1. Introduction
The TTNergy Hybrid Solar Inverter is a multi-function inverter/charger designed to provide uninterruptible power support for your home or solar power system. It combines the functions of an inverter, solar charger, and battery charger into a portable and efficient unit. This manual provides essential information for the safe and effective installation, operation, and maintenance of your inverter.
Key Features:
- Customizable status LED ring with RGB lights
- Touchable button interface with a 4.3" colored LCD display
- Supports USB On-the-Go (OTG) function
- Data logging of events stored within the inverter
- Capable of self-consumption and feeding excess power back to the grid
- Programmable supply priority for PV, Battery, or Grid sources
- User-adjustable charging current and voltage settings
- Multiple programmable operation modes: Grid-tie, Off-grid, and Grid-tie with backup
- Built-in Wi-Fi for convenient mobile monitoring (App available)
- Reserved communication port for Battery Management System (BMS) integration
- Parallel operation capability for up to 9 units to expand system capacity
2. Product Overview and Components
Familiarize yourself with the inverter's physical layout and connection points before installation.

Figure 2.1: Product Overview and Dimensions

Figure 2.2: Rear Panel Connections
- AC input connectors
- Circuit breaker
- AC output connectors
- Battery connectors
- Power switch
- PV connectors
- Dry contact
- USB communication port
- RS-232 communication port
- BMS communication port: CAN, RS-485 or RS-232
3. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Please consult a qualified electrician for installation if you are unsure.
3.1 System Diagram
The inverter integrates various power sources and loads. Below is a general system diagram illustrating typical connections.

Figure 3.1: Hybrid Solar Inverter System Diagram
3.2 PV Connection
Connect your solar PV modules to the inverter's PV input. Ensure correct polarity and voltage parameters.

Figure 3.2: PV Connection Diagram
When selecting proper PV modules, ensure the following parameters are considered:
- Open circuit voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter.
- Open circuit voltage (Voc) of PV modules should be higher than min. battery voltage.
3.3 Battery Connection
Connect the battery bank to the inverter's battery connectors. Ensure correct polarity and secure connections.

Figure 3.3: Battery Connection Diagram
The 5.6KW model supports a 48VDC system model.
3.4 Communication Connection
The inverter offers various communication ports for monitoring and control.

Figure 3.4: Communication Connection Diagram
Available communication ports include USB, RS232, RS485, WIFI, and Dry-contact.
4. Operating Instructions
The inverter features a comprehensive LCD display and touchable buttons for user-configurable settings and monitoring.
4.1 Powering On/Off
Use the main power switch (labeled '5' in Figure 2.2) to turn the inverter ON or OFF.
4.2 Operation Modes
The inverter supports multiple operation modes, which can be configured via the LCD interface:
- Grid-tie: Inverter synchronizes with the utility grid, feeding excess solar power back.
- Off-grid: Inverter operates independently from the utility grid, typically powered by solar and batteries.
- Grid-tie with backup: Inverter primarily operates in grid-tie mode but can switch to battery backup during grid outages.
4.3 Transfer Time
The inverter features a rapid transfer time to ensure minimal interruption to connected loads:
- For Personal Computers: 10ms
- For Home Appliances: 20ms
4.4 Monitoring
The built-in Wi-Fi module allows for mobile monitoring via a dedicated application. Connect your inverter to your local Wi-Fi network and download the app for remote access to system status and data.
5. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter.
- Keep the inverter's ventilation openings clear of dust and debris to prevent overheating.
- Periodically check all electrical connections for tightness and signs of corrosion.
- Ensure the operating environment remains within the specified temperature and humidity ranges.
- Clean the exterior of the inverter with a dry cloth. Do not use liquid cleaners.
6. Troubleshooting
This section provides general guidance for common issues. For complex problems, please contact customer support.
- No Power Output: Check the circuit breaker (labeled '2' in Figure 2.2) and ensure the power switch is ON. Verify battery and PV connections.
- Inverter Overheating: Ensure adequate ventilation around the unit. Check for blocked air vents. Reduce load if necessary.
- Abnormal Display Readings: Refer to the inverter's LCD display for error codes or warning messages. Consult the full manual (if available) or contact support with the specific code.
- Communication Issues: Verify Wi-Fi connection, USB/RS232/RS485 cable connections, and ensure monitoring software/app is correctly configured.
7. Specifications
Detailed technical specifications for the TTNergy Hybrid Solar Inverter.

Figure 7.1: Inverter Features and System Diagrams
| Feature | TTN-MKS-IV 3.6KW | TTN-MKS-IV 5.6KW |
|---|---|---|
| Phase | 1-phase in / 1-phase out | |
| Maximum PV Input Power | 5000W | 6000W |
| Rated Output Power | 3600W | 5600W |
| Maximum Charging Power | 5000W | 6000W |
| GRID-TIE OPERATION - PV INPUT (DC) | ||
| Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | 360 VDC / 450 VDC |
| Start-up Voltage / Initial Feeding Voltage | 110VDC / 120 VDC | |
| MPP Voltage Range | 120 VDC ~ 430 VDC | |
| Number of MPP Trackers / Maximum Input Current | 1 / 18 A | 1 / 27 A |
| GRID-TIE OPERATION - GRID OUTPUT (AC) | ||
| Nominal Output Voltage | 220/230/240 VAC | |
| Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC (Selectable) | |
| Nominal Output Current | 15.6A | 24.3A |
| Power Factor | > 0.9 | |
| EFFICIENCY | ||
| Maximum Conversion Efficiency (DC/AC) | 96% | |
| OFF-GRID OPERATION - AC INPUT | ||
| AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | |
| Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC | |
| Maximum AC Input Current | 40 A | |
| OFF-GRID OPERATION - PV INPUT (DC) | ||
| Maximum DC Voltage | 500 VDC | 450 VDC |
| MPP Voltage Range | 120 VDC ~ 430 VDC | |
| Number of MPP Trackers / Maximum Input Current | 1 / 18 A | 1 / 27 A |
| OFF-GRID OPERATION - BATTERY MODE OUTPUT (AC) | ||
| Nominal Output Voltage | 220/230/240 VAC | |
| Output Waveform | Pure sinewave | |
| Efficiency (DC to AC) | 93% | |
| BATTERY & CHARGER | ||
| Nominal DC Voltage | 48 VDC | |
| Maximum Solar Charging Current | 100A | 120A |
| Maximum AC Charging Current | 100A | 120A |
| Maximum Charging Current | 100A | 120A |
| GENERAL - PHYSICAL | ||
| Dimension, D x W x H (mm) | 140 x 295 x 468 | |
| Net Weight (kgs) | 11 | 12 |
| GENERAL - INTERFACE | ||
| Parallel Function | Yes, 9 units | |
| Communication Port | USB/RS232/RS485/WIFI/Dry-contact | |
| GENERAL - ENVIRONMENT | ||
| Humidity | 0 ~ 90% RH (Non-condensing) | |
| Operating Temperature | -10 to 50ºC | |
8. User Tips
Consider the following advice for optimal performance and system longevity:
- Battery Capacity Matching: The correct battery capacity for your system should be determined based on the specific load requirements and application scenarios. Incorrect sizing can lead to insufficient power or wasted generation capacity. Refer to the full manual for detailed recommendations or consult with a solar energy professional.
9. Warranty and Support
The TTNergy Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase.
For technical support, troubleshooting assistance, or warranty claims, please contact your seller or the manufacturer directly. Ensure you have your product model and purchase details available when seeking support.