1. Introduction
The ZL-7901A is an advanced PID multifunctional automatic intelligent incubator controller designed for precise control of temperature and humidity in hatching environments. It features a large display, rich functionality, and flexible settings, making it suitable for high-level incubators. This manual provides detailed instructions for installation, operation, parameter configuration, and troubleshooting to ensure optimal performance of your incubator system.
2. Features
The ZL-7901A controller offers a comprehensive set of features for efficient incubator management:
- Temperature control: Relays up/down limit control, SSR PID control.
- Humidity or dehumidify control.
- Timer air exhaust control.
- Timer egg turning control.
- Illumination control.
- Alarm output.
- Auto restart function.
- Temperature/humidity over limit warning and protection.
- Temperature/humidity sensor fault warning and protection.
3. Specifications
Below are the technical specifications for the ZL-7901A controller:
| Parameter | Value |
|---|---|
| Power Supply | 100-240VAC, 50 or 60Hz |
| Main Heater Relay Output | 7.5A / 1.0A (Resistive) |
| Aux Heater Relay Output | 7.5A / 1.0A (Resistive) |
| Humidity Control Relay Output | 7.5A / 1.0A (Resistive) |
| Lamp Control Relay Output | 7.5A / 1.0A (Resistive) |
| Air Exhaust Control Relay Output | 3A |
| Egg Turning Relay Output | 1A |
| Alarm Output Relay | 1A |
| SSR Driver Output | 20mA/10VDC MAX |
| Temperature Sensor Input | NTC temperature sensor, 5K/3470 |
| Humidity Sensor Input | ZL-SHr04J or ZL-SHr04P |
| Setting Range Humidity | 0-99% RH (ZL-SHr04J is for 0-80%RH, ZL-SHr04P is for 0-99%RH) |
| Accuracy Temperature | ±0.1°C |
| Accuracy Humidity | ±3%RH (ZL-SHr04J), ±2%RH (ZL-SHr04P) |
| Working Environment | -20~45°C, 10~90% RH without dew |
Note: If 7.5A rated current is for tungsten lamp, do not exceed 1.0A. If drive is for 5V (for external voltage to DC12VDC), it is in fact an AC/DC, with huge surging when power supplied, the service lifetime is not guaranteed.
4. Setup & Installation
Proper installation is crucial for the safe and effective operation of the ZL-7901A controller. Please follow the wiring diagram carefully.
4.1 Wiring Diagram
Wiring Instructions:
- Power Input (L, N): Connect 100-240Vac input to terminals L and N.
- Main Heater (R1): Connect the main heater to terminals 1 and 2.
- Auxiliary Heater (R2): Connect the auxiliary heater to terminals 3 and 4.
- Humidity Control (R3): Connect the humidity control device to terminals 5 and 6.
- Illumination (R4): Connect the lamp to terminals 7 and 8.
- Ventilation (R5): Connect the ventilation fan to terminals 9 and 10.
- Egg Turning Motor (R6, R7): Connect the egg turning motor to terminals 11 and 12 (Left-turning) and 13 and 14 (Right-turning).
- Alarm 1 & 2 (R8, R9): Connect alarm devices to terminals 15 and 16 (Alarm 1) and 17 and 18 (Alarm 2).
- Temperature Sensor: Connect the temperature sensor to the designated terminals.
- Humidity Sensor: Connect the humidity sensor to the designated terminals.
- Limit Switches (SQ1, SQ2): Connect limit switches for the egg turning motor.
- External Heater (SSR): Connect an external heater via an SSR (Solid State Relay) to the SSR output terminals.
Attention: Correct electrical wiring must be manipulated by certified electricians. Wrong wiring may damage the device and system seriously. Avoid installation in an environment with corrosive gases or strong electro-magnetic field. The device is possible abnormal in such condition.
4.2 Sensor Options
The ZL-7901A supports different humidity sensor options:
- ZL-SHr04J: Range 0-80%RH, Accuracy ±3%RH.
- ZL-SHr04P: Range 0-99%RH, Accuracy ±2%RH.
Ensure the correct sensor is connected and configured according to your specific needs.
5. Operation
This section details the basic operation and key functions of the ZL-7901A controller.
5.1 Key Functions
| Key | Function | Remark |
|---|---|---|
| Power | Keep depressed for 3 seconds to turn on/offline | |
| Set | Short press to switch between humidity set and temperature set; Long press to set other parameters (see Parameter Table below) | |
| Up Arrow (∧) | Increase the set value. Keep depressed for fast set. | |
| Down Arrow (∨) | Decrease the set value. Keep depressed for fast set. | |
| Enter | Confirmation | |
| Reset | Short press to cancel and return. | |
| Lamp | Long press to clear incubating accumulated days counter. | |
| Fn | Turn the lamp off/on | Combination key |
5.2 Display Icons
| Icon | Function | On | Off | Blinking |
|---|---|---|---|---|
| Humidity/Dehumidity state | Humidity/Dehumidity state | Energized | De-energized | |
| Main heater | Main heater | Energized | De-energized | |
| Auxiliary heater | Auxiliary heater | Energized | De-energized | |
| Air exhaust | Air exhaust | Energized | De-energized | |
| Egg turning motor, turn right | Egg turning motor, turn right | Energized | De-energized | |
| Egg turning motor, turn left | Egg turning motor, turn left | Energized | De-energized | |
| Warning | Warning | – | – | Warning |
| E01 | Temperature sensor fault | Warning | No warning | |
| E02 | Humidity sensor fault | Warning | No warning | |
| tHI | Temperature higher than up limit | Warning | No warning | |
| tLO | Temperature lower than down limit | Warning | No warning | |
| hHI | Humidity higher than up limit | Warning | No warning | |
| hLO | Humidity lower than down limit | Warning | No warning | |
| UnL | Restore to default parameters | Restoring to default parameters |
5.3 Key Operation
Fast Set Temperature (T11), Fast Set Humidity (H20):
- Press Set to switch between temperature and humidity setting. Press ∧ and ∨ to set the value.
- Press Enter to save the setting.
- Press Reset or without key operation for 30 seconds, exit the mode, and the set value is not saved.
Parameters Setting:
- Keep Set and ∨ depressed simultaneously for 3 seconds. LCD shows "Psd 000".
- Press ∧ and ∨ to enter password "default 000". Press Enter to confirm.
- The password is correct, enter into parameter setting mode. Press Exit.
- Press Set to select parameter code. Press ∧ and ∨ to set the value. Press Enter to save the setting.
- Press Reset or without key operation for 30 seconds, exit the mode, and the set value is not saved.
5.4 Fahrenheit/Celsius Display
Keep Fn and ∨ depressed simultaneously for 3 seconds to switch between Fahrenheit / Celsius display.
5.5 Incubation Day Counter
When controlling, the incubation day counter will keep counting. If the counter value reaches U18, controller keeps controlling as normal, and the counter value will be flashing. If the counter value reaches U18, stop counting. Keeping Lamp depressed for 3 seconds will reset the accumulated days of egg turning and incubation day counter.
5.6 Auto Restart Function
When the controller is offline, stop, and then comes back, the controller will run under the same settings before the power supply stops.
6. Parameter Settings
The ZL-7901A controller allows for detailed configuration of various parameters to suit different incubation needs. Refer to the tables below for a complete list of parameters and their functions.
6.1 Parameter Table (Temperature, Humidity, Egg Turning)
For detailed descriptions of each parameter (T10-T32, H10-H25, U10-U14, U20-U93), their ranges, units, indications, and default values, please refer to the images above or the full manual PDF.
6.2 PID Control Appendix
The controller supports PID auto-tuning for optimal temperature control. This function (T10=2) allows the controller to automatically find suitable PID parameters (Kp/Ti/Td). If PV is not able to reach SP within reasonable time, increase heater power rate. If PV overshoot or fall below SP, auto tuning is not able to get the PID parameters correctly.
For more advanced PID tuning and hysteresis control details, consult the appendix in the full manual.
7. Maintenance
To ensure the longevity and accurate performance of your ZL-7901A controller, follow these general maintenance guidelines:
- Keep the controller clean and free from dust and debris.
- Ensure proper ventilation around the unit to prevent overheating.
- Regularly check all wiring connections for tightness and signs of wear.
- Avoid exposing the controller to extreme temperatures, humidity, or corrosive environments.
- If the device is to be stored for an extended period, disconnect it from power and store it in a dry, cool place.
For any issues, refer to the troubleshooting section or contact support.
8. Troubleshooting
This section provides guidance for common issues and warning messages displayed by the ZL-7901A controller.
8.1 Warning Control Instruction
| No. | Code | Remark | Real time detection | Delay | Duration | Reset | Action |
|---|---|---|---|---|---|---|---|
| 1 | E01 | Temperature sensor fault | Yes | 0s | 0s | Auto | Alarming, temperature output off, the other control not affected |
| 2 | E02 | Humidity sensor fault | Yes | 0s | 0s | Auto | Alarming, humidity output off, the other control not affected |
| 3 | tHI | Over high temperature warning point | Yes | 0s | 0s | Auto | Alarming |
| 4 | tLO | Lower than low temperature warning point | Yes | 0s | 0s | Auto | Alarming |
| 5 | hHI | Over high humidity warning point | Yes | 0s | 0s | Auto | Alarming |
| 6 | hLO | Lower than low humidity warning point | Yes | 0s | 0s | Auto | Alarming |
| 7 | tCE | Touched IC fault | Yes | 0s | 0s | Auto | Alarming |
When there is error of sensors, high/low limit temperature or humidity warning, there will be buzzing warning. Any key press can stop the warning.
9. User Tips
- Temperature and Humidity Control: The ZL-7901A controller is designed to control both humidity and temperature, making it a versatile solution for various incubation needs.
- Wiring Safety: Always ensure that wiring is performed by a certified electrician to prevent damage to the device or system.
- Environment: Avoid installing the controller in areas with corrosive gases or strong electromagnetic fields to ensure stable operation.
10. Warranty & Support
This product has been strictly tested before shipping. The company warranty is one year. The responsibility is limited to the sale of this product itself. Damage caused by improper usage is not covered by the warranty.
For further assistance or technical support, please refer to the official Lilytech website or contact your vendor.
The full manual PDF can be downloaded from: www.suzhoulily.com/pdf/ZL-7901A_en_V2.6d.pdf