signal voltage is compatible with the module's input specifications.
- Module Unresponsive: Try performing a factory reset by short-circuiting the RESET port for 5 seconds.
10. User Tips
No specific user tips were available from reviews or Q&A for this product. However, general advice for industrial IO modules includes:
- Always double-check wiring before applying power to prevent damage.
- When using multiple modules on the same RS485 bus, ensure each module has a unique Modbus address.
- For long RS485 communication lines, consider using termination resistors at both ends of the bus to prevent signal reflections.
- Familiarize yourself with the Modbus RTU protocol and the specific function codes used by this module for effective programming.
11. Warranty and Support
For warranty information, technical support, or further inquiries, please contact the seller directly through the platform where the product was purchased. Ensure you have your order details and product model number ready for faster assistance.