1. Introduction
Thank you for choosing the Sumry Hybrid Solar Inverter. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your inverter. Please read this manual thoroughly before installation and keep it for future reference. This inverter is designed to convert reliable, clean, and quiet AC energy to supply your off-grid living or supplement your on-grid system.
The Sumry Hybrid Solar Inverter is suitable for various applications including household, photovoltaic rooftop, RV, yacht, commercial electricity, camping, emergency electricity, solar light, and agricultural electricity.

The inverter supports a wide range of applications from outdoor use to commercial electricity.
2. Safety Instructions
Please observe all warnings and cautions in this manual. Installation should only be performed by qualified personnel. Ensure proper grounding and disconnect all power sources before servicing.
- Do not disassemble the inverter.
- Keep the inverter away from flammable materials.
- Ensure adequate ventilation around the inverter.
- Avoid exposing the inverter to direct sunlight or moisture.
- Always wear appropriate personal protective equipment (PPE) during installation and maintenance.
3. Package Contents
Upon receiving your Sumry Hybrid Solar Inverter, please check the package for the following items:
- Sumry Hybrid Solar Inverter Unit (ECO LV 3.6KW or HGX 4KW model)
- User Manual
- Free WiFi Module (shipped separately from China, tracking number available from customer service)
- Necessary connection cables and accessories
If any items are missing or damaged, please contact your vendor immediately.

The inverter comes with a free WiFi module for remote monitoring.
4. Product Overview
The Sumry Hybrid Solar Inverter is a high-efficiency pure sine wave inverter designed for both on-grid (ECO LV) and off-grid (HGX) applications. It features an integrated MPPT solar charge controller and offers multiple charging and output modes to suit various energy needs.
Key Features:
- Pure Sine Wave Output: Provides clean and stable AC power, compatible with over 98% of electrical appliances.
- High MPPT Efficiency: Maximizes solar power harvest with up to 99.9% MPPT efficiency.
- Battery-less Operation: Capable of powering loads directly from the PV array without a connected battery.
- Intelligent Protection System: Includes 15 protection modes such as overload, short circuit, battery overcharge/discharge, overheating, overcurrent, high/low voltage, anti-reverse, and energy fallout protection.
- Smart Cooling: Built-in sensor chip intelligently adjusts fan speed based on ambient temperature.
- Communication: RS232/RS485 communication port and optional WiFi/GPRS module for remote monitoring.

Pure Sine Wave output ensures high compatibility and stability for sensitive electronics.

The inverter features 15 intelligent protection modes for enhanced safety and reliability.

Intelligent cooling fan adjusts speed based on temperature to maintain optimal performance.
5. Installation
Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines carefully.
5.1 Mounting the Inverter
- Choose a dry, well-ventilated area, away from direct sunlight and heat sources.
- Ensure sufficient clearance around the inverter for proper airflow.
- Mount the inverter vertically on a sturdy surface.
5.2 Wiring Connections
Before making any connections, ensure all power sources (solar panels, battery, AC input) are disconnected. It is recommended to install 4 circuit breakers in the following positions:
- Between the battery pack and the inverter battery input.
- Between the solar panel and the photovoltaic input of the inverter.
- Between the power input of the grid and the inverter.
- Between inverter output and load.
The circuit breaker is essential to prevent misconnection or reverse connection of the mains input and the inverter output. In case of a short circuit, load short circuit, or overload in the output, the circuit breaker will directly cut off the circuit to protect the inverter.

Detailed wiring diagram showing AC input, AC output, PV input, and Battery connections. Note the suggested cable and breaker sizes.

Diagram illustrating the recommended placement of circuit breakers for safety.

Close-up view of the inverter's connection ports: Battery input, AC output, RS458/RS232 communication port, AC input, PV input.
5.3 Initial Startup
After all connections are securely made and checked, you can proceed with the initial startup. Refer to the LCD display for status indicators and settings.
Video demonstrating the unboxing, connection, and operation of the Sumry Hybrid Solar Inverter, including powering a phone and a kettle.
6. Operating Modes
The inverter supports various operating modes to optimize power usage based on your preferences and available energy sources.
6.1 Charging Modes (ECO LV)
The ECO LV model offers three safe charging modes:
- Solar First: Prioritizes solar power for charging batteries and supplying loads.
- Solar and Utility: Uses solar power primarily, supplementing with utility power when solar is insufficient.
- Only Solar: Charges batteries and powers loads exclusively from solar energy.
6.2 Output Modes (ECO LV)
The ECO LV model features two output modes:
- SUB (Solar-Utility-Battery): Prioritizes solar, then utility, then battery for powering loads.
- SBU (Solar-Battery-Utility): Prioritizes solar, then battery, then utility for powering loads.
6.3 Working Modes (HGX)
The HGX model offers four working modes:
- Solar Charging: Charges batteries from solar panels.
- Electricity Utility Priority: Prioritizes utility power for loads, using solar/battery as backup.
- Solar Priority: Prioritizes solar power for loads, using utility/battery as backup.
- Hybrid Charging: Combines solar and utility power for charging and loads.

