1. Introduction
This manual provides detailed instructions for the HTOOL HT008 and SL22 RF Signal Generators. These devices are designed for generating stable and precise RF signals across a wide frequency range, suitable for various testing and development applications.
1.1 Product Overview
The HTOOL signal generators come in two main variants:
- HT008: Features the MAX2871 chip, GD32F303 main control, and a 0.96-inch OLED screen. It supports USB to serial communication via a built-in CH340G chip.
- SL22: Utilizes the LMX2820 chip, GD32F427 main control, and a larger 2.8-inch LCD screen. It also supports USB virtual serial port communication.

1.2 Package Contents
Please check the contents of your package against the list below. If any items are missing or damaged, contact your vendor.
HT008 Package:
- 1x MAX2871 23.5-6000MHz Signal Source unit (HT008)
- 1x Type-USB data connection cable

SL22 Package:
- 1x SL22 Signal Generator
- 1x Type-C Data Cable
- 1x Stylus
- 2x SMA male to male extension cables
- 1x SMA female to female adapter
- 1x N female to SMA male adapter
- 1x BNC female to SMA male adapter
- 1x SMA female to F female adapter
- 1x SMA male to BNC male adapter

2. Specifications
2.1 HT008 Specifications
| Feature | Description |
|---|---|
| Main Chip | MAX2871 |
| Main Control | GD32F303 |
| Display | 0.96-inch OLED (90*160 resolution) |
| Frequency Range | 23.5MHz - 6000MHz (6GHz) |
| Frequency Resolution | 78Hz (for frequencies ≤ 4MHz) |
| Phase Noise | -111dBc@3GHz: 100KHz |
| Output Channels | Dual Channel |
| Channel 1 Output Power | -1dBm, -1dBm, 2dBm, 5dBm (selectable) |
| Channel 2 Output Power | 16-level attenuation, -15dBm to -25dBm |
| Operating Modes | Point Frequency, Sweep |
| Communication Interface | Built-in USB serial port (CH340G) |
| Power Supply | USB power, 5V 1A battery power |

2.2 SL22 Specifications
| Feature | Description |
|---|---|
| Product Model | SL22 |
| Function | Signal Source, Spectrum Analyzer |
| Main Chip | LMX2820 |
| Main Control | GD32F427 |
| Display | 2.8-inch LCD (240*320 resolution) |
| Frequency Range | CH1, CH2: 45MHz - 22GHz |
| Power Range | P0~P7: -16dBm~7dBm (8 levels) |
| Frequency Accuracy | 1KHz |
| Sweep Width | 45MHz - 22GHz |
| Sweep Step | Min 1KHz, Max 22555MHz |
| Sweep Time | 1ms - 10s |
| Output Signal | Sine Wave |
| Output Interface | SMA (external thread, internal hole) |
| Power Interface | TYPE-C |
| Product Dimensions | 132*74*22mm |
| Product Weight | 200g |
| Power Supply | 5V, 2A or higher adapter power supply |
| Special Feature | Memory function for user settings |



3. Setup
3.1 Power Connection
Both HT008 and SL22 models are powered via a Type-C USB port. Connect the provided USB cable to the device and a compatible 5V, 2A or higher power adapter (not included) or a USB port on a computer.
- HT008: Can also be powered by a 5V 1A battery power supply.
- SL22: Requires a 5V, 2A or higher adapter for optimal performance.

3.2 Driver Installation (for Serial Control)
For serial control functionality, a USB driver may be required. Connect the device to your computer and install the necessary drivers if prompted or if the device is not recognized. The HT008 uses a CH340G chip, and the SL22 uses a virtual serial port.
3.3 RF Output Connection
The devices feature SMA output interfaces (external thread, internal hole). Use appropriate SMA cables and adapters (some included with SL22) to connect the signal generator to your testing equipment.

