SKE PH21-1.2K

Contents

SKE PH21 Series Hybrid Solar Inverter User Manual

Models: PH21-1.2K, PH21-3.6K, PH21-6.2K

1. Introduction

The SKE PH21 Series Hybrid Solar Inverter is a versatile power solution designed to integrate solar power, utility power, and battery power to provide continuous energy supply. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SKE PH21 Series inverter.

Key features include a wide PV input voltage range, selectable AC/solar input charging current, comprehensive protection mechanisms, and smart battery management. It is suitable for various applications, from personal computers to home appliances and industrial systems.

2. Key Features

  • Pure sine wave output for sensitive electronics.
  • Wide PV input voltage range (60-500VDC) for flexible solar panel configurations.
  • Selectable AC/Solar input charging current to optimize battery charging.
  • Overload and short circuit protection for enhanced safety.
  • Cold start function for reliable operation in various conditions.
  • Built-in anti-dust kit for harsh environments, ensuring longevity.
  • Capable of working with or without a battery.
  • Configurable with mains voltage or generator power as input sources.
  • Smart battery charger design for optimized battery performance and lifespan.
  • Dual communication ports for battery management system (BMS) and WiFi (optional).
  • WiFi monitoring available for iOS and Android devices (optional).
SKE Hybrid Solar Inverter PH21 Series Key Features
Figure 2.1: Key features of the SKE PH21 Series Hybrid Solar Inverter, including rated power, surge power, efficiency, and MPPT solar charger type.

3. Technical Specifications

Feature PH21-1.2K PH21-3.6K PH21-6.2K
Rated Power 1200VA/1200W 3600VA/3600W 6200VA/6200W
INPUT
Voltage 230 VAC
Selectable Voltage Range 170-280VAC (For Personal Computers); 90-280VAC (For Home Appliances)
Frequency Range 50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode) 230VAC±5%
Peak Power 2400VA 7200VA 12400VA
Efficiency (Peak) 93%
Transfer Time 10 ms (For Personal Computers); 20 ms (For Home Appliances)
Waveform Pure sine wave
BATTERY
Battery Voltage 12 VDC 24 VDC 48 VDC
Floating Charge Voltage 13.5 VDC 27 VDC 54 VDC
Overcharge Protection 14.6 VDC 29.2 VDC 58.4 VDC
SOLAR CHARGER & AC CHARGER
Solar Charger Type MPPT
Maximum PV Array Open Circuit Voltage 450 VDC 500 VDC
Maximum PV Array Power 2000 W 4000 W 6000 W
MPP Range Operating Voltage 60-400VDC 60-450 VDC
Maximum Solar Charge Current 60 A 80 A
Maximum AC Charge Current 60A 80A
Maximum Charge Current 60 A 80 A
ENVIRONMENT
Humidity 5% to 95% Relative Humidity (Non-condensing)
Operating Temperature 0℃ to 50℃
Storage Temperature -15℃ to 60℃
PHYSICAL
Dimension DxWxH (mm) 354x261x399 334x309x109 440x309x109
Net Weight (kg) 5.7 8.3 9.6
Communication Interface USB/RS232
Product Dimensions Comparison for PH21-1.2K, PH21-3.6K, and PH21-6.2K
Figure 3.1: Visual comparison of the PH21-1.2K, PH21-3.6K, and PH21-6.2K models.

4. Product Components and Appearance

Familiarize yourself with the various parts of your SKE PH21 Series Hybrid Solar Inverter:

Appearance Instructions with Labeled Components of SKE PH21 Inverter
Figure 4.1: Labeled diagram of the SKE PH21 Series Hybrid Solar Inverter components.
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons (ENTER, DOWN, UP, ESC)
  6. Power on/off switch
  7. AC input terminal
  8. AC output terminal
  9. PV input terminals (PV IN+ / PV IN-)
  10. Battery input terminals (BAT+ / BAT-)
  11. Circuit breaker
  12. RS485 for BMS communication port
  13. Antenna (for optional WiFi module)

5. Installation and System Connection

Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Please follow these guidelines carefully.

5.1 System Overview

The SKE PH21 Series Hybrid Solar Inverter integrates solar panels, a battery, and the utility grid to power various AC loads. It can also be configured to work with a generator.

Inverter System Connection Diagram
Figure 5.1: Diagram illustrating the typical connection of the inverter within a solar power system, including solar panels, grid, battery, and various appliances.

