The AIFEN F5PRO is an industrial-grade 1000W hot air rework station designed for precision electronics soldering and repair, including BGA, SMD, and PCB work. It features an intelligent control system with a 2.8-inch IPS color high-definition full view LCD screen, offering accurate temperature control, a quick-change heating core, and flexible switching between curve and general heating modes. Direct control buttons on the handle enhance operational convenience.

AIFEN F5PRO Hot Air Rework Station with 2.8-inch IPS Color LCD, showing accurate temperature, quick change heating core, curve/general switching, and handle button direct control.
Figure 1: AIFEN F5PRO Hot Air Rework Station highlighting key features.

2. Safety Information

Please read and understand all safety instructions before using the AIFEN F5PRO Hot Air Rework Station. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always operate the device in a well-ventilated area.
  • The hot air gun produces extremely high temperatures. Avoid direct contact with the nozzle or heated components.
  • Wear appropriate personal protective equipment, including heat-resistant gloves and eye protection.
  • Ensure the device is properly grounded to prevent electric shock.
  • Do not use the device near flammable materials or gases.
  • Unplug the device from the power outlet before performing any maintenance or changing accessories.
  • Keep the device out of reach of children.
  • The device is ESD safe, but proper ESD precautions should still be observed when working with sensitive electronic components.

3. Package Contents

Verify that all items listed below are included in your package:

  • AIFEN F5PRO Main Unit
  • Hot Air Gun Handle
  • Handle Bracket (Stand)
  • Various Nozzles (typically 4-6 different sizes/shapes)
  • Power Cord
  • Instruction Manual (this document)
AIFEN F5PRO Hot Air Rework Station with various nozzles and handle stand, highlighting its maturity, simplicity, intelligence, convenience, and low cost.
Figure 2: Complete AIFEN F5PRO package contents.

4. Specifications

FeatureSpecification
Model NumberAIFEN -F5PRO
Power1000W
Display2.8-inch IPS Color High-definition Full View LCD Screen
Heating ModesStandard, Curve
Airflow TypeStraight wind + Spiral wind (Patented SUGOON design)
Max Air Volume160
Temperature Unit°C / °F (selectable)
Memory Channels3 (CH1, CH2, CH3)
Weight2.27 kg
Dimensions (L x W x H)21.7cm x 15.5cm x 13.1cm
Package Dimensions (L x W x H)42cm x 35cm x 20cm
CertificationsCE, RoHS, WEEE
OriginMainland China
AIFEN F5PRO Hot Air Rework Station with dimensions (21.7cm L, 15.5cm W, 13.1cm H) and weight (2.27kg) indicated.
Figure 3: AIFEN F5PRO dimensions and weight.

5. Setup

  1. Unpack: Carefully remove all components from the packaging.
  2. Connect Hot Air Gun Handle: Insert the hot air gun handle connector into the corresponding port on the main unit. Twist to secure it firmly. No screws are needed for this connection.
  3. Position Handle Bracket: Place the handle bracket (stand) in a stable location next to the main unit.
  4. Place Handle: Rest the hot air gun handle securely in its bracket when not in use.
  5. Power Connection: Connect the power cord to the main unit and then to a suitable grounded power outlet.
Close-up of the AIFEN F5PRO hot air gun handle showing easy disassembly and assembly with a plug-in design.
Figure 4: Hot air gun handle plug-in and twist assembly.

6. Operating Instructions

6.1 Power On/Off

To power on the device, flip the main power switch located on the front panel. The LCD screen will illuminate, displaying the AIFEN F5PRO logo and then the main operating interface. To power off, flip the switch back to the off position.

6.2 Display Overview

The 2.8-inch IPS LCD screen provides real-time information:

  • Set Temp: Desired temperature setting.
  • Actual Temp: Current temperature of the hot air gun.
  • Air Volume: Current airflow setting.
  • Sleeping: Indicates when the hot air gun is in sleep mode (e.g., placed in the stand).
  • CH1, CH2, CH3: Indicators for the three memory channels.
  • Roc: Indicates Curve Mode.
Diagram of the AIFEN F5PRO control panel and hot air gun handle, labeling power switch, memory storage, curve mode button, menu navigation, temperature/air volume adjustment buttons, and handle bracket.
Figure 5: Control panel and handle functions.

6.3 Temperature and Air Volume Adjustment

You can adjust temperature and air volume using the dedicated buttons on the main unit or directly from the hot air gun handle.

  • Main Unit: Use the '+' and '-' buttons next to 'TEMP' for temperature adjustment and next to 'AIR' for air volume adjustment.
  • Handle: The hot air gun handle features direct control buttons. Use the up/down arrows to adjust temperature or air volume. A short press on the switch key on the handle allows you to toggle between adjusting air volume and temperature.

6.4 Memory Storage (CH1, CH2, CH3)

The AIFEN F5PRO has three memory channels (CH1, CH2, CH3) to store and quickly recall your preferred temperature and air volume settings. To save a setting, adjust the temperature and air volume to your desired levels, then long-press one of the CH buttons until it flashes or indicates saving. To recall a setting, simply short-press the desired CH button.

