Lilytech ZL-7816A

Contents

ZL-7816A Temperature and Humidity Controller

User Manual

1. Introduction

The Lilytech ZL-7816A is a versatile microcomputer-controlled device designed for precise management of both temperature and humidity. Featuring a user-friendly interface with digital displays and intuitive button operation, it ensures stable and reliable performance. This controller is ideal for applications requiring independent control over environmental temperature and humidity, such as incubators, greenhouses, and storage facilities.

Front view of the ZL-7816A controller and its connected temperature and humidity sensor.
Figure 1: ZL-7816A Temperature and Humidity Controller with Sensor

2. Product Features

  • Microcomputer control for stable and reliable operation.
  • Intuitive button interface for easy setup and adjustment.
  • Dual digital display for simultaneous temperature and humidity readings.
  • High-resolution display: 0.1°C for temperature and 0.1%RH for humidity.
  • Automatic restart function retains settings after power interruptions.
  • Independent control outputs for both temperature and humidity.
  • Long-range sensor capability (up to 50 meters) for flexible placement and accurate data collection.

3. Specifications

ParameterValue
ModelZL-7816A
Power Supply12V AC/DC
Temperature Measuring Range0.0°C to 80.0°C
Humidity Measuring Range0.0%RH to 99.9%RH
Temperature Precision±1% (under 20~60°C)
Humidity Precision±3%RH (under 20~60°C)
Load Current250VAC/7A
Power Consumption< 2W
Working Environment Temperature0°C to 45°C
Working Environment Humidity5% to 95% RH (without dewing)
Dimensions (L*W*H)118mm * 75mm * 32mm
Weight0.26 kg
MaterialPCB and plastics

4. Setup and Installation

4.1 Wiring Instructions

Proper wiring is crucial for the safe and correct operation of the ZL-7816A controller. Refer to the wiring diagram below for connections. Ensure all connections are secure and insulated.

Wiring diagram for the ZL-7816A controller, showing connections for 12V AC/DC power, temperature/humidity sensor, and 220V AC loads for temperature and humidity control.
Figure 2: ZL-7816A Wiring Diagram
  • Power Input (12V AC/DC): Connect your 12V AC or DC power supply to the designated terminals at the top of the controller.
  • Sensor Connection (T/H Sensor): Connect the provided temperature and humidity sensor to the "Sensor" terminals. The sensor cable can be extended up to 50 meters if needed.
  • Load Connections (TempLoad & HumLoad):
    • The controller provides two independent relay outputs: one for temperature control (TempLoad) and one for humidity control (HumLoad).
    • Each output has Normally Open (N.O.), Common (COM), and Normally Closed (N.C.) terminals.
    • Connect your temperature-controlling device (e.g., heater, cooler) to the TempLoad COM and N.O. terminals.
    • Connect your humidity-controlling device (e.g., humidifier, dehumidifier) to the HumLoad COM and N.O. terminals.
    • The diagram indicates that the loads can be powered by an external AC220V source, which is switched by the controller's relays. Ensure the load's voltage and current ratings do not exceed 250VAC/7A.

4.2 Sensor Placement

Place the temperature and humidity sensor in the environment you wish to monitor and control. Ensure it is not directly exposed to heat sources, moisture, or airflow that could lead to inaccurate readings.

5. Operation

The ZL-7816A controller features a simple three-button interface: 'S' (Set), 'Up Arrow', and 'Down Arrow'.

  • Power On: Once wired correctly, apply 12V AC/DC power. The controller will power on and display current temperature and humidity.
  • Setting Parameters:
    • Press the 'S' button to enter the setting mode.
    • Use the 'Up Arrow' and 'Down Arrow' buttons to navigate through parameters and adjust values.
    • Press 'S' again to confirm a setting and move to the next parameter, or to exit the setting mode.
    • Specific parameters for temperature set point, humidity set point, hysteresis, and other advanced functions will be detailed in the full product manual (if available).
  • Automatic Operation: After setting your desired temperature and humidity values, the controller will automatically activate the respective loads (heater/cooler, humidifier/dehumidifier) to maintain the set conditions.
  • Auto Restart: The controller is equipped with an auto-restart function, meaning all your configured parameters are saved and will be restored automatically after a power outage.

6. User Tips

  • Sensor Calibration: For critical applications, periodically verify the sensor's accuracy against a known good thermometer/hygrometer and recalibrate if necessary (refer to advanced settings in the full manual).
  • Load Capacity: Always ensure that the connected heating/cooling and humidifying/dehumidifying devices do not exceed the controller's maximum load current of 7A at 250VAC. Overloading can damage the unit.
  • Environmental Stability: For best control, minimize external factors that cause rapid fluctuations in temperature and humidity in the controlled environment.

7. Troubleshooting

  • Controller Not Powering On:
    • Check the 12V AC/DC power supply connection.
    • Verify the power source is active and providing the correct voltage.
  • Incorrect Temperature/Humidity Readings:
    • Ensure the sensor is correctly plugged into the controller.
    • Check the sensor cable for any damage.
    • Verify the sensor's placement is appropriate and not affected by direct heat/moisture.
  • Loads Not Activating/Deactivating:
    • Confirm the wiring of the loads (heater/humidifier) to the COM and N.O. terminals as per the wiring diagram.
    • Check the set points for temperature and humidity to ensure they are configured to trigger the loads under current conditions.
    • Verify the loads themselves are functional and receiving power.
    • Ensure the load current does not exceed 7A.
  • Controller Displaying Error:
    • If an error code appears, consult the full product manual for specific meanings.
    • Often, errors relate to sensor disconnections or malfunctions. Recheck sensor connections.

8. Maintenance

  • Cleaning: Keep the controller and sensor clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Environmental Conditions: Operate the device within the specified working environment temperature (0~45°C) and humidity (5~95% RH, non-condensing) to ensure longevity.
  • Cable Integrity: Periodically inspect all wiring and sensor cables for signs of wear or damage. Replace damaged cables immediately.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Ensure you have your product model number (ZL-7816A) and purchase details available when seeking support.