Runxin F67Q1 55504, F67Q3 55604

Runxin Automatic Filter Valve Instruction Manual

Models: F67Q1 55504, F67Q3 55604

For Water Treatment Filter Applications

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Runxin F67Q1 55504 and F67Q3 55604 automatic filter valves. These controllers are designed for use in various water treatment filter systems, including household filtration and activated carbon filters for reverse osmosis pre-treatment. Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the product.

2. Product Overview

The Runxin automatic filter valve is a sophisticated controller integrating the main control board and display board into a single unit. It features a four-digit digital tube display for clear status indication and includes interlock, signal output, and power-off data memory functions to ensure reliable and consistent performance.

2.1 Key Features

  • Integrated main control board and display board.
  • Four-digit digital tube display for easy monitoring.
  • Interlock and signal output capabilities.
  • Power-off data memory function to retain settings during power interruptions.

2.2 Components

The valve consists of a main body with inlet, outlet, and drain ports, and an integrated control head with a digital display and control buttons.

Front view of Runxin automatic filter valve control panel
Figure 1: Front view of the Runxin automatic filter valve control panel.
Close-up of threaded inlet and outlet ports on the valve
Figure 2: Close-up view of the threaded inlet and outlet ports.

3. Specifications

The following table details the technical specifications for the Runxin F67Q1 55504 and F67Q3 55604 automatic filter valves.

Table of product features and parameters in Chinese
Figure 3: Original product features and parameters table.
ParameterSpecification
Product Model55504 (F67Q1 - Time Type), 55604 (F67Q3 - Flow Type)
Installation MethodTop-mounted
Inlet/Outlet Port1"F (Female Thread)
Drain Port1"F (Female Thread)
Installation DirectionRight in, Left out
Base2.5"-8NPSM (Tank Port)
Central Pipe1.05"OD (Outer Diameter)
Production Capacity4 m³/h
Applicable Tank Size6"-12"
Working Pressure0.15-0.6 MPa
Inlet Water Temperature5-50°C
Inlet Water Turbidity< 20 FTU
Power AdapterInput: AC100~240V/50~60HZ, Output: DC12V/1.5A
MaterialPlastic
DIY Supplies CategoryElectrical
OriginMainland China

Note: F- Female thread, M- Male thread, OD- Outer Diameter, D-GB represents national standard diameter.

4. Setup and Installation

The Runxin automatic filter valve is designed for top-mounted installation on compatible filter tanks. Ensure all connections are secure and leak-free.

4.1 Pre-installation Checklist

  • Verify that the filter tank is compatible with a 2.5"-8NPSM base and a 1.05"OD central pipe.
  • Ensure the inlet and outlet plumbing are 1"F (female thread) and align with the "Right in, Left out" flow direction.
  • Confirm that the power supply meets the requirements: Input AC100~240V/50~60HZ, Output DC12V/1.5A.
  • Inspect all components for any damage before installation.

4.2 Installation Steps

  1. Prepare the Filter Tank: Ensure the filter tank is clean and ready for valve installation. Insert the central pipe into the tank.
  2. Mount the Valve: Carefully screw the valve onto the top of the filter tank, ensuring the central pipe aligns correctly with the valve's internal mechanism. Tighten securely to prevent leaks.
  3. Connect Plumbing: Connect the water inlet pipe to the designated "IN" port (right side) and the water outlet pipe to the "OUT" port (left side). Connect the drain line to the drain port. Use appropriate thread sealant for all connections.
  4. Connect Power: Plug the DC12V/1.5A power adapter into the valve and then into a suitable electrical outlet.
  5. Initial System Check: Slowly open the main water supply to the filter system and check for any leaks.
Side view of the Runxin automatic filter valve, showing ports
Figure 4: Side view of the valve, illustrating port locations.

5. Operating Instructions

The control panel allows for monitoring and adjustment of the valve's operation. Refer to Figure 5 for button layout and display indicators.

Control panel of the Runxin automatic filter valve with Chinese labels
Figure 5: Control Panel Layout.

5.1 Control Panel Overview

  • Display: Shows "Current Time" (当前时间) and "Regeneration Time" (再生时间). The "Running Days" (运行天数) is also displayed.
  • Indicators:
    • "常亮: 查询状态" (Always on: Query status)
    • "闪烁: 按键锁住" (Flashing: Key locked)
  • Buttons:
    • Menu/Confirm (菜单 确认): Used to enter menus and confirm selections.
    • Manual/Return (手动 返回): Used for manual operations or to return to the previous screen.
    • Down (向下): Used to decrease values or navigate downwards.
    • Up (向上): Used to increase values or navigate upwards.

5.2 Unlocking the Control Panel

To unlock the control panel for adjustments:

  1. Press and hold the Up (▲) and Down (▼) buttons simultaneously for 5 seconds. The "Key locked" indicator (闪烁: 按键锁住) will stop flashing.

5.3 Querying Status

After unlocking:

  1. Press the Menu/Confirm (圆) button to enter the query status. The "Query status" indicator (常亮: 查询状态) will light up.
  2. Use the Up (▲) and Down (▼) buttons to cycle through different operational statuses.

5.4 Parameter Setting

After querying status:

  1. Press the Menu/Confirm (圆) button again to enter the parameter setting status.
  2. Use the Up (▲) and Down (▼) buttons to adjust parameters.
  3. Press Menu/Confirm (圆) to save changes and move to the next parameter, or Manual/Return (手动 返回) to exit without saving.

