ITECH IT-M3100D Series

Contents

ITECH IT-M3100D Series Dual-Channel DC Power Supply

User Manual for Models IT-M3131D, IT-M3141D, IT-M3132D, IT-M3142D

1. Introduction

The ITECH IT-M3100D series is an ultra-compact, wide-range dual-channel DC power supply designed for various testing applications. This series offers high performance in a small footprint, making it suitable for laboratory, industrial, and educational environments. It features independent dual channels, flexible output configurations, and advanced control capabilities.

Front view of ITECH IT-M3100D series dual-channel DC power supply
Front view of the ITECH IT-M3100D series dual-channel DC power supply, highlighting its ultra-compact design and wide range capabilities. The display shows voltage and current readings, and various control buttons are visible.

2. Safety Information

Please read all safety instructions carefully before operating the device. Failure to comply with these instructions may result in electric shock, fire, or damage to the product.

  • Always connect the power supply to a grounded AC outlet.
  • Do not operate the device in wet or damp conditions.
  • Ensure proper ventilation to prevent overheating.
  • Do not open the casing; there are no user-serviceable parts inside. Refer servicing to qualified personnel.
  • Verify that the input voltage matches the power supply's rating before connecting.
  • Avoid touching output terminals when the device is powered on.

3. Product Components and Overview

3.1 Front Panel

The front panel features the main display, control buttons, and a rotary encoder for setting parameters. The display provides real-time voltage and current readings for both channels.

Close-up of front panel controls of ITECH IT-M3100D series DC power supply
Close-up of the front panel of the ITECH IT-M3100D series DC power supply, detailing the display, function buttons (CH1, CH2, Config, Function, Set, Trigger, Lock, Enter), and the rotary encoder for adjustments.

3.2 Rear Panel

The rear panel includes the AC power input, Ethernet ports for network connectivity, and the output terminals for Channel 1 (CH1) and Channel 2 (CH2). It also features interface expansion slots for optional accessories.

Rear view of ITECH IT-M3100D series DC power supply with connection ports
Rear view of the ITECH IT-M3100D series DC power supply, showing the AC power input, Ethernet IN/OUT ports, and the CH1 and CH2 output terminals.

4. Initial Setup

  1. Unpacking: Carefully remove the power supply from its packaging and inspect for any signs of damage.
  2. Placement: Place the unit on a stable, level surface with adequate ventilation around all sides. Do not block the ventilation openings.
  3. Power Connection: Connect the supplied AC power cord to the power input on the rear panel and then to a grounded AC power outlet.
  4. Load Connection: Connect your load to the CH1 and/or CH2 output terminals on the rear panel using appropriate wiring. Ensure correct polarity.
  5. Optional Interface Connection: If using optional accessories, insert them into the interface expansion slots on the rear panel and connect any necessary cables (e.g., USB, LAN, GPIB, RS-232/CAN, Analog/RS485).
Diagram of IT-M3100D features including optional accessories
Diagram illustrating key features of the IT-M3100D series, including CC & CV priority function waveforms, a screenshot of the web server interface, and a table and diagram of optional accessory interface expansion slots. The table lists models IT-E1205 (GPIB), IT-E1206 (USB/LAN), IT-E1207 (RS-232/CAN), IT-E1208 (Analog/RS485), IT-E1208D (Double channel analog/RS485), and IT-E1209 (USB interface.

4.1 Optional Accessories Interfaces

The rear panel supports various interface expansion modules:

Model Interface
IT-E1205 GPIB interface
IT-E1206 USB/LAN interface
IT-E1207 RS-232/CAN interface
IT-E1208 Analog interface/RS485 interface
IT-E1208D Double channel analog/RS485 interface
IT-E1209 USB interface

5. Operation

5.1 Basic Operation

  • Power On/Off: Press the power button on the front panel to turn the unit on or off.
  • Setting Voltage/Current: Use the CH1/CH2 buttons to select the desired channel. Use the rotary encoder and 'Set' button to adjust voltage and current limits.
  • Output On/Off: Use the 'On/Off' button to enable or disable the output to the load.

5.2 Advanced Features

5.2.1 CC & CV Priority Function

The CC (Constant Current) and CV (Constant Voltage) priority function helps to solve severe problems in long-term testing. You can select the CV priority mode to obtain a faster voltage rising speed, or choose CC priority mode to output current without overshoot. This function is beneficial for applications such as laser testing, IC testing, charge and discharge testing, power transient simulation, and characterization of automotive electronics.

5.2.2 Web Server Access

The IT-M3100D series has a built-in Web server. You can monitor and control it through your web browser. After the IT-M3100D is connected via LAN interface, enter the IP address of the power supply in the browser to access the web interface. This allows remote control and configuration of LAN parameters.

The IT-M3100D supports synchronization functionality for both single and multi-channel power supply systems. There are three synchronization modes: On/Off, Track, and Duplicate. These modes allow parameters to be automatically replicated or proportionally synced to other power supplies in the link. The ON/OFF function utilizes the ON/OFF delay function in the menu for synchronous or sequential power-on operations.