5.2 Connection Steps (General)

  1. Mounting: Securely mount the inverter in a well-ventilated area, away from direct sunlight and moisture. Ensure adequate clearance for airflow around the unit.
  2. Battery Connection: Connect the battery bank to the BAT+ and BAT- terminals. Ensure correct polarity. The inverter supports 12VDC, 24VDC, or 48VDC battery systems depending on the model.
  3. PV Input Connection: Connect the solar panels to the PV IN+ and PV IN- terminals. Verify that the PV array's open circuit voltage and power are within the inverter's specifications.
  4. AC Input Connection: Connect the utility grid (or generator) to the AC input terminal. The inverter can be configured to prioritize mains voltage or generator power.
  5. AC Output Connection: Connect your AC loads (appliances, lights, etc.) to the AC output terminal.
  6. Communication: If using a battery management system (BMS) or WiFi monitoring, connect the respective cables to the RS485 port or install the optional WiFi module.
  7. Grounding: Ensure the inverter is properly grounded to prevent electrical hazards.
  8. Power On: After all connections are secure and verified, switch on the circuit breaker, then the inverter's power on/off switch.

CAUTION: All electrical installations should be performed by qualified personnel in accordance with local electrical codes and regulations.

6. Operation

6.1 LCD Display and Indicators

The LCD display provides real-time information about the inverter's status, input/output voltages, charging current, and other parameters. The status, charging, and fault indicators provide quick visual cues about the inverter's operational state.

6.2 Function Buttons

Use the function buttons (ENTER, DOWN, UP, ESC) to navigate through the LCD menu, view different parameters, and configure settings such as:

  • Input source priority (Solar first, Utility first, SBU priority).
  • Output voltage and frequency.
  • Battery type and charging parameters.
  • AC/Solar charging current limits.

6.3 Monitoring

If the optional WiFi module is installed, you can monitor the inverter's performance and status remotely via a dedicated mobile application on iOS or Android devices.

Play video
Watch video online
Video 6.1: An overview of the SKE Hybrid Solar Inverter, highlighting its features and design.

7. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your SKE PH21 Series Hybrid Solar Inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps, but regular checks are still recommended.
  • Connection Checks: Annually inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
  • Battery Health: If using a battery, monitor its health and charge levels regularly. Follow the battery manufacturer's maintenance guidelines.
  • Environment: Ensure the installation environment remains within the specified operating temperature and humidity ranges.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your inverter.

Problem Possible Cause Solution
Inverter not turning on No battery connection, low battery voltage, or main power switch off. Check battery connections and voltage. Ensure the main power switch is ON.
No AC output Overload, short circuit, or inverter in fault mode. Reduce load. Check for short circuits in wiring. Refer to fault indicator for specific error codes.
Battery not charging No PV input, low PV voltage, AC input not present, or charging settings incorrect. Check solar panel connections and sunlight. Verify AC input. Adjust charging settings via LCD menu.
Fault indicator active Internal error, over-temperature, or specific system fault. Note the error code on the LCD (if any). Power cycle the inverter. Ensure proper ventilation. If persistent, contact support.

For more detailed troubleshooting, refer to the specific error codes displayed on the LCD and consult the full product manual (if available).

9. User Tips

  • Optimize PV Array: Ensure your solar panel array voltage and current are within the optimal operating range (MPP range) for maximum efficiency.
  • Battery Sizing: Properly size your battery bank to match your energy consumption and desired backup time.
  • Ventilation: Always ensure the inverter has adequate ventilation to prevent overheating, especially in warmer climates.
  • Load Management: Avoid consistently running the inverter at its maximum rated power to prolong its lifespan.
  • Firmware Updates: Check with the manufacturer for any available firmware updates to improve performance or add new features.

10. Practical Applications

The SKE PH21 Series Hybrid Solar Inverter is designed for a wide range of applications, providing reliable power in various settings:

Practical Application Examples for SKE PH21 Inverter
Figure 10.1: Examples of practical applications for the SKE PH21 Series Hybrid Solar Inverter, including CCTV, industrial control systems, offices, solar power systems, supermarkets, and ventilation systems.

11. Warranty and Support

For any questions, technical assistance, or warranty claims, please contact SKE customer service using the information below:

Customer Service Contact Information
Figure 11.1: SKE Customer Service Contact Information.
  • WhatsApp: +86 13191616332 (Annie Mi)
  • Tel: +86 131 9161 6332
  • Email: 2230584618@qq.com

Please have your product model and serial number ready when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.