GVDA GD128

Contents

GVDA GD128 Digital Smart Multimeter

Instruction Manual

1. Introduction

The GVDA GD128 is a professional digital smart multimeter designed for measuring various electrical parameters. It is suitable for professional electricians, engineers, electronic enthusiasts, and general household use. This manual provides detailed instructions for safe and effective operation of your GD128 multimeter.

Key Features:

  • VA Colour Larger HD LCD Display
  • Maximum display: 9999 Counts
  • Auto range and Manual Range selection
  • Sampling Rate: Approximately 3 times per second
  • Over range display: "OL" indication
  • Low battery indication
  • Working environment: 0-40°C, relative humidity <80%
  • Input Jack LED Indication
  • Stable performance, high precision, high reliability, clear readings, and overload protection
  • Smart Function (Automatic identification for AC/DC Voltage, Resistance, and Continuity)
  • Auto Identification of current input
  • Relative Measurement mode
  • Max/Min/Avg. value recording
  • NCV (Non-Contact Voltage) / Live / Continuity test with sound and light alarm
  • Diode test with sound alarm
  • Bargraph display, Data hold, True RMS measurement
  • Fuse Burning Prompt
  • Auto power off function
  • Integrated Flashlight

2. Package Contents

Verify that all items listed below are included in your package:

  • 1x GVDA GD128 Digital Smart Multimeter
  • 1x Pair of Test Leads (pen cable)
  • 1x Cloth Bag
  • 1x K-type Thermocouple Probe
  • 1x User Manual (this document)
Detailed view of the GVDA GD128 Multimeter package contents, including the multimeter, test leads, cloth bag, and thermocouple probe.
Figure 2.1: Package Contents

3. Device Overview

Familiarize yourself with the different parts of your GVDA GD128 Multimeter:

Introduction diagram of the GVDA GD128 Multimeter with numbered parts: 1. NCV Sensor area, 2. Power key, 3. Flashlight key, 4. Warning indicator, 5. Flashlight, 6. Input jack indicator, 7. Jack other than current and NCV, 8. COM jack, 9. mA(<600mA) jack, 10. 10A jack, 11. Auto power off key, 12. Function key, 13. Display.
Figure 3.1: Multimeter Parts Diagram
  1. NCV Sensor area
  2. Power key
  3. Flashlight key
  4. Warning indicator
  5. Flashlight
  6. Input jack indicator
  7. Jack other than current and NCV
  8. COM jack
  9. mA(<600mA) jack
  10. 10A jack
  11. Auto power off key
  12. Function key
  13. Display

4. Setup

4.1 Battery Installation

The GVDA GD128 Multimeter requires 3x 1.5V AAA batteries (not included) for operation.

  1. Ensure the multimeter is powered off.
  2. Locate the battery compartment cover on the back of the device.
  3. Use a screwdriver to open the battery compartment.
  4. Insert three 1.5V AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Replace the battery compartment cover and secure it with the screw.
Battery compartment of the GVDA GD128 Multimeter, showing placement for 3 AAA batteries.
Figure 4.1: Battery Installation

5. Operating Modes

The GD128 offers various measurement functions. Use the 'AUTO FUNC' button to switch between automatic and manual ranging, and the 'RANGE' or 'SEL' buttons to select specific functions within a mode.

5.1 Smart Function (Auto Identification)

In Smart mode, the multimeter automatically identifies and measures AC/DC Voltage, Resistance, and Continuity, simplifying common tasks.

GVDA GD128 Multimeter performing smart AC/DC voltage, resistance, and continuity measurement in an electrical panel.
Figure 5.1: Smart Function in Use

5.2 NCV (Non-Contact Voltage) Measurement

Use the NCV function to detect AC voltage without direct contact. The device will beep and light up when close to a live power source.

GVDA GD128 Multimeter performing NCV (Non-Contact Voltage) measurement near a power outlet.
Figure 5.2: NCV Measurement

5.3 Temperature Measurement

Connect the K-type thermocouple probe to measure temperature. The multimeter supports measurements from -40°C to 1000°C (-40°F to 1832°F).

