EARU EASEM-F-EWE

Contents

User Manual: eWeLink Smart WiFi Power Energy Meter with CT Clamp

Model: EASEM-F-EWE | Brand: EARU

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your EARU eWeLink Smart WiFi Power Energy Meter with CT Clamp. This device is designed to monitor electricity consumption, offer remote control capabilities, and provide protection features for your electrical circuits. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

2. Safety Information

  • Ensure all wiring is performed by a qualified electrician to prevent electric shock or fire hazards.
  • Disconnect power before installation or maintenance.
  • Do not operate the device in wet or damp conditions.
  • Verify that the power supply voltage matches the device's rated voltage (AC100-240V).
  • The module's dry contact has a maximum load current rating of 10A. If controlling loads exceeding 10A, a contactor must be added.
  • When using a 110V power supply, set the Under-Voltage protection to 110V in the app to prevent the device from powering on unexpectedly.

3. Product Overview

The EARU Smart WiFi Power Energy Meter is a compact device designed for DIN rail installation, featuring an integrated LED indicator and terminals for AC input, neutral, and switch control. It comes with a Current Transformer (CT) clamp for non-invasive current measurement.

3.1 Components

eWeLink Smart WiFi Power Energy Meter with CT Clamp and smartphone app interface

Image: The main unit of the power energy meter, a CT clamp, and a smartphone displaying the eWeLink app interface for monitoring and control.

3.2 Dimensions

Dimensions of the power energy meter and CT clamp

Image: Detailed dimensions of the main meter unit (46x46x19mm) and the CT clamp, indicating it's designed for 35mm DIN rail installation.

3.3 Key Functions

  • Current Limit (0.1A-70A Adjustable)
  • Min. Power (0.1W-15000W Adjustable)
  • Max. Power (1W-15000W Adjustable)
  • Min. Voltage (0.1V-240V Adjustable)
  • Max. Voltage (1V-240V Adjustable)
  • Energy Monitor
  • Timer Switch
  • Remote Control ON/OFF
  • Power Failure Memory
  • On-Off Function
Icons representing various functions of the smart energy meter

Image: Visual representation of the device's functions including Remote Control, On-Off, Under Voltage Protection, Timer Switch, Energy Monitor, Wattage Protection, Current Limit, Prepaid Function, and Power off Memory.

4. Specifications

AttributeValue
Brand NameEARU
Model NumberEASEM-F-EWE
Dimensions46*46*19MM
Operating Temperature-10~55℃
Working VoltageAC100-240V
Frequency50/60Hz
Accuracy Class±2%
Measuring Energy Range999999.99kWh
Phasesingle phase
Rated Current80A/120A/200A/300A (Note: The device's current is determined by the current transformer, not by the host. The rated current indicated on the host can be disregarded for reference.)
Max Operating Current150A & Above
Rated Voltage240V
Power SupplyAC
Display TypeDigital Only
DIY SuppliesElectrical
OriginMainland China
CertificationCE
Min. Power0.1W-15000W
Max. Power1W-15000W
Min. Voltage0.1V-240V
Max. Voltage1V-240V
Max. Current0.1A-70A
AppeWeLink
Installation35MM Din Rail
ProtocolWiFi 2.4GHz Only (5GHz Not Supported)
FunctionsOn/Off Switch, Timer Relay Switch, Voltmeter, Ammeter, Power Meter, Current Limit, Share, Voice Control, Power Failure Memory

5. Setup and Installation

5.1 Physical Installation

The device is designed for 35MM Din Rail installation. Mount the main unit securely onto a standard DIN rail within your electrical box.

Installation schematic showing the power meter on a DIN rail connected to an air switch and fuses

Image: Installation schematic. The power meter is mounted on a 35mm DIN rail and connected to an air switch and fuses. Ensure the POW Elite is connected behind the air switch, not directly to the grid.

5.2 Wiring Instructions

Follow the wiring diagrams carefully. It is recommended that a qualified electrician performs the installation.

Wiring diagram for the smart energy meter to power grid and sockets

Image: Wiring instructions showing connections from the power grid to the meter, and then to sockets. To enter network connection mode, press and hold the reset button for 5 seconds until the green light flashes quickly.

Wiring diagram for the smart energy meter with a contactor

Image: Wiring instructions for connecting the smart energy meter with a contactor, suitable for loads exceeding 10A. The CT clamp is shown connected to the circuit breaker.

5.3 Current Transformer (CT) Clamp Installation

The CT clamp measures the current. It supports bidirectional sensing.

  1. Open the clip to see arrows (P1→ P2) or (K→ L). You can also find this on the sticker outside the clip. This indicates the direction of the CT. If the direction of the CT is opposite, the power reading will be negative.
  2. According to the wiring diagram, connect the AC input line to the socket near the electrical box to supply power to the power clamp. Apply the CT to the cable, ensuring the direction of the CT is correct for your installation.
Diagram showing CT clamp dimensions and direction of current flow

Image: Diagram illustrating the CT clamp's physical dimensions (Model 80A, 120A, 200A, 300A with corresponding Φ, A, B, C, D, E measurements) and the correct direction for current sensing (P1 to P2 or K to L).

5.4 App Installation and Device Pairing

The device uses the eWeLink app for smart control. It supports WiFi 2.4GHz only (5GHz is not supported).

