1. Introduction
The SKE PH21 Series Hybrid Solar Inverter is a versatile power solution designed to integrate solar power, utility power, and battery power to provide continuous energy supply. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SKE PH21 Series inverter.
Key features include a wide PV input voltage range, selectable AC/solar input charging current, comprehensive protection mechanisms, and smart battery management. It is suitable for various applications, from personal computers to home appliances and industrial systems.
2. Key Features
- Pure sine wave output for sensitive electronics.
- Wide PV input voltage range (60-500VDC) for flexible solar panel configurations.
- Selectable AC/Solar input charging current to optimize battery charging.
- Overload and short circuit protection for enhanced safety.
- Cold start function for reliable operation in various conditions.
- Built-in anti-dust kit for harsh environments, ensuring longevity.
- Capable of working with or without a battery.
- Configurable with mains voltage or generator power as input sources.
- Smart battery charger design for optimized battery performance and lifespan.
- Dual communication ports for battery management system (BMS) and WiFi (optional).
- WiFi monitoring available for iOS and Android devices (optional).
3. Technical Specifications
| Feature | PH21-1.2K | PH21-3.6K | PH21-6.2K |
|---|---|---|---|
| Rated Power | 1200VA/1200W | 3600VA/3600W | 6200VA/6200W |
| INPUT | |||
| Voltage | 230 VAC | ||
| Selectable Voltage Range | 170-280VAC (For Personal Computers); 90-280VAC (For Home Appliances) | ||
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | ||
| OUTPUT | |||
| AC Voltage Regulation (Batt. Mode) | 230VAC±5% | ||
| Peak Power | 2400VA | 7200VA | 12400VA |
| Efficiency (Peak) | 93% | ||
| Transfer Time | 10 ms (For Personal Computers); 20 ms (For Home Appliances) | ||
| Waveform | Pure sine wave | ||
| BATTERY | |||
| Battery Voltage | 12 VDC | 24 VDC | 48 VDC |
| Floating Charge Voltage | 13.5 VDC | 27 VDC | 54 VDC |
| Overcharge Protection | 14.6 VDC | 29.2 VDC | 58.4 VDC |
| SOLAR CHARGER & AC CHARGER | |||
| Solar Charger Type | MPPT | ||
| Maximum PV Array Open Circuit Voltage | 450 VDC | 500 VDC | |
| Maximum PV Array Power | 2000 W | 4000 W | 6000 W |
| MPP Range Operating Voltage | 60-400VDC | 60-450 VDC | |
| Maximum Solar Charge Current | 60 A | 80 A | |
| Maximum AC Charge Current | 60A | 80A | |
| Maximum Charge Current | 60 A | 80 A | |
| ENVIRONMENT | |||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Operating Temperature | 0℃ to 50℃ | ||
| Storage Temperature | -15℃ to 60℃ | ||
| PHYSICAL | |||
| Dimension DxWxH (mm) | 354x261x399 | 334x309x109 | 440x309x109 |
| Net Weight (kg) | 5.7 | 8.3 | 9.6 |
| Communication Interface | USB/RS232 | ||
4. Product Components and Appearance
Familiarize yourself with the various parts of your SKE PH21 Series Hybrid Solar Inverter:
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons (ENTER, DOWN, UP, ESC)
- Power on/off switch
- AC input terminal
- AC output terminal
- PV input terminals (PV IN+ / PV IN-)
- Battery input terminals (BAT+ / BAT-)
- Circuit breaker
- RS485 for BMS communication port
- Antenna (for optional WiFi module)
5. Installation and System Connection
Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Please follow these guidelines carefully.
5.1 System Overview
The SKE PH21 Series Hybrid Solar Inverter integrates solar panels, a battery, and the utility grid to power various AC loads. It can also be configured to work with a generator.
5.2 Connection Steps (General)
- Mounting: Securely mount the inverter in a well-ventilated area, away from direct sunlight and moisture. Ensure adequate clearance for airflow around the unit.