GVDA GD128 Multimeter performing temperature measurement with a K-type thermocouple probe in a glass of water.
Figure 5.3: Temperature Measurement

5.4 Other Functions

The multimeter supports a wide range of other functions, including:

  • AC/DC Voltage: Measure voltage in various circuits.
  • AC/DC Current: Measure current up to 10A.
  • Resistance Measurement: Determine the resistance of components.
  • Capacitance Measurement: Measure capacitance values.
  • Diode Test: Check the functionality of diodes.
  • Continuity Test: Verify circuit continuity with an audible beep.
  • Frequency Measurement: Measure the frequency of AC signals.
  • Duty Cycle: Measure the duty cycle of pulsed signals.
  • MAX/MIN/AVG: Record maximum, minimum, and average values during measurement.
  • Data Hold: Freeze the current reading on the display.
  • Flashlight: Use the built-in LED flashlight for illumination in dark areas.
Grid of images demonstrating various function tests: AC Voltage and Frequency, LIVE single pen fire line recognition, Diode test, Capacitance Measurement, Resistance Measurement, DC Voltage measurement, On/Off beep with indicator light, NCV Non-Contact Voltage Measurement.
Figure 5.4: Various Function Tests

6. Specifications

Function Range Accuracy
DC Voltage 99.99mV/999.9mV; 9.999V/99.9V/1000V ±(0.5%+3)
AC Voltage 99.9mV/999.9mV; 9.999V/99.9V/750V ±(0.8%+3)
DC Current 9.999mA/99.99mA/999.9mA ±(0.8%+3)
9.99A ±(1.2%+3)
AC Current 9.999mA/99.99mA/999.9mA ±(1.0%+3)
9.99A ±(1.5%+3)
Resistance 99.99/999.9ohm/9.999k/99.99k/999.9kohm ±(0.8%+3)
9.999M/99.99M Ohm ±(1.2%+3)
Capacitance 9.999/99.99/999.9nF/9.999/99.99/999.9uF ±(4.0%+3)
9.999mF/99.99mF ±(5.0%+5)
Frequency 99.99/999.9/9.999k/99.99k/999.9kHz/9.999mHz ±(1.0%+3)
Duty Cycle 0.1%-99.99% ±(1.0%+2)
Temperature °C/°F -40~1000°C; -40-1832°F ±2°C
Counts 9999 counts
Display VA Colour Display Screen
Product Weight Approx. 230g
Product Size 83x23x165mm
Safety Rating EN61010-1,-2-030 EN61010-2-033, EN61326-1 CAT III 1000V CAT IV 600V
Dimensions of the GVDA GD128 Multimeter, showing a length of 165.5mm, width of 83mm, and thickness of 22.3mm.
Figure 6.1: Multimeter Dimensions

7. Maintenance

7.1 General Care

  • Keep the multimeter clean and dry. Use a soft, damp cloth for cleaning; do not use abrasive cleaners or solvents.
  • Store the device in its protective cloth bag when not in use to prevent damage.
  • Avoid exposing the multimeter to extreme temperatures, high humidity, or direct sunlight.
  • Do not operate the multimeter if it appears damaged or if the test leads are compromised.
GVDA GD128 Multimeter with its protective soft cover, highlighting its durability.
Figure 7.1: Protective Soft Cover

7.2 Battery Replacement

When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Follow the battery installation steps in Section 4.1.

8. Troubleshooting

If you encounter issues with your multimeter, refer to the following common problems and solutions:

  • No display or faint display: Check battery installation and replace batteries if necessary.
  • "OL" (Overload) displayed: The measured value exceeds the selected range. Switch to a higher range or ensure the input is within the device's capabilities.
  • Inaccurate readings: Ensure test leads are properly connected, batteries are fresh, and the correct measurement function is selected. Clean the test lead tips if they appear dirty.
  • No continuity beep: Check if the continuity function is selected and if the circuit is indeed continuous.

9. User Tips

  • Always start with the highest range when measuring an unknown voltage or current to prevent damage to the multimeter.
  • Utilize the 'AUTO FUNC' mode for quick and convenient measurements of common parameters like voltage, resistance, and continuity.
  • The built-in flashlight is useful for working in dimly lit environments.
  • Keep the multimeter in its protective cloth bag to extend its lifespan and maintain accuracy.

10. Warranty and Support

The GVDA GD128 Digital Smart Multimeter comes with a 12-month warranty from the date of purchase. During the warranty period, if any quality problem arises, please contact the seller with photos or videos demonstrating the issue. The seller will advise on whether to send replacement parts, or if the instrument needs to be returned for repair or exchange. Please contact support before returning any product.

For customer service inquiries, you may contact the manufacturer at: 86-755-27597356.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.