SUSWE SU900-7R5G3

Contents

SUSWE SU900-7R5G3 3 Phase Frequency Converter Inverter User Manual

Model: SU900-7R5G3 | Brand: SUSWE

1. Product Introduction

The SUSWE SU900-7R5G3 is a high-performance 3-phase frequency converter inverter designed to efficiently convert 50Hz to 60Hz power for various industrial applications. This Variable Frequency Drive (VFD) is rated at 7.5kW (10HP) and operates on a 380V power supply. It offers precise control over motor speed and torque, enhancing energy efficiency and operational flexibility for machinery. Its robust design ensures stable and reliable performance in demanding industrial environments.

Front view of the SUSWE SU-900 frequency converter

Figure 1.1: Front view of the SUSWE SU-900 Frequency Converter.

2. Key Features

  • Frequency Conversion: Converts 50Hz to 60Hz, suitable for adapting machinery to different power standards.
  • Variable Speed Control: Provides precise control over motor speed, optimizing process efficiency and reducing energy consumption.
  • V/F Vector Control: Advanced control mode for stable and efficient motor operation.
  • Robust Design: Built for industrial environments with an IP40 protection level.
  • Detachable Control Panel: Allows for flexible installation and remote operation, enhancing user convenience.
  • Comprehensive Protection: Includes short circuit protection and other safety features to ensure reliable operation.

3. Technical Specifications

3.1 General Parameters

ParameterValue
Product NameFrequency Inverter VFD
Brand NameSUSWE
Model NumberSU900-7R5G3
TypeAC-DC-AC
Rated Power7.5KW (10HP)
Nominal Voltage380V
Power Phase NumberThree Phase
Control ModeV/F vector control
IP LevelIP40
SizeDepending on the model
CustomizedYes
Battery IncludedNo
CertificationCE
OriginMainland China (Jiangsu)

3.2 Model Naming Rules

Diagram explaining SU800/900 series naming rules for voltage and power grades.

Figure 3.1: SU800/900 Series Naming Rules. This diagram illustrates how model numbers are structured based on voltage and power grades.

3.3 Frequency Converter Series Index

Table showing SU800/900 series index for single phase 220V power supply, 50Hz/60Hz, with power capacity, input/output current, and adapted motor kW/HP.

Figure 3.2: SU800/900 Series Index (Single Phase 220V). This table provides detailed specifications for single-phase models.

Table showing SU800/900 series index for three phase 380V power supply, 50Hz/60Hz, with power capacity, input/output current, and adapted motor kW/HP.

Figure 3.3: SU800/900 Series Index (Three Phase 380V). This table provides detailed specifications for three-phase models, including the SU900-7R5G3.

4. Installation and Wiring

4.1 Installation Instructions

  1. Install the frequency converter in a stable, well-ventilated position, free from strong vibration or impact.
  2. Ensure adequate clearance around the unit for proper heat dissipation.
  3. Mount the unit securely using appropriate fasteners.

4.2 Wiring Connections

Proper wiring is crucial for safe and effective operation. Always ensure power is disconnected before making any connections.

Terminal wiring diagram for frequency converter control circuit, showing triphase input 380V, braking resistance, various digital and analog inputs/outputs, RS485 communication, and DC24V power supply.

Figure 4.1: Terminal Wiring Diagram for Frequency Converter Control Circuit. This diagram shows connections for 380V triphase input, braking resistance, digital/analog I/O, RS485, and DC24V power.

Wiring diagram for a 12V 40A 500W power supply, showing input (110V~240V), output to electric machinery, and warm tips for wiring (AC, L, DC, N, ground, +V, -V).

Figure 4.2: Example Power Supply Wiring Diagram. This diagram illustrates connections for a power supply, including input (110V-240V), output to electric machinery, and grounding.

General Wiring Principles (3-wire system for control signals):

  • VCC: Connect to the positive terminal of the control power supply (e.g., DC 5V / 12V / 24V).
  • GND: Connect to the negative terminal of the control power supply / Ground.
  • OUT: Connect to the signal input of the receiving device.
Image showing various views of the inverter: Front, Front side, Rear Side.

Figure 4.3: Inverter Product Description - Front, Front Side, and Rear Side Views for understanding terminal locations.

5. Operation

5.1 Control Panel Overview

Close-up of the control panel with labels for knob, display screen, run key, stop key, confirm key, programming key, incremental key, shift key, decrement key. Also shows operation indicator, command indicator, forward and reverse, tuning/fault indicator.

Figure 5.1: Control Panel Layout and Indicators. This image details the functions of each button and display element.

The control panel provides an interface for monitoring and controlling the VFD. Key elements include:

  • Display Screen: Shows real-time frequency (Hz), current (A), and voltage (V).
  • Knob: Used for adjusting frequency or other parameters.
  • RUN Key: Initiates motor operation.
  • STOP/RESET Key: Halts motor operation and can reset fault conditions.
  • ENTER Key: Confirms parameter settings.
  • PRG Key: Enters programming mode to configure VFD parameters.
  • Arrow Keys (Up/Down): Used for navigating menus and adjusting values.
  • MFK Key: Multi-function key, typically used for shifting digits during parameter entry or accessing specific functions.
  • Indicators: LEDs for operation (RUN), command (F/R for Forward/Reverse), and tuning/fault (TU/TC) provide status feedback.