6.5 System Settings

Access the system settings menu using the navigation buttons on the main unit. Here you can customize various parameters:

  • Heating Mode: Switch between 'Standard' and 'Curve' heating modes.
  • Language Settings: Choose between Chinese and English.
  • Sound Settings: Turn sound notifications ON or OFF.
  • Temperature Unit: Select between Celsius (°C) and Fahrenheit (°F).
  • Temperature Calibration: Adjust temperature calibration if needed.
  • Sleep Air Volume: Set the air volume when the device enters sleep mode.
  • Sleep Switch: Enable or disable the sleep function.
  • Background Color: Choose from 16 different background colors for the display.
  • Brightness: Adjust the display brightness.
  • Handle Function: Configure the handle buttons to adjust either memory settings or air volume/temperature directly.
  • Key Doubling Speed: Set the speed multiplier (e.g., 5x, 10x) for button presses to quickly change values.
  • Return to Home Page: Option to return to the main display.
AIFEN F5PRO LCD screen displaying system settings menu with options for heating mode, language, sound, temperature unit, calibration, and sleep air volume.
Figure 6: System Settings menu on the AIFEN F5PRO.

6.6 Cold Wind Function

Long-press the dedicated switch key on the hot air gun handle to activate the cold wind function. The cold air volume can be set in the system settings.

6.7 Curve Mode Switching

The AIFEN F5PRO allows for advanced curve heating profiles. To switch to curve mode, press the 'Roc' (Curve Mode Conversion) button on the main unit. Once in curve mode, you can set specific temperature and time data points. After setting the data, simply press the button on the handle to initiate the programmed heating curve.

6.8 Patented Air Outlet Design

The F5PRO features a patented SUGOON air outlet design that integrates both straight and spiral wind for efficient and safe heating. This design ensures that the air outlet itself does not generate heat, and the heated area does not blow air directly, enhancing safety and control.

6.9 Video Demonstration

Video 1: Comprehensive demonstration of AIFEN F5PRO features, including fast temperature adjustment, memory presets, system settings, direct handle controls, patented air outlet design, easy heating core replacement, and curve mode operation.

7. Maintenance

7.1 Cleaning

  • Ensure the device is unplugged and completely cooled down before cleaning.
  • Wipe the exterior of the main unit and handle with a soft, dry cloth.
  • Do not use abrasive cleaners or solvents.
  • Keep the air inlet and outlet free from dust and debris to ensure proper airflow.

7.2 Heating Core Replacement

The AIFEN F5PRO features a quick-change heating core for easy replacement:

  1. Ensure the hot air gun is unplugged and completely cooled.
  2. Unscrew the front part of the hot air gun handle to expose the heating core.
  3. Gently pull out the old heating core.
  4. Insert the new heating core, ensuring it aligns correctly.
  5. Screw the front part of the handle back on and twist to tighten. No special tools or screws are required.
Internal diagram of the AIFEN F5PRO chassis, showing the electronic components and power supply.
Figure 7: Internal chassis view (for reference, not user-serviceable).

8. Troubleshooting

  • Device does not power on: Check if the power cord is securely connected to both the unit and the power outlet. Ensure the power switch is in the 'ON' position. Verify the power outlet is functional.
  • No heat or insufficient airflow: Check if the hot air gun handle is properly connected to the main unit. Ensure temperature and air volume settings are correctly configured. The heating core might need replacement if it's old or damaged.
  • Inaccurate temperature reading: Perform a temperature calibration through the system settings menu.
  • Display issues: Check brightness settings in the system menu. If the issue persists, power cycle the device.
  • Handle buttons unresponsive: Check the 'Handle Function' setting in the system menu to ensure it's configured as desired (Memory or Temp/Air adjustment).

9. User Tips

  • Utilize Memory Channels: Save your most frequently used temperature and air volume settings to CH1, CH2, and CH3 for quick access and consistent results across different tasks.
  • Experiment with Heating Modes: The 'Standard' mode is great for general use, while the 'Curve' mode offers precise control for delicate or complex rework processes. Don't hesitate to explore both to find what works best for your application.
  • Direct Handle Control: Take advantage of the direct adjustment buttons on the hot air gun handle for on-the-fly changes to temperature and air volume without needing to reach for the main unit.
  • Cold Wind for Cooling: Use the cold wind function to quickly cool down components after soldering, preventing damage and speeding up your workflow.
  • Regular Cleaning: Keep the air inlets and outlets clean to maintain optimal performance and extend the lifespan of your rework station.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's contact information or the manufacturer's official website. Keep your proof of purchase for any warranty claims.


Related Documents - F5 Pro

Preview AIFEN-868D SMD Rework Station User Manual
This user manual provides comprehensive information for the AIFEN-868D SMD Rework Station. It covers essential safety precautions, detailed product features and specifications, operational guidance for temperature and air volume settings, component installation and replacement procedures, and troubleshooting tips. Designed for efficient and safe electronics rework.
Preview AIFEN-F4 1000W Intelligent Hot Air Rework Station User Manual
User manual for the AIFEN-F4 1000W intelligent hot air rework station. Includes specifications, operation instructions, safety guidelines, and maintenance tips.
Preview AIFEN-A5 Soldering Station User Manual and Guide
User manual for the AIFEN-A5 Soldering Station, detailing its features, temperature controls, standby settings, and compatibility with JBC C210/C245/C115 soldering tips for electronic rework.
Preview AIFEN A9/A9PRO SMD Soldering Station User Manual
Comprehensive user manual for the AIFEN A9 and A9PRO SMD Soldering Station, covering safety guidelines, product features, operation instructions, maintenance, and specifications.
Preview AiXun HT316 2-In-1 Hot Air Rework Station Overview
Detailed overview and specifications for the AiXun HT316 2-in-1 Hot Air Rework Station, featuring dual-channel precision soldering, gesture control, and smart connectivity.
Preview YIHUA 2009D-I Hot Air Rework Station ESD Safe Operation Manual
Operation manual for the YIHUA 2009D-I Hot Air Rework Station. Covers applications, control panel, operations, maintenance, troubleshooting, and nozzle specifications for ESD-safe electronic rework.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.