4. Operation
The signal generators offer Point Frequency and Sweep modes. Navigation is typically done using the physical buttons (left, right, up, down, OK) or the touchscreen/stylus for the SL22 model.
4.1 General Navigation
Use the directional buttons to move the cursor on the screen and select menu options. The 'OK' button (or equivalent) confirms selections or enters sub-menus.

4.2 Point Frequency Mode
In this mode, you can set a single, stable output frequency.
- Navigate to the "Point Frequency" mode on the device.
- Use the left/right buttons to move the cursor to the frequency setting.
- Use the up/down buttons to adjust the desired frequency value.
- For HT008, select CH1 or CH2. For SL22, click "Set Frequency" and input the value.
- Confirm the setting (e.g., press OK or "On" for SL22) to activate the output.
- Adjust output power as needed through the "Power" setting in the interface.
4.3 Sweep Mode
Sweep mode allows the generator to sweep through a range of frequencies.
- Navigate to the "Sweep" mode.
- Select either "Single Sweep" or "Cyclic Sweep" (SL22).
- Use the left/right buttons to move the cursor to adjust the "Start Frequency" and "End Frequency".
- Set the "Sweep Step" and "Single Step Time" (or "Sweep Time").
- Important: Ensure the Start Frequency is less than or equal to the End Frequency. Also, verify that the sweep time and step size are set to valid values to prevent malfunction. If these parameters are not set correctly, the sweep function will not operate. You may need to re-open the sweep function after correcting settings.
- Adjust output power as needed through the "Power" setting in the interface.
4.4 Dual Channel Output (HT008)
The HT008 offers two independent output channels:
- Channel 1: Provides selectable output power levels of -1dBm, -1dBm, 2dBm, or 5dBm.
- Channel 2: Offers 16-level attenuation, ranging from -15dBm to -25dBm.
4.5 Memory Function (SL22)
The SL22 model includes a memory function that allows it to recall user-set point frequencies or sweep settings. This means the device can start working immediately with your last configuration upon power-on.
4.6 Serial Control
Both models support USB serial port control for advanced operations and secondary development. Specific control commands are available for integration with external software or custom applications. Refer to the manufacturer's documentation or development resources for detailed command protocols.
5. Maintenance
5.1 General Care
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Do not drop or subject the device to strong impacts.
- Ensure proper ventilation. The SL22 model has ventilation holes on the side; do not obstruct them.

5.2 Storage
When not in use for extended periods, store the signal generator in a cool, dry place, preferably in its original packaging or a protective case.
6. Troubleshooting
6.1 No Power / Device Not Turning On
- Ensure the USB cable is securely connected to both the device and the power source.
- Verify that the power adapter meets the specified requirements (5V, 2A or higher for SL22; 5V 1A for HT008).
- Try a different USB cable or power adapter.
- For SL22, ensure the ON/OFF switch is in the 'ON' position.
6.2 No Signal Output
- Check that the output frequency and power settings are correctly configured in the device's menu.
- Ensure the SMA cables and connectors are properly attached and not damaged.
- Verify that the device is in the correct operating mode (Point Frequency or Sweep).
- If in Sweep mode, confirm that the start frequency, end frequency, and sweep time/step are set to valid values. If the start frequency is greater than the end frequency, or sweep time/step is invalid, the sweep will not operate.
6.3 Computer Not Recognizing Device (for Serial Control)
- Ensure the correct USB serial port drivers are installed on your computer.
- Try connecting to a different USB port on your computer.
- Restart your computer and the signal generator.
7. User Tips
- For precise frequency adjustments, utilize the fine-tuning options available in the menu.
- When performing sweeps, always double-check your start and end frequencies, as well as the step size and time, to avoid unexpected behavior.
- Consider using the serial control interface for automated testing or integration into larger systems, as it offers more granular control.
- Keep the firmware updated to ensure optimal performance and access to new features. Check the manufacturer's website for updates.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the vendor or manufacturer directly. Keep your purchase receipt as proof of purchase.