  1. Download the eWeLink app from your device's app store (Android/iOS).
  2. Open the app and register/log in.
  3. To add a device, press and hold the reset button on the meter for 5 seconds until the green LED indicator flashes quickly. This puts the device into pairing mode.
  4. In the eWeLink app, tap the "+" icon to add a device. Follow the on-screen prompts to connect to your 2.4GHz WiFi network and complete the pairing process.

Video: A demonstration of the eWeLink Smart WiFi Power Energy Meter, showing its physical components (meter and CT clamp) and the process of pairing it with the eWeLink mobile application. The video illustrates adding the device, confirming network settings, and successful device detection and addition within the app.

6. Operating Instructions

Once installed and paired with the eWeLink app, you can access various functions.

Screenshots of the eWeLink app showing various settings and monitoring features

Image: Multiple screenshots of the eWeLink app interface, demonstrating features like consumption monitoring, scheduling, timers, loop timers, and device settings including OPS (Over/Under Protection Settings) and cost management.

6.1 Remote Control ON/OFF

Use the main switch icon in the eWeLink app to remotely turn the connected load ON or OFF.

6.2 Energy Monitoring

The app provides real-time monitoring of kWh, voltage, current, and power consumption. You can view electricity usage data by year, month, day, and hour.

Real-time electricity monitoring in the eWeLink app

Image: A visual of the eWeLink app displaying real-time monitoring of kWh, voltage, current, and power consumption, with historical data records.

6.3 Timer and Schedule Functions

Set schedules and timers for automatic ON/OFF operations.

  • Countdown Mode: Set a countdown timer for the device to turn off after a specified duration (e.g., turn off bedroom light after 10 minutes).
  • Timed Mode: Schedule specific ON/OFF times (e.g., turn on living room light at 18:00).
  • Recurring Timer Mode: Set repeating schedules for daily or weekly operations (e.g., turn on living room light at 6:00 and turn off at 8:00).
Examples of countdown, timed, and recurring timer modes in a smart home setting

Image: Visual examples of Countdown Mode (turn off bedroom light after 10 minutes), Timed Mode (turn on living room light at 18:00), and Recurring Timer Mode (turn on living room light at 6:00/turn off at 8:00).

6.4 Alarm Settings (Over/Under Protection)

Configure thresholds for power, voltage, and current to protect your appliances. If any set condition is met, the device will automatically turn itself off.

eWeLink app interface for setting alarm thresholds for power, voltage, and current

Image: Screenshots of the eWeLink app showing the "Alarm Setting" interface where users can set minimum and maximum thresholds for power (0.1W-15000W), voltage (0.1V-240V), and current (0.1A-70A). Each setting has a "Tripping Switch" to enable/disable the protection.

Important Note for 110V Power Supply:

If using a 110V power supply, you must set the Min. Voltage protection to 110V in the app. Failure to do so will prevent the device from powering on correctly.

6.5 Prepaid Function

Set a daily or monthly electricity consumption goal. If the goal is exceeded, the device can automatically turn off connected appliances to help reduce electricity bills.

eWeLink app interface showing the Prepaid Function for cost management

Image: The eWeLink app's "Cost Management" screen, illustrating features like Electricity Balance Monitor, Remaining Balance, Preset Electricity, Set Electricity Records, Reset Remaining Electricity, and Insufficient Electricity Balance Notice. This enables the prepaid function.

Smartphone displaying a push notification for exceeding power consumption goal

Image: A smartphone screen showing a push notification from the eWeLink app, indicating that the power consumption goal (e.g., 20kWh) has been reached, allowing users to manage their usage.

6.6 Voice Control

Integrate with Amazon Alexa or Google Home to control your devices using voice commands.

Voice control integration with Amazon Alexa and Google Home

Image: Illustration of voice control functionality, showing Amazon Alexa and Google Home devices responding to commands like "Alexa/Google, Turn On The Living Room Light."

6.7 Power Failure Memory Mode

The device automatically saves your consumption data even during power outages. Data can be kept for up to 6 months and exported to Excel on your phone.

eWeLink app interface for Power-on State settings

Image: The eWeLink app's "Power-on State" setting, allowing users to configure the device's behavior after a power failure (ON, OFF, or Last state).

7. User Tips

  • For accurate current readings, ensure the CT clamp is installed with the correct direction (P1 to P2 or K to L). If readings are negative, reverse the CT clamp.
  • Regularly check the eWeLink app for firmware updates to ensure optimal performance and access to new features.
  • Utilize the scheduling and automation features to save energy and enhance convenience.
  • If experiencing connectivity issues, ensure your WiFi network is 2.4GHz and the signal strength is adequate at the device's location.

8. Troubleshooting

  • Device not powering on: Check power connections. If using 110V, ensure Min. Voltage protection is set to 110V in the app.
  • Cannot connect to WiFi: Ensure your WiFi is 2.4GHz. Reset the device to pairing mode (hold reset button for 5 seconds) and try pairing again. Check WiFi password.
  • Incorrect current readings: Verify the CT clamp direction. If the power reading is negative, reverse the CT clamp.
  • Device turns off unexpectedly: Check alarm settings (Min/Max Power, Voltage, Current) in the app. Adjust thresholds if necessary.
  • Controlling high loads: If the load exceeds 10A, ensure a contactor is properly installed and wired.

9. Maintenance

  • Keep the device clean and free from dust.
  • Avoid exposing the device to extreme temperatures or humidity.
  • Periodically check wiring connections for tightness and signs of wear.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.