1. Introduction
The Suoer PV100 Series Hybrid Solar Pumping Inverter is an advanced solution designed for efficient water pumping in agricultural irrigation and other applications. This inverter utilizes self-adaptive power point tracking technology to achieve up to 99% efficiency, ensuring optimal performance from your solar panels. It features automatic regulation of pump flow and self-adaptation to the drive used in the installation, offering a plug-and-play system design. The inverter is battery-free for most applications and engineered for effortless maintenance.
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Suoer PV100 Series Solar Pumping Inverter.
2. Product Overview
The Suoer PV100 Series Solar Pumping Inverter is designed with user-friendly controls and robust construction. Below is an overview of its main components and their functions.

2.1. Control Panel and Indicators
The inverter features an intuitive control panel for easy operation and monitoring:
- Programming Key (01): Used to enter programming mode and adjust settings.
- Quick Key (02): Provides quick access to frequently used functions.
- Run Key (03): Initiates the pump operation.
- Entry Key (04): Confirms selections and enters values.
- Right-Shift Key (05): Moves the cursor or shifts digits during parameter setting.
- Stop/Reset Key (06): Stops the pump operation or resets error states.
- Up Key (07): Navigates up through menus or increases values.
- Down Key (08): Navigates down through menus or decreases values.
- Indicator Light (09): Displays the operational status of the inverter (e.g., Run, Fault).
- Wiring Hole (10): Provides access for electrical connections.
- Cooling Fan (11): Ensures proper heat dissipation for optimal performance.
- Name Plate (12): Contains product identification and electrical ratings.
2.2. Typical Applications
This solar pumping inverter is suitable for various applications, including:
- Agricultural irrigation
- Domestic water supply
- Desert control
- Pasture animal husbandry
- Island water supply
- Landscape fountains
3. Specifications
The following table details the technical specifications for the Suoer PV100 Series Solar Pumping Inverter, specifically for the PV100-015G-4T model, and other related models.

| Attribute | Value |
|---|---|
| Model Number | PV100-015G-4T |
| Product Name | 15KW Solar Pumping Inverter |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | CE, TUV/ISO |
| Place of Origin | Guangdong, China |
| Output Current | 32A |
| Output Frequency | 50HZ/60HZ |
| Output Type | Triple, TRIPLE |
| Type | DC/AC pump Inverters |
| Phase | Three-Phase 380V |
| GPRS Function | Optional |
| Communication | RS485 |
| Max Input Voltage (PV) | 800V DC |
| Start-up Voltage (PV) | 250VDC |
| Lowest Working Voltage (PV) | 250VDC |
| Recommended DC Input Voltage Range (PV) | 300-750VDC |
| Recommended MPPT Voltage (PV) | 550VDC |
| Input Voltage (AC/Generator) | 380V (-15%)+10% VAC Three Phase |
| Rated Input Current (AC/Generator) | 32A |
| Rated Output Power (KW) | 15KW |
| Rated Output Voltage | 380V (-15%)+10% VAC Three Phase |
| Rated Output Current | 32A |
| Protection Level | IP20 |
| Ambient Temperature Range | -20°C ~ 45°C |
| Cooling Method | Fan Cooling |
4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your solar pumping inverter. It is recommended that installation be performed by a qualified electrician or solar technician.
4.1. Unpacking and Inspection
Upon receiving your inverter, carefully unpack it and inspect for any signs of damage during transit. The package should include:
- Suoer Solar Pumping Inverter unit
- User Manual (this document)
- Certificate of Quality
4.2. Mounting Location
Choose a mounting location that is:
- Well-ventilated to allow for proper cooling (Ambient Temperature Range: -20°C ~ 45°C).
- Protected from direct sunlight, rain, and excessive dust.
- Accessible for maintenance and operation.
- Securely mounted on a stable surface.
4.3. Wiring Diagram
Follow the wiring diagram carefully to ensure correct and safe connections. Incorrect wiring can lead to damage to the inverter, pump, or solar panels, and may pose a safety hazard.

