1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your EARU eWeLink Smart WiFi Power Energy Meter with CT Clamp. This device is designed to monitor electricity consumption, offer remote control capabilities, and provide protection features for your electrical circuits. Please read this manual thoroughly before using the product to ensure safe and efficient operation.
2. Safety Information
- Ensure all wiring is performed by a qualified electrician to prevent electric shock or fire hazards.
- Disconnect power before installation or maintenance.
- Do not operate the device in wet or damp conditions.
- Verify that the power supply voltage matches the device's rated voltage (AC100-240V).
- The module's dry contact has a maximum load current rating of 10A. If controlling loads exceeding 10A, a contactor must be added.
- When using a 110V power supply, set the Under-Voltage protection to 110V in the app to prevent the device from powering on unexpectedly.
3. Product Overview
The EARU Smart WiFi Power Energy Meter is a compact device designed for DIN rail installation, featuring an integrated LED indicator and terminals for AC input, neutral, and switch control. It comes with a Current Transformer (CT) clamp for non-invasive current measurement.
3.1 Components

Image: The main unit of the power energy meter, a CT clamp, and a smartphone displaying the eWeLink app interface for monitoring and control.
3.2 Dimensions

Image: Detailed dimensions of the main meter unit (46x46x19mm) and the CT clamp, indicating it's designed for 35mm DIN rail installation.
3.3 Key Functions
- Current Limit (0.1A-70A Adjustable)
- Min. Power (0.1W-15000W Adjustable)
- Max. Power (1W-15000W Adjustable)
- Min. Voltage (0.1V-240V Adjustable)
- Max. Voltage (1V-240V Adjustable)
- Energy Monitor
- Timer Switch
- Remote Control ON/OFF
- Power Failure Memory
- On-Off Function

Image: Visual representation of the device's functions including Remote Control, On-Off, Under Voltage Protection, Timer Switch, Energy Monitor, Wattage Protection, Current Limit, Prepaid Function, and Power off Memory.
4. Specifications
| Attribute | Value |
|---|---|
| Brand Name | EARU |
| Model Number | EASEM-F-EWE |
| Dimensions | 46*46*19MM |
| Operating Temperature | -10~55℃ |
| Working Voltage | AC100-240V |
| Frequency | 50/60Hz |
| Accuracy Class | ±2% |
| Measuring Energy Range | 999999.99kWh |
| Phase | single phase |
| Rated Current | 80A/120A/200A/300A (Note: The device's current is determined by the current transformer, not by the host. The rated current indicated on the host can be disregarded for reference.) |
| Max Operating Current | 150A & Above |
| Rated Voltage | 240V |
| Power Supply | AC |
| Display Type | Digital Only |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | CE |
| Min. Power | 0.1W-15000W |
| Max. Power | 1W-15000W |
| Min. Voltage | 0.1V-240V |
| Max. Voltage | 1V-240V |
| Max. Current | 0.1A-70A |
| App | eWeLink |
| Installation | 35MM Din Rail |
| Protocol | WiFi 2.4GHz Only (5GHz Not Supported) |
| Functions | On/Off Switch, Timer Relay Switch, Voltmeter, Ammeter, Power Meter, Current Limit, Share, Voice Control, Power Failure Memory |
5. Setup and Installation
5.1 Physical Installation
The device is designed for 35MM Din Rail installation. Mount the main unit securely onto a standard DIN rail within your electrical box.

Image: Installation schematic. The power meter is mounted on a 35mm DIN rail and connected to an air switch and fuses. Ensure the POW Elite is connected behind the air switch, not directly to the grid.
5.2 Wiring Instructions
Follow the wiring diagrams carefully. It is recommended that a qualified electrician performs the installation.

Image: Wiring instructions showing connections from the power grid to the meter, and then to sockets. To enter network connection mode, press and hold the reset button for 5 seconds until the green light flashes quickly.

Image: Wiring instructions for connecting the smart energy meter with a contactor, suitable for loads exceeding 10A. The CT clamp is shown connected to the circuit breaker.
5.3 Current Transformer (CT) Clamp Installation
The CT clamp measures the current. It supports bidirectional sensing.
- Open the clip to see arrows (P1→ P2) or (K→ L). You can also find this on the sticker outside the clip. This indicates the direction of the CT. If the direction of the CT is opposite, the power reading will be negative.
- According to the wiring diagram, connect the AC input line to the socket near the electrical box to supply power to the power clamp. Apply the CT to the cable, ensuring the direction of the CT is correct for your installation.

