JUNO JHBM-4

Contents

JHBM-4 JUNO Ring Weighing Load Cell

Instruction Manual

1. Introduction

The JHBM-4 JUNO Ring Weighing Load Cell is a high-precision and stable sensor designed for accurate force measurement. It is suitable for a wide range of applications requiring the detection of weight, bolt preload, and pressure, particularly where a through-hole design is beneficial. This manual provides essential information for the proper setup, operation, and maintenance of your JHBM-4 load cell.

JHBM-4 JUNO Ring Weighing Load Cell with text 'High precision' and 'High stability'
Figure 1: JHBM-4 JUNO Ring Weighing Load Cell overview, highlighting high precision and stability.

2. Product Features

  • High Stability and Reliability: Engineered for consistent and dependable performance in demanding environments.
  • High Precision: Provides accurate measurement results.
  • Durable Construction: Made from stainless steel for robustness and longevity.
  • Quality Manufacturing: Adheres to a strict quality management system (ISO9001:2015 certified), ensuring linear performance, repeatability, and hysteresis performance.
  • Integrated Production Process: Features strict material selection, precise processing and cutting, specialized elastic body processing, and careful patch gluing.
  • Shielded Cable: Equipped with a shielding layer for enhanced signal integrity and protection against interference.
  • Versatile Application: Can be integrated with various systems including analog transmitters (0-10V, 4-20mA, 0-5V, 0-10V output), digital transmitters (RS485, RS232 output), and smart meters (220V/24V power, 4-20mA, RS485, RS232 output).
Icons representing stainless steel, good stability, and high precision
Figure 2: Key features of the JHBM-4 load cell: Stainless Steel, Good Stability, High Precision.
Diagram showing various application scenarios for the load cell
Figure 3: Application scenarios including ground scales, belt scales, industrial automation, mixing stations, scientific research, and robot arms.

3. Specifications

3.1 Technical Parameters

Table of technical parameters for the load cell
Figure 4: Technical Parameters of the JHBM-4 Load Cell.
Table 1: Technical Parameters
ParameterValueParameterValue
Range50, 100, 200, 300, 500 kg; 1, 2, 3, 5 tInput Resistance735 ±35 Ω
Sensitivity1.0~2.0 ±0.1 mV/VOutput Resistance700 ±3 Ω
Comprehensive Accuracy0.2% F·SInsulation Resistance≥2000 MΩ
Creep±0.1% F·S / 30minExcitation Voltage5~12 VDC
Non-linearity±0.1% F·SOperating Temperature Range-20~+70°C
Hysteresis Error±0.1% F·SAllowed Overload120% F·S
Repeatability Error±0.1% F·SSealing LevelIP66
Zero Temperature Coefficient±0.05% F·S / 10°CMaterialStainless Steel
CableΦ3 × 2000mm

3.2 Dimensional Specifications

Dimensional drawing and table for 0-1t, 2t, 2.5-5t ranges
Figure 5: Dimensional Drawing (mm) for 0-1t, 2t, 2.5-5t ranges.
Table 2: Dimensions for 0-1t, 2t, 2.5-5t Ranges (mm)
Range (t)ØAØBØCHH1
0~126148.598
23822171614
2.5-5t4526212018
Dimensional drawing and table for KN ranges
Figure 6: Dimensional Drawing (mm) for KN Ranges (H is 50mm for all).
Table 3: Dimensions for KN Ranges (mm)
Range (KN)ØAØBØC
12047.43117
18058.43822
22062.44224
26066.44426
33072.45129
40074.45332

4. Setup and Installation

  1. Mounting: Ensure the load cell is mounted on a stable, flat surface. The design indicates that the force should be applied to the central convex platform.
  2. Force Application: Apply the load directly to the central convex platform of the sensor. Refer to the 'Usage Force Diagram' for correct force application.
Diagram showing force being applied to the central convex platform of the load cell
Figure 7: Usage Force Diagram, illustrating force application on the central convex platform.
  1. Wiring: Connect the load cell according to the provided wiring definitions. Ensure proper shielding layer protection for the cable to prevent interference.
Wiring diagram for sensor and transmitter connections
Figure 8: Sensor and Transmitter Wiring Definition.
Table 4: Wiring Definitions
Sensor WiringTransmitter Wiring
Red: Power +Red: Power
Green: Power -Green: Common Terminal
Yellow: Signal +Yellow: Signal
White: Signal -
  1. Integration: The load cell can be integrated with various signal processing units:
    • Analog Transmitters: For 0-10V, 4-20mA, 0-5V, or 0-10V output.
    • Digital Transmitters: For RS485 or RS232 output.
    • Smart Meters: Compatible with 220V/24V power supply and 4-20mA, RS485, or RS232 output.
Diagram showing various transmitters and smart meters for integration
Figure 9: Associated use with analog transmitters, digital transmitters, and smart meters.

5. Operation

The JHBM-4 load cell operates by detecting the deformation caused by applied force on its central convex platform. The sensor converts this mechanical force into an electrical signal proportional to the applied load. Ensure the applied force is within the specified operating range and does not exceed the allowed overload of 120% F·S to prevent damage.

6. Maintenance

  • Regular Inspection: Periodically inspect the load cell and its connections for any signs of wear, damage, or corrosion.
  • Cleanliness: Keep the sensor and its surroundings clean to ensure optimal performance and prevent debris from affecting measurements.
  • Avoid Overload: Do not exceed the maximum allowed overload (120% of Full Scale) to maintain accuracy and prolong the lifespan of the sensor.
  • Cable Integrity: Check the cable for any damage to the outer sheath or shielding layer, which could affect signal quality.

7. Troubleshooting

No specific troubleshooting steps are provided in the product information. If you encounter issues, verify all connections, ensure the load is applied correctly, and check that the power supply is within the specified voltage range. If problems persist, contact customer support for assistance.

8. User Tips

No specific user tips were available from customer reviews or Q&A for this product. For best results, ensure the load cell is installed in an environment free from excessive vibration or temperature fluctuations outside its operating range. Calibrate regularly if high precision is critical for your application.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller directly. Ensure you have your product model (JHBM-4) and purchase details available when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.