1. Introduction
The KKMOON FY868 Cable Tester is a versatile tool designed for telecommunication engineers, wiring engineers, and network maintenance professionals. It is capable of accurately testing and tracing RJ45 network cables and RJ11 telephone wires. This device helps in detecting various cable faults such as open circuits, short circuits, wrong circuits, and reversed circuits, ensuring efficient network and telephone line maintenance.

Figure 1: FY868 Cable Tester complete kit
2. Package Contents
Please check the package carefully to ensure all items are present:
- 1 x Emitter (Battery not included)
- 1 x Receiver (Battery not included)
- 1 x Crocodile Clip Test Line
- 1 x User Manual
- 1 x RJ45 Cable (random color)
- 1 x Cloth Pouch
- 1 x Earphone

Figure 2: Included accessories
3. Specifications
| Feature | Detail |
|---|---|
| Work Temperature | 0~40℃, max 80% relative humidity (non-condensing) |
| Storage Temperature | -10~50℃, max 80% relative humidity (non-condensing, no battery) |
| Elevation | <2000 meters |
| Type of Anti-explosion | IP 40 |
| Distance of Sending Signal | >3000 meters |
| Emitter Battery | 3 x 1.5V/AAA (not included) |
| Receiver Battery | 1 x 6F22/9V (not included) |
| Item Color | Green |
| RJ45 Cable Length | 16.8cm / 6.6in |
| Weight | Approx. 360g / 12.7oz (total package weight) |
4. Setup
4.1 Battery Installation
- Locate the battery compartments on the back of both the Emitter and the Receiver units.
- Open the battery covers.
- Insert 3 x 1.5V AAA batteries into the Emitter, observing correct polarity.
- Insert 1 x 9V 6F22 battery into the Receiver, observing correct polarity.
- Close the battery covers securely.

Figure 3: Battery compartments on Emitter and Receiver
4.2 Connecting Cables
Depending on the test you wish to perform, connect the appropriate cable to the Emitter unit:
- For RJ45 Network Cables: Use the provided RJ45 cable to connect the network cable to the RJ45 port on the Emitter.
- For RJ11 Telephone Wires: Connect the telephone wire to the RJ11 port on the Emitter.
- For other cables/wires: Use the crocodile clip test line to connect to the desired wires.
5. Operating Instructions
5.1 General Operation
- Turn on the Emitter using the ON/OFF switch.
- Turn on the Receiver using its ON/OFF switch.
- Adjust the volume knob on the Receiver to a comfortable listening level.

Figure 4: Emitter controls
5.2 Cable Sorting (Network/Telephone Cables)
This function detects physical connections in a cable, identifying open circuits, short circuits, wrong circuits, and reversed circuits.
- Connect one end of the RJ45 or RJ11 cable to the corresponding port on the Emitter.
- Connect the other end of the cable to the corresponding port on the Receiver.
- Set the Emitter to 'TEST' mode (if applicable, or ensure it's emitting a signal).
- Observe the LED indicators on both the Emitter and Receiver. The sequence of lit LEDs will indicate the cable's wiring status.
- A normal cable will show LEDs lighting up in sequence (1-8 for RJ45, 1-2 for RJ11). Deviations indicate faults:
- Open Circuit: An LED fails to light up.
- Short Circuit: Two or more LEDs light up simultaneously or out of sequence.
- Wrong/Reversed Circuit: LEDs light up in an incorrect sequence.

Figure 5: Receiver ports and LED indicators
5.3 Wire Tracking
This function allows you to trace a specific wire within a bundle or locate its endpoint.
- Connect the Emitter to the cable you wish to trace (using RJ45, RJ11, or crocodile clips).
- Set the Emitter to 'SCAN' or 'TONE' mode to generate an audible signal.
- Take the Receiver unit and move its probe along the suspected path of the cable.
- Listen for the tone emitted by the Receiver. The tone will be loudest when the probe is directly over the target cable.
- The Receiver also has LED indicators that may light up to visually confirm the signal strength.
- Use the earphones for clearer detection in noisy environments.

Figure 6: Emitter and Receiver in operation
5.4 Line Level and Polarity Detection
The Emitter can be used to detect the line level or positive and negative electrode of a circuit.
- Connect the crocodile clip test line to the Emitter.
- Attach the clips to the wires you want to test.
- Observe the indicators on the Emitter to determine the line level or polarity.
6. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the device in its cloth pouch in a cool, dry place when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears or if the device's performance degrades. Always use fresh batteries of the specified type.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Dead or incorrectly installed batteries | Check battery polarity; replace with fresh batteries. |
| No signal detected during wire tracking | Emitter not in SCAN/TONE mode; Receiver volume too low; Cable not properly connected | Ensure Emitter is in correct mode; increase Receiver volume; verify cable connections. |
| Inaccurate cable test results | Poor cable connection; damaged test cable; interference | Ensure secure connections; try a different test cable; minimize electromagnetic interference. |
| Weak or distorted tone | Low battery; excessive distance; interference | Replace batteries; reduce distance between Emitter and Receiver; use earphones for clarity. |
8. User Tips
- For best results in noisy environments, always use the included earphones during wire tracking.
- When testing long cables, ensure both the Emitter and Receiver have fresh batteries for optimal signal strength.
- Always disconnect the device from cables and power off after use to conserve battery life.
- Keep the probe of the Receiver clean and free from debris to ensure accurate detection.
9. Warranty and Support
This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.