5.5 Operational Status Indicators (F68Q1 / F116Q1 / F67Q1)

The display will show a number corresponding to the current operational stage:

  • 1 - 表示运行 (Indicates Running): The valve is in normal service mode, filtering water.
  • 2 - 表示反洗 (Indicates Backwash): The valve is performing a backwash cycle to clean the filter media.
  • 3 - 表示吸盐 (Indicates Brine Suction): (Applicable to F68Q1/F116Q1) The valve is drawing brine solution for regeneration.
  • 4 - 表示正洗 (Indicates Fast Rinse): The valve is performing a fast rinse to flush out residual brine and prepare for service.
  • 5 - 表示补水 (Indicates Refill): (Applicable to F68Q1/F116Q1) The valve is refilling the brine tank with water.

For F67Q1 models, the primary stages are: 1-Running, 2-Backwash, 3-Fast Rinse.

The time unit for regeneration/rinse cycles is displayed in minutes.

6. Maintenance

Regular maintenance ensures the optimal performance and longevity of your Runxin automatic filter valve.

  • Regular Inspection: Periodically check the valve and connections for any signs of leaks, cracks, or wear.
  • Cleaning: Keep the exterior of the control panel clean and free from dust and debris. Use a soft, damp cloth for cleaning; avoid abrasive cleaners.
  • Power Supply: Ensure the power adapter is securely connected and free from damage.
  • Filter Media: Follow the maintenance schedule for your specific filter media (e.g., activated carbon, sand filter) as recommended by the filter manufacturer. The automatic valve will manage the regeneration cycles, but the media itself may require periodic replacement or deep cleaning.
  • Salt Level (if applicable): For models that perform brine suction (e.g., F68Q1/F116Q1), regularly check and replenish the salt level in the brine tank.

7. Troubleshooting

This section provides solutions to common issues you might encounter with your automatic filter valve. If the problem persists, contact customer support.

ProblemPossible CauseSolution
Valve not responding to button pressesControl panel is locked.Press and hold the Up (▲) and Down (▼) buttons simultaneously for 5 seconds to unlock.
No display or powerPower adapter disconnected or faulty; power outage.Check power adapter connection and wall outlet. Verify power supply.
Water leakage from connectionsLoose connections; improper thread sealant.Turn off water supply, tighten connections, and reapply thread sealant if necessary.
Filter system not regeneratingIncorrect regeneration settings; sensor issue (for flow type models); power interruption.Check programmed regeneration schedule. Ensure power is stable. Consult manual for specific model settings.

8. User Tips

No specific user tips were available from reviews or Q&A for this product. General tips for automatic filter valves include:

  • Always ensure the power supply is stable to prevent interruptions in regeneration cycles.
  • Familiarize yourself with the meaning of each operational status indicator to quickly diagnose the valve's current activity.
  • For optimal performance, adhere to the recommended maintenance schedule for your specific water treatment system.

9. Warranty and Support

Information regarding specific warranty terms and customer support contacts was not provided with the product details. Please refer to your purchase documentation or contact your retailer for warranty details and technical assistance.

Related Documents - F67Q1 55504, F67Q3 55604

Preview Runxin Multi-functional Flow Control Valve User Manual for Water Treatment Systems
Comprehensive user manual for Runxin's multi-functional flow control valves used in water treatment systems, covering installation, operation, settings, and troubleshooting for models F67Q, F71Q, F68Q, F69Q, F116Q, and F117Q.
Preview 润新多功能水处理控制阀安装与操作指南 | RUNXIN Water Treatment Control Valve Manual
温州市润新机械制造有限公司生产的RUNXIN多功能水处理控制阀(型号F67Q/F71Q/F68Q/F69Q/F116Q/F117Q系列)的安装、操作、参数设置及故障排除指南。该阀门适用于各类水处理系统,提供智能化控制,是软化、过滤、除盐等应用的高效解决方案。请仔细阅读本手册以确保正确使用。
Preview RUNXIN 水处理系统多功能控制阀 安装使用说明书
This comprehensive installation and user manual from RUNXIN provides detailed information on their Multi-functional Control Valves for Water Treatment Systems, including models F67Q, F71Q, F68Q, F69Q, F116Q, and F117Q. It covers product overview, technical specifications, installation procedures, basic settings, application scenarios, troubleshooting guides, and warranty information, ensuring optimal performance and longevity of your water treatment equipment.
Preview RUNXIN Water Treatment Control Valve Installation and Operation Manual
Comprehensive installation, operation, and troubleshooting guide for RUNXIN 53520T, 53620T, 63520T, and 63620T multi-functional control valves for water treatment systems. Covers product overview, installation, settings, operation, circuit functions, system configuration, parameter calculations, troubleshooting, and warranty.
Preview Runxin Multi-functional Flow Control Valve User Manual
Comprehensive user manual for Runxin multi-functional flow control valves, including installation, parameter settings, troubleshooting, and parts diagrams for models F67Q, F71Q, F68Q, F69Q, F116Q, and F117Q.
Preview Runxin F135/F137 Multi-functional Flow Control Valve User Manual
User manual for Runxin F135 (17610T) and F137 (17606T) multi-functional flow control valves used in water treatment systems. Provides detailed information on product overview, specifications, installation, operation, troubleshooting, and warranty.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.