1. Product Introduction
The SKE PH21 Series Hybrid Solar Inverter is an advanced power solution designed for residential and commercial solar power systems. It integrates a solar charge controller, inverter, and AC charger into one compact unit, providing a reliable power supply. This inverter is capable of working with or without a battery, offering flexibility for various energy storage and backup power needs. It features a high-precision sensing chip for stable measurement, robust stainless steel construction for durability, and a wide voltage input range for compatibility with different power sources. The PH21 series is compatible with PLCs, digital meters, and other control systems, making it a versatile choice for modern energy management.


2. Product Features
- Built-in MPPT Solar Charge Controller (150A) for efficient solar energy harvesting.
- Wide PV input voltage range (60-500Vdc) for flexible solar panel configurations.
- Selectable AC/Solar input charging current to optimize battery charging.
- Configurable with mains voltage or generator power, ensuring continuous operation.
- Capable of working with or without a battery, adapting to various system designs.
- Dual communication ports for battery management and WiFi connectivity (optional).
- WiFi available for iOS and Android for remote monitoring and control.
- High frequency design with over 94% efficiency.
- Comprehensive protection features: Overload, Over-temperature, Voltage, Short Circuit, and Overcurrent Protection.
- Built-in anti-dust kit for enhanced durability in harsh environments.
- Cold start function for reliable operation.
- Smart battery charger design for optimized battery performance.


3. Applications
The SKE PH21 Series Hybrid Solar Inverter is ideal for various applications, including:
- Residential solar power systems for home energy independence.
- Off-grid power solutions for remote cabins or areas without reliable grid access.
- Backup power systems for essential loads during grid outages.
- Commercial and industrial applications requiring stable and efficient power conversion.
- Powering a wide range of appliances, from personal computers and lighting to heavy-duty equipment like air conditioners and submersible pumps.

4. Technical Specifications
The following table details the technical specifications for the SKE PH21 series hybrid solar inverters:
| Parameter | PH21-3.2K | PH21-3.6K | PH21-6.2K | PH21-8.2K | PH21-10.2K |
|---|---|---|---|---|---|
| Rated battery voltage | 12VDC | 24VDC | 48VDC | 48VDC | 48VDC |
| Rated power | 3200W | 3600W | 6200W | 8200W | 10200W |
| Peak power | 6400W | 7200W | 12400W | 16400W | 20400W |
| Waveform | Pure Sine Wave | ||||
| Inverter output AC voltage (Battery mode) | (220Vac-240Vac)±5% 230Vac [Default] | ||||
| Inverter efficiency (Max) | 94% | ||||
| Transfer time | 10ms (UPS); 20ms (Home Appliances) | ||||
| No load power consumption | <30W@12VDC | <30W@24VDC | <40W@48VDC | <75W@48VDC | |
| AC Input Voltage | 230Vac | ||||
| Selectable voltage range | 170-280Vac (UPS); 90-280Vac (APL) | ||||
| Frequency range | 50Hz/60Hz (Auto sensing) | ||||
| Battery voltage | 12VDC | 24VDC | 48VDC | 48VDC | 48VDC |
| Floating charging voltage | 13.5VDC | 27VDC | 54VDC | 54VDC | 54VDC |
| Overcharge protection voltage | 14.6VDC | 29.2VDC | 58.4VDC | 58.4VDC | 58.4VDC |
| Solar charger type | MPPT | ||||
| MPPT maximum PV array power | 2000W | 4000W | 6200W | 8200W | 10500W |
| MPPT output voltage range | 60-450V | 60-450V | 60-450V | 60-450V | 60-450V |
| Maximum PV array open circuit voltage | 450V | 500V | 500V | 500V | 500V |
| Maximum solar charge current | 60A | 80A | 80A | 150A | 150A |
| Maximum AC charge current | 60A | 80A | 80A | 120A | 120A |
| Maximum charge current | 60A | 80A | 80A | 150A | 150A |
| Machine size (W*D*H) (mm) | 261*399*354 | 309*109*334 | 309*109*440 | 390*138*500 | 390*138*500 |
| Package size (W*D*H) (mm) | 472*545*180 | 452*395*180 | 550*395*190 | 620*492*263 | 620*492*263 |
| Net weight (kg) | 5.7 | 8.3 | 9.6 | 18 | 18 |
| Gross weight (kg) | 6.7 | 9.3 | 10.6 | 19 | 19 |
| Humidity | 5% to 95% Relative humidity (Non-condensing) | ||||
| Operating temperature | 0°C ~ 55°C | ||||
| Storage temperature | -15°C ~ 60°C | ||||

5. Package List
Upon receiving your SKE PH21 Series Hybrid Solar Inverter, please verify that all items listed below are included and in good condition:
- 1 x SKE PH21 Series Hybrid Solar Inverter
- 1 x User Manual
- 1 x Communication Cable (USB/RS232)
- 1 x WiFi Module (Optional, if purchased)
- Mounting Hardware (Screws, wall anchors)
6. Safety Notes
Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- This product is not explosion-proof. Do not use in flammable or explosive environments.
- Always disconnect all power sources (AC grid, solar panels, battery) before performing any wiring or maintenance.
- Ensure correct polarity when connecting batteries and solar panels. Reverse wiring may damage the inverter.
- Keep the inverter away from strong electromagnetic interference sources.
- Do not disassemble or modify the product yourself. Unauthorized modifications will void the warranty and pose safety risks.
- Ensure proper grounding of the inverter.
- Install the inverter in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
- Follow all local and national electrical codes and industrial safety standards during installation and use.
7. Installation Instructions
Proper installation is crucial for the safe and efficient operation of your SKE Hybrid Solar Inverter. It is recommended that installation be performed by a qualified electrician or solar professional.
7.1. Mounting the Inverter
- Choose a stable, vertical surface for mounting, free from strong vibration or impact.
- Ensure adequate clearance around the inverter for proper ventilation (at least 20 cm on all sides).
- Avoid mounting in direct sunlight or areas exposed to extreme temperatures or humidity.
- Use appropriate mounting hardware to securely fasten the inverter to the wall.
7.2. Component Overview
Familiarize yourself with the inverter's external components and connection points:

- LCD display
- Function buttons
- Antenna (for WiFi, if applicable)
- RS-232/RS485 communication port
- Power on/off switch
- AC input (Ground/L/N)
- AC output (Main out for critical load, supports battery backup discharge)
- AC output (Bypass from AC input for non-critical loads, excess solar energy fed back)
- PV1+ input
- PV1- input
- PV2+ input
- PV2- input
- Battery + Terminal
- Battery - Terminal
8. Wiring Instructions
All wiring must comply with local and national electrical codes. Ensure all power sources are disconnected before making any connections.
8.1. System Connection Diagram
The following diagram illustrates a typical system connection for the SKE Hybrid Solar Inverter:

8.2. Connection Steps
- Battery Connection: Connect the battery bank to the Battery + and Battery - terminals (13, 14) on the inverter. Ensure correct polarity.
- Solar Panel (PV) Connection: Connect your solar panel array to the PV1+/PV1- (9, 10) and PV2+/PV2- (11, 12) inputs. Observe correct polarity and ensure the PV voltage is within the inverter's specified range (60-500Vdc).
- AC Input (Grid/Generator) Connection: Connect the AC grid or generator supply to the AC Input (6) terminals (Ground/L/N).
- AC Output (Load) Connection: Connect your critical loads to the Main Out (7) terminals and non-critical loads to the Home Out (8) terminals.
- Communication Ports: Connect USB/RS232 cables (4) for monitoring or the optional WiFi module for remote access.
- Grounding: Ensure the inverter is properly grounded according to local electrical codes.
9. Operating Instructions
After all connections are securely made and verified, you can proceed with powering on and operating the inverter.
9.1. Powering On
- Ensure all external circuit breakers for the battery, solar panels, and AC input/output are in the OFF position.
- Turn on the battery breaker first.
- Turn on the solar panel (PV) breaker.
- Turn on the AC input (grid/generator) breaker.
- Finally, turn on the inverter's Power On/Off switch (5). The LCD display (1) will light up.
9.2. LCD Display and Function Buttons
The LCD display provides real-time system status, and the function buttons (2) allow you to navigate menus and configure settings. Refer to the video for a visual demonstration of display operation.
9.3. Basic Operation Modes
The inverter typically operates in several modes, which can be configured via the LCD display:
- Utility Priority: Grid power is the primary source, solar/battery acts as backup.
- Solar Priority: Solar power is the primary source, followed by battery, then grid.
- Battery Priority: Battery power is the primary source, followed by solar, then grid.
Consult the detailed user manual (PDF) for specific menu navigation and parameter settings.
10. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust accumulation. Use a dry, soft cloth. Do not use liquid cleaners.
- Connections Check: Annually inspect all electrical connections (battery, PV, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
- Environment: Ensure the installation environment remains within specified temperature and humidity ranges. Keep the area around the inverter clear for proper airflow.
- Battery Health: If using batteries, monitor their health and performance according to the battery manufacturer's guidelines.
11. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No battery power; loose connections; inverter switch off | Check battery voltage; verify all connections; ensure inverter switch is ON |
| No AC output | Overload; short circuit; inverter fault | Reduce load; check for short circuits; check inverter display for error codes |
| Solar panels not charging battery | Low PV voltage; incorrect PV connection; MPPT fault | Check PV voltage and connections; ensure sufficient sunlight; consult manual for MPPT settings |
| Error code on display | Specific system fault | Refer to the user manual (PDF) for the meaning of the specific error code and recommended actions. |
12. User Tips
- Optimize PV Array: For maximum efficiency, ensure your solar panel array voltage is within the optimal operating range for the MPPT controller (e.g., 60-450Vdc).
- Battery Compatibility: While the inverter works with various battery types, ensure your battery's voltage and capacity are compatible with the inverter model. For optimal performance and longevity, consider LiFePO4 batteries.
- Remote Monitoring: If you have the optional WiFi module, utilize the iOS/Android app for remote monitoring of your system's performance and status. This can help in early detection of issues.
- Load Management: Distribute your loads between 'Main Out' (critical) and 'Home Out' (non-critical) outputs as per your energy priorities, especially during grid outages.
13. Warranty and Support
SKE provides comprehensive support for its products.
13.1. Warranty
This product comes with a 2-year warranty from the date of delivery. During the warranty period, SKE will provide free parts for quality-related issues. The warranty does not cover improper operation or man-made damage.
13.2. Technical Support
Professional technical support is available for wiring, application, and troubleshooting. For any issues or inquiries, please contact our customer service team:

WhatsApp: +86 13191616332
Tel: +86 131 9161 6332
Email: 2230584618@qq.com
For a detailed user manual, please refer to the PDF document referenced here: User manual (PDF)
14. Frequently Asked Questions (FAQ)
Q1: What kind of certifications does SKE have?
A: SKE products hold various certifications including ISO9000, ISO14001, ISO45001, CE, ROHS, FCC, and PSE. Our products are designed to pass different laboratory testing requirements across various countries.