- Battery Connection: Connect the battery bank to the BAT+ and BAT- terminals. Ensure correct polarity. The inverter supports 12VDC, 24VDC, or 48VDC battery systems depending on the model.
- PV Input Connection: Connect the solar panels to the PV IN+ and PV IN- terminals. Verify that the PV array's open circuit voltage and power are within the inverter's specifications.
- AC Input Connection: Connect the utility grid (or generator) to the AC input terminal. The inverter can be configured to prioritize mains voltage or generator power.
- AC Output Connection: Connect your AC loads (appliances, lights, etc.) to the AC output terminal.
- Communication: If using a battery management system (BMS) or WiFi monitoring, connect the respective cables to the RS485 port or install the optional WiFi module.
- Grounding: Ensure the inverter is properly grounded to prevent electrical hazards.
- Power On: After all connections are secure and verified, switch on the circuit breaker, then the inverter's power on/off switch.
CAUTION: All electrical installations should be performed by qualified personnel in accordance with local electrical codes and regulations.
6. Operation
6.1 LCD Display and Indicators
The LCD display provides real-time information about the inverter's status, input/output voltages, charging current, and other parameters. The status, charging, and fault indicators provide quick visual cues about the inverter's operational state.
6.2 Function Buttons
Use the function buttons (ENTER, DOWN, UP, ESC) to navigate through the LCD menu, view different parameters, and configure settings such as:
- Input source priority (Solar first, Utility first, SBU priority).
- Output voltage and frequency.
- Battery type and charging parameters.
- AC/Solar charging current limits.
6.3 Monitoring
If the optional WiFi module is installed, you can monitor the inverter's performance and status remotely via a dedicated mobile application on iOS or Android devices.
7. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your SKE PH21 Series Hybrid Solar Inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps, but regular checks are still recommended.
- Connection Checks: Annually inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
- Battery Health: If using a battery, monitor its health and charge levels regularly. Follow the battery manufacturer's maintenance guidelines.
- Environment: Ensure the installation environment remains within the specified operating temperature and humidity ranges.
8. Troubleshooting
This section provides solutions to common issues you might encounter with your inverter.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No battery connection, low battery voltage, or main power switch off. | Check battery connections and voltage. Ensure the main power switch is ON. |
| No AC output | Overload, short circuit, or inverter in fault mode. | Reduce load. Check for short circuits in wiring. Refer to fault indicator for specific error codes. |
| Battery not charging | No PV input, low PV voltage, AC input not present, or charging settings incorrect. | Check solar panel connections and sunlight. Verify AC input. Adjust charging settings via LCD menu. |
| Fault indicator active | Internal error, over-temperature, or specific system fault. | Note the error code on the LCD (if any). Power cycle the inverter. Ensure proper ventilation. If persistent, contact support. |
For more detailed troubleshooting, refer to the specific error codes displayed on the LCD and consult the full product manual (if available).
9. User Tips
- Optimize PV Array: Ensure your solar panel array voltage and current are within the optimal operating range (MPP range) for maximum efficiency.
- Battery Sizing: Properly size your battery bank to match your energy consumption and desired backup time.
- Ventilation: Always ensure the inverter has adequate ventilation to prevent overheating, especially in warmer climates.
- Load Management: Avoid consistently running the inverter at its maximum rated power to prolong its lifespan.
- Firmware Updates: Check with the manufacturer for any available firmware updates to improve performance or add new features.
10. Practical Applications
The SKE PH21 Series Hybrid Solar Inverter is designed for a wide range of applications, providing reliable power in various settings:
11. Warranty and Support
For any questions, technical assistance, or warranty claims, please contact SKE customer service using the information below:
- WhatsApp: +86 13191616332 (Annie Mi)
- Tel: +86 131 9161 6332
- Email: 2230584618@qq.com
Please have your product model and serial number ready when contacting support.