Diagram illustrating the three input charging modes and two output modes for the ECO LV series.

Diagram illustrating the four working modes and dual load output modes for the HGX series.
7. Battery Compatibility
The Sumry Hybrid Solar Inverter is compatible with most 24V battery types, including GEL, Lithium (LiFePo4), AGM, and user-defined settings (FLD). It also supports battery-less operation, allowing you to power loads directly from your PV array.

The inverter supports 24V GEL, FLD, LI, and USER battery types.

The inverter can power loads from PV arrays without a battery and is compatible with GEL, LI, AGM, USER, and FLD battery types.
8. Specifications
Below are the detailed specifications for the Sumry Hybrid Solar Inverter models ECO LV 3.6KW PLUS and HGX (110V) 4KW.
| Feature | VICTOR NM-ECO-LV-3.6KW PLUS | HGX (110V) 4KW |
|---|---|---|
| Rated Power | 3600VA/3600W | 4000W |
| Max PV Input Power | 4200W | Not specified (140A MPPT, Max PV 5600W charger) |
| Max Solar Charging Current | 120A | 110A |
| Nominal DC Voltage (Battery) | 24VDC | 24VDC |
| MPPT Voltage Range | 60-450VDC | 55Vdc-280Vdc |
| AC Output Voltage | 120VAC (100/105/115V settable) | 120VAC ±5% |
| Output Wave Form | Pure Sine Wave | Pure Sine Wave |
| Max AC Input Current | 40A | Not specified (40A/80A in wiring diagram) |
| Efficiency (DC/AC) | 98% | 98% |
| MPPT Efficiency | Not specified (>99.9% in diagram) | 99.90% |
| Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERY | COM port (Standard), LCD remote/WiFi (Optional) |
| Dimensions (H*W*D) | 420*350*110 mm | Not specified (40*25*8.9cm in product props) |
| Net Weight | 8.8 kg | 9 kg (from product props) |
| Operating Temperature | -15°C~50°C | Not specified |
| Compliance Safety | CE | CE |
Note: Some specifications may vary slightly between models or production batches. Always refer to the product label for the most accurate information.

Detailed data sheet for the VICTOR NM-ECO-LV-3.6KW PLUS model.

Detailed data sheet for the HGX (110V) 4KW model.
9. Troubleshooting
This section addresses common issues you might encounter with your Sumry Hybrid Solar Inverter.
Common Issues & Solutions:
- No Power Output: Check all connections, ensure batteries are charged, and verify solar panel input. Check circuit breakers.
- Inverter Overheating: Ensure adequate ventilation around the unit. Clean any dust from the cooling fans. Reduce load if continuously overheating.
- Error Codes on LCD: Refer to the specific error code in the full manual (if available) or contact customer support with the code.
- WiFi Module Not Connecting: Ensure the WiFi module is correctly installed and within range of your network. Check network settings.
User Tips:
- WiFi Module Tracking: If you purchased an inverter that includes a free WiFi module and have not received a tracking number for it (as it ships separately from China), please contact online customer service for assistance.
- On-Grid vs. Off-Grid: The ECO LV model supports both on-grid and off-grid functionality, while the HGX model is primarily designed for off-grid use. Confirm your model's capabilities for your specific setup.
10. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter and ensure the cooling vents are free from dust and debris. Use a soft, dry cloth.
- Connection Checks: Regularly inspect all electrical connections for tightness and signs of corrosion.
- Battery Health: Monitor your battery's health and charge levels. Follow battery manufacturer guidelines for maintenance.
- Firmware Updates: Check the manufacturer's website for any available firmware updates for your model.
11. Warranty and Support
For warranty information, technical support, or service requests, please contact your original point of purchase or the Sumry customer service department. Keep your purchase receipt and product serial number handy for faster service.
The product is certified with CE, indicating compliance with health, safety, and environmental protection standards.