Key Connections:
- Solar PV Input: Connect the DC output from your solar panel array to the designated PV input terminals on the inverter. Ensure correct polarity (positive to positive, negative to negative). The maximum input voltage is 800V DC.
- AC Grid/Generator Input (Optional): If using a hybrid system, connect the three-phase 380V AC power supply from the grid or a generator to the AC input terminals.
- Motor Output: Connect the three-phase motor of your water pump to the inverter's motor output terminals.
- Grounding: Ensure the inverter is properly grounded according to local electrical codes.
WARNING: Always disconnect all power sources before making or breaking any electrical connections.
5. Operating Instructions
The Suoer PV100 Series Inverter is designed for ease of use. Follow these steps for basic operation:
5.1. Initial Power-Up
- After ensuring all wiring is correct and secure, switch on the DC power from the solar panels.
- If using AC input, switch on the AC power supply.
- Observe the indicator lights (09) on the control panel. The inverter should perform a self-check.
5.2. Starting the Pump
- Press the Run Key (03) on the control panel.
- The inverter will automatically detect the maximum power point of the solar panels (MPPT technology) and adjust the pump's speed to optimize water flow.
- The indicator light should show a "Run" status.
5.3. Stopping the Pump
- Press the Stop/Reset Key (06) on the control panel.
- The pump will gradually slow down and stop.
5.4. Parameter Adjustment (Advanced)
For advanced settings and parameter adjustments, refer to the detailed programming guide (not included in this general manual, typically found in a full technical manual). Use the Programming Key (01), Up Key (07), Down Key (08), Right-Shift Key (05), and Entry Key (04) to navigate and modify parameters.
6. Maintenance
The Suoer PV100 Series Inverter is designed for effortless maintenance. Regular checks will ensure long-term reliability and optimal performance.
6.1. Routine Checks
- Visual Inspection: Periodically inspect the inverter for any visible damage, loose connections, or signs of overheating.
- Cleanliness: Keep the inverter clean and free from dust and debris. Pay particular attention to the cooling fan (11) and ventilation openings to ensure unrestricted airflow. Use a soft, dry cloth for cleaning.
- Connections: Ensure all electrical connections (PV input, AC input, motor output, grounding) are tight and secure.
6.2. Environmental Considerations
- Ensure the ambient temperature remains within the specified range (-20°C to 45°C).
- Protect the inverter from moisture and corrosive environments.
WARNING: Always disconnect power before performing any maintenance or cleaning.
7. Troubleshooting
The Suoer PV100 Series Inverter incorporates several protection features to ensure safe operation. If the inverter is not functioning as expected, consult the following table for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not powering on | No DC input from PV panels; Incorrect wiring; Low PV voltage; Blown fuse. | Check PV panel connections and voltage; Verify wiring; Ensure sufficient sunlight; Check fuses. |
| Pump not running | Inverter in fault state; Motor connection issue; Insufficient PV power; Overload. | Check indicator lights for fault codes; Press Stop/Reset key; Verify motor wiring; Check PV input power; Reduce load if possible. |
| Low water flow/poor performance | Insufficient solar irradiance; PV panels dirty; Pump issues; Inverter not optimized. | Clean PV panels; Check for shading; Inspect pump for blockages; Ensure inverter is operating in MPPT mode. |
| Overheat protection triggered | Poor ventilation; Clogged cooling fan; High ambient temperature; Overload. | Ensure adequate clearance around inverter; Clean cooling fan and vents; Relocate inverter if ambient temperature is consistently high; Reduce load. |
| Undervoltage protection triggered | Low PV input voltage; Insufficient solar panels. | Verify PV array voltage meets minimum requirements; Add more PV panels if necessary. |
| Short Circuit/Open Circuit protection triggered | Wiring fault in motor or PV array. | Inspect all wiring for shorts or open circuits. Consult a qualified technician. |
If the problem persists after attempting these solutions, please contact customer support or a qualified technician.
8. User Tips
While no specific user reviews or Q&A were provided, here are some general tips for maximizing the performance and lifespan of your solar pumping inverter:
- Optimize Panel Orientation: Ensure your solar panels are optimally angled and oriented towards the sun for maximum energy harvest throughout the day and seasons.
- Regular Cleaning: Keep solar panels clean from dust, dirt, and bird droppings to maintain efficiency.
- Monitor Performance: Periodically check the inverter's display for operational status and output to ensure it's working efficiently.
- Prevent Shading: Avoid any shading on your solar panels, even partial shading can significantly reduce output.
- Water Level Management: If your pump draws from a well or reservoir, ensure adequate water levels to prevent dry running, which can damage the pump.
9. Warranty and Support
9.1. Product Warranty
The Suoer PV100 Series Hybrid Solar Pumping Inverter comes with a one-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal operating conditions. Please retain your proof of purchase for warranty claims.
9.2. Technical Support
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your seller or authorized Suoer service center. Provide your product model number (PV100-015G-4T) and a detailed description of the issue when seeking support.