5.2 Detachable Operation Panel

The VFD features a detachable operation panel, allowing for remote control and flexible mounting. To remove the panel, gently press inward on the clips and pull it away from the main unit. It can then be connected via an extension cable (e.g., Ethernet cable) for remote access.

Image showing the detachable operation panel being removed by pressing inward.

Figure 5.2: Removing the Detachable Operation Panel. Press inward on the clips to detach.

Image showing the detachable panel connected via an Ethernet cable for remote operation.

Figure 5.3: Detachable Panel for Remote Operation. The panel can be connected remotely via a cable.

5.3 Operational Demonstration

The following video demonstrates key operational aspects of the inverter, including panel testing, controlling positive and negative motor rotation, and the functionality of the removable panel.

Video 5.1: Demonstration of Inverter Functions (Panel Test, Positive/Negative Operation, Removable Panel).

6. Maintenance

To ensure the longevity and optimal performance of your SUSWE frequency converter, regular maintenance is recommended:

  • Cleaning: Keep the unit clean and free from dust, metal particles, and other debris. Use a soft, dry cloth for cleaning.
  • Ventilation: Ensure proper airflow around the VFD to prevent overheating. Regularly check that cooling fans (if present) are clean and operating correctly.
  • Connection Checks: Periodically inspect all wiring connections for tightness, corrosion, or signs of wear. Loose connections can lead to poor performance or damage.
  • Environmental Conditions: Avoid exposing the unit to excessive moisture, corrosive gases, or extreme temperatures outside its specified operating range.
  • Firmware Updates: Consult SUSWE support for information on any available firmware updates that may improve performance or add features.

7. Safety Notes and Basic Troubleshooting

7.1 Safety Notes

  1. This product is NOT explosion-proof. Do not use it in flammable or explosive environments.
  2. Always disconnect all power sources (input and output) before performing any wiring, installation, or maintenance to prevent electric shock or damage to the unit.
  3. Ensure correct wiring polarity. Reverse wiring may cause severe damage to the VFD.
  4. Keep the unit away from strong electromagnetic interference sources to prevent operational errors.
  5. Do not disassemble or modify the product yourself. Unauthorized modifications will void the warranty and can lead to dangerous conditions.
  6. Always follow local and industrial safety standards and regulations during installation, operation, and maintenance.

7.2 Basic Troubleshooting - Short Circuit Protection

The SUSWE SU900-7R5G3 VFD is equipped with built-in short circuit protection. In the event of an output short circuit, the VFD will automatically trip and display an error code to protect itself and the connected motor. To resolve a short circuit fault:

  1. Immediately disconnect power to the VFD.
  2. Inspect the motor and output wiring (U, V, W terminals) for any signs of short circuits, damaged insulation, or loose connections.
  3. Correct any identified wiring issues or motor faults.
  4. Reconnect power and clear the fault from the VFD's control panel (usually by pressing the STOP/RESET key).
  5. If the fault persists, consult the detailed troubleshooting section in the full user manual (PDF) or contact technical support.

Video 7.1: Short Circuit Function Protection Test (part of the inverter demonstration video).

8. User Tips

  • Parameter Configuration: Take time to properly configure the VFD parameters (e.g., motor rated current, frequency limits, acceleration/deceleration times) to match your specific motor and application requirements for optimal performance and motor protection.
  • Remote Control: Leverage the detachable control panel for convenience. If the VFD is installed in a hard-to-reach location, use an extension cable to mount the panel in an accessible area for easier monitoring and control.
  • Cooling: Ensure the VFD's cooling fins are not obstructed. Proper airflow is critical for preventing overheating, especially during continuous high-load operation.
  • Grounding: Always ensure the VFD and the motor are properly grounded to prevent electrical hazards and reduce electromagnetic interference.

9. Package Contents

Upon receiving your SUSWE SU900-7R5G3 Frequency Converter Inverter, please verify that the following items are included:

  • 1 x SUSWE SU900-7R5G3 Frequency Converter Inverter
  • 1 x User Manual (this document)
  • (Optional) 1 x Seal Gasket (may be included with certain models or accessories)

10. Warranty and Support

Your SUSWE frequency converter inverter is backed by comprehensive support:

  • Warranty Period: 3 months to 1 year, depending on the specific product and regional policies.
  • After-Sales Service: Free service is provided for non-human quality defects.
  • Technical Support: Professional technical assistance is available for wiring, application, and troubleshooting.

For further assistance or inquiries, please use the contact information below:

Contact information including WhatsApp, Phone, and Email for customer service.

Figure 10.1: Customer Service Contact Information.

A more detailed user manual in PDF format is available for download: View Full User Manual (PDF)

11. Frequently Asked Questions (FAQ)

Q: What is the warranty period for this product?
A: The warranty period ranges from 3 months to 1 year. Please refer to the 'Warranty and Support' section for specific details.
Q: How can I ensure the quality of the product?
A: Our products undergo strict quality control processes, including pre-production sampling and final inspection before shipment, to ensure high reliability and performance.
Q: Can I disassemble or modify the inverter myself?
A: No, unauthorized disassembly or modification will void the product warranty and may lead to safety hazards. For any service or repair, please contact qualified technical personnel or our customer support.
Q: What should I do if the VFD displays a fault code?
A: First, disconnect power. Then, consult the detailed troubleshooting section in the full user manual (PDF) for specific fault code explanations and corrective actions. If the issue persists, contact our technical support team.