1. Introduction
The JHBM-4 JUNO Ring Weighing Load Cell is a high-precision and stable sensor designed for accurate force measurement. It is suitable for a wide range of applications requiring the detection of weight, bolt preload, and pressure, particularly where a through-hole design is beneficial. This manual provides essential information for the proper setup, operation, and maintenance of your JHBM-4 load cell.

2. Product Features
- High Stability and Reliability: Engineered for consistent and dependable performance in demanding environments.
- High Precision: Provides accurate measurement results.
- Durable Construction: Made from stainless steel for robustness and longevity.
- Quality Manufacturing: Adheres to a strict quality management system (ISO9001:2015 certified), ensuring linear performance, repeatability, and hysteresis performance.
- Integrated Production Process: Features strict material selection, precise processing and cutting, specialized elastic body processing, and careful patch gluing.
- Shielded Cable: Equipped with a shielding layer for enhanced signal integrity and protection against interference.
- Versatile Application: Can be integrated with various systems including analog transmitters (0-10V, 4-20mA, 0-5V, 0-10V output), digital transmitters (RS485, RS232 output), and smart meters (220V/24V power, 4-20mA, RS485, RS232 output).


3. Specifications
3.1 Technical Parameters

| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | 50, 100, 200, 300, 500 kg; 1, 2, 3, 5 t | Input Resistance | 735 ±35 Ω |
| Sensitivity | 1.0~2.0 ±0.1 mV/V | Output Resistance | 700 ±3 Ω |
| Comprehensive Accuracy | 0.2% F·S | Insulation Resistance | ≥2000 MΩ |
| Creep | ±0.1% F·S / 30min | Excitation Voltage | 5~12 VDC |
| Non-linearity | ±0.1% F·S | Operating Temperature Range | -20~+70°C |
| Hysteresis Error | ±0.1% F·S | Allowed Overload | 120% F·S |
| Repeatability Error | ±0.1% F·S | Sealing Level | IP66 |
| Zero Temperature Coefficient | ±0.05% F·S / 10°C | Material | Stainless Steel |
| Cable | Φ3 × 2000mm |
3.2 Dimensional Specifications

| Range (t) | ØA | ØB | ØC | H | H1 |
|---|---|---|---|---|---|
| 0~1 | 26 | 14 | 8.5 | 9 | 8 |
| 2 | 38 | 22 | 17 | 16 | 14 |
| 2.5-5t | 45 | 26 | 21 | 20 | 18 |

| Range (KN) | ØA | ØB | ØC |
|---|---|---|---|
| 120 | 47.4 | 31 | 17 |
| 180 | 58.4 | 38 | 22 |
| 220 | 62.4 | 42 | 24 |
| 260 | 66.4 | 44 | 26 |
| 330 | 72.4 | 51 | 29 |
| 400 | 74.4 | 53 | 32 |
4. Setup and Installation
- Mounting: Ensure the load cell is mounted on a stable, flat surface. The design indicates that the force should be applied to the central convex platform.
- Force Application: Apply the load directly to the central convex platform of the sensor. Refer to the 'Usage Force Diagram' for correct force application.

- Wiring: Connect the load cell according to the provided wiring definitions. Ensure proper shielding layer protection for the cable to prevent interference.

| Sensor Wiring | Transmitter Wiring |
|---|---|
| Red: Power + | Red: Power |
| Green: Power - | Green: Common Terminal |
| Yellow: Signal + | Yellow: Signal |
| White: Signal - |
- Integration: The load cell can be integrated with various signal processing units:
- Analog Transmitters: For 0-10V, 4-20mA, 0-5V, or 0-10V output.
- Digital Transmitters: For RS485 or RS232 output.
- Smart Meters: Compatible with 220V/24V power supply and 4-20mA, RS485, or RS232 output.

5. Operation
The JHBM-4 load cell operates by detecting the deformation caused by applied force on its central convex platform. The sensor converts this mechanical force into an electrical signal proportional to the applied load. Ensure the applied force is within the specified operating range and does not exceed the allowed overload of 120% F·S to prevent damage.
6. Maintenance
- Regular Inspection: Periodically inspect the load cell and its connections for any signs of wear, damage, or corrosion.
- Cleanliness: Keep the sensor and its surroundings clean to ensure optimal performance and prevent debris from affecting measurements.
- Avoid Overload: Do not exceed the maximum allowed overload (120% of Full Scale) to maintain accuracy and prolong the lifespan of the sensor.
- Cable Integrity: Check the cable for any damage to the outer sheath or shielding layer, which could affect signal quality.
7. Troubleshooting
No specific troubleshooting steps are provided in the product information. If you encounter issues, verify all connections, ensure the load is applied correctly, and check that the power supply is within the specified voltage range. If problems persist, contact customer support for assistance.
8. User Tips
No specific user tips were available from customer reviews or Q&A for this product. For best results, ensure the load cell is installed in an environment free from excessive vibration or temperature fluctuations outside its operating range. Calibrate regularly if high precision is critical for your application.
9. Warranty and Support