Diagrams for Synchronism (Link) and Multi-Protection Functions
Diagrams demonstrating the Synchronism (Link) function with "synchronous power on" and "sequentially power on" modes for multiple units. Also shows icons representing the Multi-Protection Functions: OVP (Over Voltage Protection), OCP (Over Current Protection), OPP (Over Power Protection), U-Max/U-Min (Under/Over Voltage Limit), Sense (Remote Sense), and Foldback.

5.2.4 Multi-Protection Functions

The IT-M3100D dual-channel DC power supply includes various protection functions to safeguard the device and the connected load:

  • OVP (Over Voltage Protection): Protects the load from excessive voltage.
  • OCP (Over Current Protection): Protects the load from excessive current.
  • OPP (Over Power Protection): Protects the power supply from excessive power output.
  • U-Max/U-Min (Under/Over Voltage Limit): Sets upper and lower voltage limits.
  • Sense (Remote Sense): Compensates for voltage drop in the load wires.
  • Foldback: The output turns off when the power CV/CC is switched, protecting sensitive loads from overshoot.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the unit. Do not use abrasive cleaners or solvents.
  • Ventilation: Regularly check that the ventilation openings are clear of dust and debris to ensure proper airflow.
  • Storage: When not in use for extended periods, store the power supply in a cool, dry environment, away from direct sunlight and extreme temperatures.
  • Calibration: Periodic calibration by qualified service personnel is recommended to maintain accuracy.

7. Troubleshooting

If you encounter issues with your IT-M3100D series power supply, refer to the following common problems and solutions:

Problem Possible Cause Solution
No power/Unit does not turn on Power cord not connected, power outlet faulty, internal fuse blown. Check power cord connection. Test outlet with another device. If fuse is suspected, contact support.
No output voltage/current Output disabled, OVP/OCP/OPP triggered, load disconnected or faulty. Ensure output is enabled. Check protection settings and reset if necessary. Verify load connection and integrity.
Unstable output Poor load connection, remote sense not properly configured, external interference. Check load wiring for loose connections. Ensure remote sense is correctly wired if used. Isolate from strong electromagnetic fields.
Overheating Blocked ventilation, operating in high ambient temperature, excessive load. Ensure ventilation openings are clear. Operate within specified ambient temperature range. Reduce load if continuously overheating.

8. Specifications

The following table details the technical specifications for the IT-M3141D and IT-M3142D models. Specifications for other models in the IT-M3100D series may vary.

Detailed technical specifications table for ITECH IT-M3141D and IT-M3142D models
Detailed technical specifications table for ITECH IT-M3141D and IT-M3142D models, covering electrical characteristics, accuracy, ripple, temperature coefficients, and physical parameters.
Parameter IT-M3141D (CH1 & CH2) IT-M3142D (CH1 & CH2)
Rated Output Value
Voltage 0~30V 0~60V
Current 0~15A 0~10A
Power 0~400W 0~400W
Power Regulation
Voltage (±% of Output+Offset) ≤0.02%+0.005%FS ≤0.02%+0.005%FS
Current (±% of Output+Offset) ≤0.01%+0.01%FS ≤0.01%+0.01%FS
Load Regulation
Voltage (±% of Output+Offset) ≤0.005%+0.005%FS ≤0.005%+0.005%FS
Current ≤1mV ≤1mV
Setup Resolution
Voltage 1mV 1mV
Current 1mA 1mA
Readback Resolution
Voltage 1mV 1mV
Current 1mA 1mA
Setting Accuracy
Voltage ≤0.02%+0.02%FS ≤0.02%+0.02%FS
Current ≤0.1%+0.1%FS ≤0.1%+0.1%FS
Resistance ≤1%+1%FS ≤1%+1%FS
Readback Accuracy
Voltage ≤0.03%+0.02%FS ≤0.03%+0.02%FS
Current ≤0.1%+0.1%FS ≤0.1%+0.1%FS
Ripple (20Hz-20MHz)
Peak value ≤60mVpp ≤60mVpp
Ripple (20Hz-20MHz) Current(RMS)
Current ≤15mA ≤15mA
Temperature Coefficients
Setting Temperature ≤0.005%+0.5mV ≤0.005%+0.5mV
Readback Temperature ≤0.005%+0.5mV ≤0.005%+0.5mV
Falling Time (full load)
Voltage ≤30ms ≤30ms
Falling Time (no load)
Voltage ≤30ms ≤30ms
Dynamic Mode
Voltage 100VAC~240VAC (rated power) 100VAC~240VAC (rated power)
AC Input
Frequency 50/60Hz 50/60Hz
Setup Stability-30min ≤0.01%+0.01%FS ≤0.01%+0.01%FS
Efficiency 85% 85%
Remote Sense Compensation Voltage ≤2V ≤2V
Constant Response Time 1ms 1ms
Power Factor 0.98 0.98
Maximum Input Current 10A 10A
Maximum Input Apparent Power 10VA 10VA
Net Weight (5±0.5) kg (5±0.5) kg

*Net Weight is information subject to change without notice.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your authorized ITECH distributor or visit the official ITECH website. Ensure you have your product model and serial number available when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.