1. Introduction

The NISSEI RS-102 is a versatile SWR & Power Meter designed for measuring forward and reverse power, as well as forward RF power readings across the HF/VHF bands. It supports switching between peak and average power measurements for SSB and AM transmitters (REP mode). With a measurable power range of up to 200 watts and a low insertion loss (0.3 dB or lower), this device can be permanently connected in your radio setup without significant signal degradation.

2. Package Contents

  • 1 x NISSEI RS-102 SWR & Power Meter
  • 1 x 13.8V DC Lighting Power Cable

3. Device Overview and Connections

Familiarize yourself with the front and rear panels of the RS-102 meter before making any connections.

Front Panel Controls:

Front panel of NISSEI RS-102 with labels for Display, Calibration Mode, SWR, Reflected Power, Transmitting Power, Power Range Choice, Function knob, Pointer Speed Button, and Calibration Control Knob.

Detailed view of the front panel, highlighting the display and control knobs.

  • Display: Analog meter for SWR and Power readings.
  • Function Knob (FWD, REF, CAL, SWR): Selects the measurement mode.
    • FWD: Forward Power measurement.
    • REF: Reflected Power measurement.
    • CAL: Calibration mode for SWR measurement.
    • SWR: Standing Wave Ratio measurement.
  • Range Knob (5W, 20W, 200W): Selects the maximum power range for measurement.
  • Calibration Control Knob (MIN/MAX): Used for SWR calibration.
  • Pointer Speed Button (AVG/PEP/SSB): Toggles between average power and peak envelope power (PEP) for SSB/AM signals.

Rear Panel Connections:

Rear panel of NISSEI RS-102 with labels for TX, ANT, and DC 13.8V connections.

Rear panel connections for the NISSEI RS-102.

  • TX (SO-239 M connector): Connects to the transmitting end of your radio device.
  • ANT (SO-239 M connector): Connects to your antenna or dummy load.
  • DC 13.8V: Power input for the LED backlight.

4. Setup Instructions

  1. Power Connection (for Backlight): Connect the provided 13.8V DC lighting power cable to the "DC 13.8V" input on the rear panel of the RS-102. Connect the other end to a suitable 13.8V DC power source. This powers the meter's backlight.NISSEI RS-102 display with LED backlight activated

    The meter's display with the LED backlight illuminated.

  2. Radio Connection: Connect the output of your radio transmitter to the "TX" connector on the rear panel of the RS-102 using a suitable coaxial cable (e.g., PL-259 connectors).
  3. Antenna/Load Connection: Connect your antenna system or a dummy load to the "ANT" connector on the rear panel of the RS-102 using a suitable coaxial cable.
  4. Initial Settings:
    • Set the Function Knob to "FWD" (Forward Power).
    • Set the Range Knob to an appropriate power range (e.g., "200W" if your transmitter output is high, or "20W" for lower power).

5. Operating Instructions

5.1 Measuring Forward and Reflected Power

  1. Ensure all connections are secure as described in Section 4.
  2. Set the Function Knob to "FWD".
  3. Select an appropriate power range using the Range Knob (5W, 20W, or 200W). Start with a higher range if unsure to avoid damaging the meter.
  4. Transmit a steady carrier (e.g., using FM or CW mode at low power initially). The meter will display the forward power.
  5. To measure reflected power, switch the Function Knob to "REF". The meter will now display the reflected power.

5.2 Measuring Standing Wave Ratio (SWR)

  1. Ensure all connections are secure.
  2. Set the Function Knob to "CAL".
  3. Select an appropriate power range using the Range Knob.
  4. Transmit a steady carrier.
  5. Adjust the Calibration Control Knob (MIN/MAX) until the meter needle points exactly to the "CAL" mark on the scale.
  6. While still transmitting, switch the Function Knob to "SWR". The meter will now display the SWR reading.
  7. A lower SWR reading (closer to 1:1) indicates a better match between your transmitter and antenna.

5.3 Peak Envelope Power (PEP) Measurement

For SSB and AM signals, the RS-102 can measure Peak Envelope Power (PEP).

  1. Set the Function Knob to "FWD" or "REF" as desired.
  2. Press the Pointer Speed Button to toggle between "AVG" (Average) and "PEP" (Peak Envelope Power). The meter will indicate the selected mode.
  3. When in PEP mode, the meter will respond faster to signal peaks, providing a more accurate reading for modulated signals.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the meter. Do not use abrasive cleaners or solvents.
  • Storage: Store the meter in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handling: Avoid dropping or subjecting the meter to strong impacts, as this can damage the delicate internal components and the analog meter movement.
  • No User-Serviceable Parts: The RS-102 contains no user-serviceable parts. Do not attempt to open the casing, as this may void any potential warranty and could lead to electric shock.

7. Troubleshooting

  • Meter does not light up:
    • Ensure the 13.8V DC power cable is securely connected to both the meter and a functional power source.
    • Check the power source for proper voltage output.
  • No power reading:
    • Verify that your radio is transmitting.
    • Check all coaxial cable connections between the radio, meter (TX and ANT ports), and antenna/load.
    • Ensure the Function Knob is set to "FWD" or "REF".
    • Confirm the Range Knob is set to an appropriate power range.
  • SWR reading is very high or erratic:
    • Check your antenna system for proper tuning and connection.
    • Inspect coaxial cables for damage or shorts.
    • Ensure the SWR calibration procedure (Section 5.2) was followed correctly.
    • Test with a known good dummy load to isolate issues between the radio and antenna.
  • Inaccurate readings:
    • Ensure the meter is properly calibrated for SWR.
    • Verify the selected power range matches the expected output of your transmitter.
    • Check for any external RF interference.

8. Specifications

FeatureDetail
Frequency Range1.8 - 200 MHz
Measurable Power Range1 - 200 W
Power Gear Ranges5 W, 20 W, 200 W
Maximum Power200 W
Impedance50 Ohm
Connector TypeSO-239 M connector
Product Size (L x W x H)190 x 85 x 135 mm
Product Net Weight780 g
Precision (5W Range) - Average±10%
Precision (5W Range) - Peak±15%
Precision (20-200W Range) - Average±5%
Precision (20-200W Range) - Peak±10%

9. User Tips

  • Start Low, Go Slow: When first testing a new antenna or setup, always start with the lowest power setting on your radio and the highest power range on the meter. Gradually increase power while monitoring SWR.
  • Dummy Load Testing: Keep a good quality 50-ohm dummy load handy. It's invaluable for testing your radio's output and the meter's functionality without radiating a signal.
  • Cable Quality: Use high-quality coaxial cables with proper connectors. Poor cables can introduce losses and affect SWR readings.
  • Calibration is Key: Always perform the SWR calibration step (setting to CAL and adjusting the knob) before taking an SWR reading for accuracy.
  • Backlight Use: The backlight requires external 13.8V DC power. If operating in a well-lit environment, you can conserve power by not connecting the backlight.

10. Warranty and Support