Image: Diagram illustrating the CT clamp's physical dimensions (Model 80A, 120A, 200A, 300A with corresponding Φ, A, B, C, D, E measurements) and the correct direction for current sensing (P1 to P2 or K to L).
5.4 App Installation and Device Pairing
The device uses the eWeLink app for smart control. It supports WiFi 2.4GHz only (5GHz is not supported).
- Download the eWeLink app from your device's app store (Android/iOS).
- Open the app and register/log in.
- To add a device, press and hold the reset button on the meter for 5 seconds until the green LED indicator flashes quickly. This puts the device into pairing mode.
- In the eWeLink app, tap the "+" icon to add a device. Follow the on-screen prompts to connect to your 2.4GHz WiFi network and complete the pairing process.
Video: A demonstration of the eWeLink Smart WiFi Power Energy Meter, showing its physical components (meter and CT clamp) and the process of pairing it with the eWeLink mobile application. The video illustrates adding the device, confirming network settings, and successful device detection and addition within the app.
6. Operating Instructions
Once installed and paired with the eWeLink app, you can access various functions.

Image: Multiple screenshots of the eWeLink app interface, demonstrating features like consumption monitoring, scheduling, timers, loop timers, and device settings including OPS (Over/Under Protection Settings) and cost management.
6.1 Remote Control ON/OFF
Use the main switch icon in the eWeLink app to remotely turn the connected load ON or OFF.
6.2 Energy Monitoring
The app provides real-time monitoring of kWh, voltage, current, and power consumption. You can view electricity usage data by year, month, day, and hour.

Image: A visual of the eWeLink app displaying real-time monitoring of kWh, voltage, current, and power consumption, with historical data records.
6.3 Timer and Schedule Functions
Set schedules and timers for automatic ON/OFF operations.
- Countdown Mode: Set a countdown timer for the device to turn off after a specified duration (e.g., turn off bedroom light after 10 minutes).
- Timed Mode: Schedule specific ON/OFF times (e.g., turn on living room light at 18:00).
- Recurring Timer Mode: Set repeating schedules for daily or weekly operations (e.g., turn on living room light at 6:00 and turn off at 8:00).

Image: Visual examples of Countdown Mode (turn off bedroom light after 10 minutes), Timed Mode (turn on living room light at 18:00), and Recurring Timer Mode (turn on living room light at 6:00/turn off at 8:00).
6.4 Alarm Settings (Over/Under Protection)
Configure thresholds for power, voltage, and current to protect your appliances. If any set condition is met, the device will automatically turn itself off.

Image: Screenshots of the eWeLink app showing the "Alarm Setting" interface where users can set minimum and maximum thresholds for power (0.1W-15000W), voltage (0.1V-240V), and current (0.1A-70A). Each setting has a "Tripping Switch" to enable/disable the protection.
Important Note for 110V Power Supply:
If using a 110V power supply, you must set the Min. Voltage protection to 110V in the app. Failure to do so will prevent the device from powering on correctly.
6.5 Prepaid Function
Set a daily or monthly electricity consumption goal. If the goal is exceeded, the device can automatically turn off connected appliances to help reduce electricity bills.

Image: The eWeLink app's "Cost Management" screen, illustrating features like Electricity Balance Monitor, Remaining Balance, Preset Electricity, Set Electricity Records, Reset Remaining Electricity, and Insufficient Electricity Balance Notice. This enables the prepaid function.

Image: A smartphone screen showing a push notification from the eWeLink app, indicating that the power consumption goal (e.g., 20kWh) has been reached, allowing users to manage their usage.
6.6 Voice Control
Integrate with Amazon Alexa or Google Home to control your devices using voice commands.

Image: Illustration of voice control functionality, showing Amazon Alexa and Google Home devices responding to commands like "Alexa/Google, Turn On The Living Room Light."
6.7 Power Failure Memory Mode
The device automatically saves your consumption data even during power outages. Data can be kept for up to 6 months and exported to Excel on your phone.

Image: The eWeLink app's "Power-on State" setting, allowing users to configure the device's behavior after a power failure (ON, OFF, or Last state).
7. User Tips
- For accurate current readings, ensure the CT clamp is installed with the correct direction (P1 to P2 or K to L). If readings are negative, reverse the CT clamp.
- Regularly check the eWeLink app for firmware updates to ensure optimal performance and access to new features.
- Utilize the scheduling and automation features to save energy and enhance convenience.
- If experiencing connectivity issues, ensure your WiFi network is 2.4GHz and the signal strength is adequate at the device's location.
8. Troubleshooting
- Device not powering on: Check power connections. If using 110V, ensure Min. Voltage protection is set to 110V in the app.
- Cannot connect to WiFi: Ensure your WiFi is 2.4GHz. Reset the device to pairing mode (hold reset button for 5 seconds) and try pairing again. Check WiFi password.
- Incorrect current readings: Verify the CT clamp direction. If the power reading is negative, reverse the CT clamp.
- Device turns off unexpectedly: Check alarm settings (Min/Max Power, Voltage, Current) in the app. Adjust thresholds if necessary.
- Controlling high loads: If the load exceeds 10A, ensure a contactor is properly installed and wired.
9. Maintenance
- Keep the device clean and free from dust.
- Avoid exposing the device to extreme temperatures or humidity.
- Periodically check wiring connections for tightness and signs of wear.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase.