1. Introduction
The VOTOL EM180GTS SV200 is a sine wave type brushless DC controller designed for electric scooters and motorcycles. It features flux-weakening capabilities and is generally compatible with QS Motors. For new brand motors, some parameters may require self-testing and adjustment.
This manual provides detailed instructions for wiring, software connection, parameter configuration, and troubleshooting to ensure optimal performance and safe operation of your controller.
2. Package Contents
Each set of the VOTOL EM180GTS SV200 controller typically includes the following components:
Combo 1 (CAN BUS Version)
- 1 x EM180GTS/SV200 Sine Wave Controller with CAN BUS
- 1 x USB Programmable Cable
- 1 set x Plug-in (matching controller harness plug)
Combo 2 (One-LIN Version)
- 1 x EM180GTS/SV200 Sine Wave Controller with One-LIN
- 1 x USB Programmable Cable
- 1 set x Plug-in (matching controller harness plug)


3. Specifications
The VOTOL EM180GTS SV200 controller offers robust performance and features for electric vehicle applications.
| Feature | Specification |
|---|---|
| Brand Name | VOTOL (FARDRIVER) |
| Model | EM180GTS SV200 |
| Origin | Mainland China |
| Rated Voltage | 72V |
| Rated DC Current | 160A |
| Peak Phase Current | 490A |
| Boost DC Current | 250A |
| Rated Power | 3-5KW |
| Max. Efficiency | ≥93% |
| Flux Weakening | 200% |
| Waterproof Grade | IP67 |
| Net Weight | 1.2KG |
| Dimensions (L x W x H) | 186mm x 107mm x 60mm (approx.) |



4. Setup and Installation
4.1 Wiring Instructions
Proper wiring is crucial for the safe and correct operation of the controller. Refer to the diagrams and descriptions below for connecting the main functions and various components.


4.1.1 E-lock Connector
Connect the grey/purple E-lock wire to the ignition key. This controls the power to the controller.

4.1.2 Throttle Connector
Connect the throttle connector to the throttle, display, and brake system.
- Throttle 5V+ (Pink): Connects with throttle.
- Throttle - (Black): Connects with throttle.
- Throttle Signal (Green): Connects with throttle.
- Display Signal (White): Connects with display.
- Brake Signal (Purple): Connects with 12V brake.

4.1.3 Gears Connector
Connect the gears connector to the gears switch. Ensure the negative wire is properly connected.
- Gear 3 (Black/white)
- Negative - (Black)
- Gear 1 (Green/white)
- Gear Sport (Yellow/white)
- Gear Park (Brown/white)

4.1.4 Back & Kick Stand Connector
Connect the back switch and kick stand switch.
- Back (Grey/white): Connect to GND. Press the button and apply throttle for reversing rotation.
- Kick Stand (Grey/black): Connect to GND.

4.1.5 Restore Connector
Connect the restore button.
- Restore (Brown): If throttle and brake errors occur, double-press and then long-press for 2 seconds to activate the restore function.

4.1.6 Debugging Connector
Connect the debugging connector for PC USB cable and Bluetooth connection.
- 5V (Pink)
- Negative Pole (Black)
- Debugging RXD (Blue)
- Debugging TXD (Orange)
Important: Do not plug or unplug the debugging cable when the controller is powered on.

4.1.7 Hall Connector
Connect the Hall sensor wires as per the diagram.

4.1.8 Anti-theft Connector
Connect the anti-theft system wires.

4.2 Software Connection Manual
The controller can be connected to a PC for debugging and parameter configuration using a USB debugging cable.

4.2.1 Software Installation
When connecting the controller to the PC with the USB debugging cable, the driver should install automatically. If not, follow these steps:
- Decompress the file “USB-to-serial-win10-20150814” and then “YH-340 USB”.
- Choose and decompress the correct file based on your PC system (WIN7/WIN8/WIN10).
- Open Device Manager, navigate to “COM and LPT”, right-click the port with an exclamation mark, and select “Update the driver software”.
- Browse your computer for driver software and select the appropriate driver (e.g., 3.3.10.140 (2009-11-19) version).
- After successful installation, the port should appear without an exclamation mark. If not, reconnect the USB debugging cable.



4.2.2 Connecting Debugging Cable
Select the correct USB debugging cable (CAN or One-LIN version) and connect it to the PC and controller.
- For CAN Version: Use the specific CAN debugging cable.
- For One-LIN Version: Use the specific One-LIN debugging cable.


Once connected, open the PC controller software. Choose the correct baud rate (9600 for LIN, 115200 for CAN) and click “connect”. Ensure the controller is powered on. All parameters will then be displayed in the software.


If the controller cannot be connected, enter the advanced interface by typing “~” and pressing “shift”. In the advanced interface, choose the correct CAN baud rate and ID based on the controller model. Observe the values; when they rise, click page 1 to connect the controller.

5. Operating Parameters
The controller software allows for detailed configuration of various operating parameters. This section describes the settings available on different pages of the software interface.

5.1 Parameter Page 1
This page contains basic settings for voltage, current, and throttle response.
5.1.1 Voltage Settings
Configure overvoltage, undervoltage, and soft undervoltage parameters. These settings are crucial for battery protection.
- Battery Voltage (V): Select the controller's working voltage range.
- Overvoltage (V): Protection against excessive voltage.
- Undervoltage (V): Protection against low voltage.
- Soft Undervoltage (V): Reduces power and speed to protect the battery when voltage drops.
- Undervoltage Variation: Defines the voltage recovery threshold after an undervoltage fault.

5.1.2 Current Settings
Adjust regenerative and phase current limits.
- Regenerative (A): Set according to the maximum reverse charge current the battery can handle. Set to 0 if the battery does not support reverse charging.
- Phase Current: Set according to the maximum phase current value provided by the technical department. High values can lead to overheating.

5.1.3 Throttle Voltage Settings
Configure the throttle's voltage range and protection levels.
- Throttle Voltage Set: Define the actual lowest and highest voltage of your throttle.
- Low Protect: Prevents throttle errors if the signal voltage is too low during power-on.
- Start Voltage: Minimum voltage for the motor to start running.
- End Voltage: Maximum voltage for full output.
- High Protect Value: Stops the motor if throttle voltage exceeds this value.

5.1.4 Start Torque Settings
Adjust the motor's starting torque and delay.
- Start Torque: Usually set to 0.
- Combinative Torque: Controls the starting delay (0-350). Higher values mean more obvious delay.
These settings are particularly suitable for mid-drive motors with gearboxes to manage gear backlash.

5.1.5 Rate of Rise and Decline
Control the acceleration and deceleration characteristics.
- Rate of Rise: (10-255) Higher values result in faster acceleration.
- Rate of Decline: (10-200) Higher values result in more obvious speed drop and reduced throttle inertia.

5.2 Parameter Page 2
This page includes settings for flux-weakening, speed limits, and multi-speed modes.
5.2.1 Current/Flux-Weakening Settings
Adjust the maximum current and flux-weakening parameters.
- Max Current (A): Should be set under engineer guidance.
- Flux-Weakening: Broadens the speed range of permanent magnet synchronous motors. Higher values increase motor speed.
- KI Setting: Adjusts motor high-speed jitter. Increase to reduce jitter, decrease if no jitter.
- Automatic Logout Enablers:
- Logout Time (S): For S mode, automatically reduces speed and current to protect the battery.
- Recovery Time (S): Gap time for the second S mode function to prevent prolonged S mode operation.

5.2.2 Constant Speed/HHC (Hill Hold Control)
Enable or disable constant speed and hill hold functions.
- HHC Enable: Enables or disables the slope stop function.
- Constant Speed: Keeps motor speed constant within the maximum power range.
- Max. Limited RPM: Set equal to the motor landing speed.

5.2.3 Three-Speed Settings
Configure the current limits and default gear for three-speed modes.
- Low (%), Mid (%), Hige (%): Set current ratios for each speed mode.
- Start Phase Current: Maximum phase current limit for the first acceleration section.
- KP: Adjusts motor sound and resonance during starting.
- Three Speed Default Gear: Select the power-on default gear.
- Soft Start: Unchecked for hard start. Higher grade means more power at start.

5.3 Parameter Page 3
This page covers motor-specific settings, speedometer communication, and braking functions.
5.3.1 Motor Settings
Configure parameters specific to your motor type.
- Pole Pairs: Set according to your motor's pole pairs. Incorrect values affect motor speed.
- Exchange Hall Wire Color (Yellow-Blue): Decides motor rotation direction.
- Exchange Phase Wire Color (Blue-Green): Decides motor rotation direction.
- Hall Shift Angle: Set according to motor specifications (e.g., -60 for hub motors).
- Motor Type: Select 'surface-mount' for hub motors or 'V-type' for mid-drive motors.

5.3.2 Speedometer and Cruise Control
Configure speedometer communication and cruise control functions.
- Out-put (One-Lin / Hall Speedometer): Select communication method.
- Cruise: Enable or disable cruise function.
- Moving Vehicle Booster: Function for 2-wheelers, adjusts speed ratio and torque.
- Double-Voltage Automatic Identification Setting: Single voltage as default.

5.3.3 Braking and Secure Boot
Adjust reverse speed limits and electric braking.
- Reversing the Speed Limit (%): Sets the maximum speed in reverse.
- EBS Ratio (%): Sets electric brake regeneration power. Adjust for comfort when releasing handlebars and braking.
- Low Brake: Enables low brake signal.
- Secure Boot: Special soft function, off by default.

5.4 Advanced Page Settings
The advanced page provides additional diagnostic and configuration options.

5.4.1 Remote Control Interface
This interface allows for remote control and local control switching, as well as analog input monitoring.
- Download Process Display: Shows inspection results and parameter consistency.
- Switch: Toggles between displaying speed/voltage/current or RPM/Q-axle voltage/D-axle voltage.
- CLR DTC: Clears diagnostic trouble codes.
- Calibration: Adjusts displayed voltage and current to match actual values.
- Weak Flux: Adjusts D-axle voltage and Q-axle current.
- Open File/Download: Imports ECU program or configuration files.


5.4.2 Advanced Interface (Detailed)
This section provides more specific advanced settings.
- Motor Temp Protection: Configures temperature thresholds for power limiting and motor cutoff.
- DAMPING (10-30): Prevents motor auto-rotation failure. High values can cause the motor to stop too fast and produce a current sound.
- Display Speed Adjustment: Used to adjust the speedometer display speed. Fill in multiples of 265.


5.5 Display Page Settings
The display page shows real-time operational data and fault information.
- RPM: Displays motor speed in real-time.
- Voltage: Displays controller voltage in real-time.
- Current: Displays controller current in real-time.
- Fault Code: Displays current fault codes.
- Controller Temp: Displays controller temperature.
- External Temp: Displays motor temperature.
- Temp Coefficient: Displays the controller hardware value.
- Gears: Displays the current gear in real-time.
- Status: Displays the controller status (e.g., IDLE).
- Connection: Indicates if the controller connection is normal.




5.6 Port Interface Settings
The port interface allows assigning specific functions to the controller's physical ports based on vehicle needs. The port function and the setting interface function selection must be consistent.

5.6.1 Example: EM80 Toggle Switch 3 Speed Settings

5.6.2 Example: EM80 Button Switch (Jog Switch) 3 Speed Settings

5.6.3 Example: EM80 Port One Line Speedometer Settings

5.6.4 Example: EM80 Port Hall Speedometer Settings

6. Troubleshooting
This section lists common error codes and their descriptions to assist in diagnosing issues with the controller.
6.1 Error Codes
| Error Code | Description |
|---|---|
| 0x001 | E_BRAKE_ON (Brake) |
| 0x02 | OVER_CURRENT (Hardware overcurrent) |
| 0x04 | UNDER_VOLTAGE (Under voltage) |
| 0x08 | HALL_ERROR (Hall error) |
| 0x10 | OVER_VOLTAGE (Over voltage) |
| 0x20 | MCU_ERROR (Controller error) |
| 0x40 | MOTOR_BLOCK (Motor block error) |
| 0x80 | FOOTPLATE_ERR (Throttle error) |
| 0x100 | SPEED_CONTROL (Run away) |
| 0x200 | WRITING_EEPROM (EEROM writing) |
| 0x800 | START_UP_FAILURE (Quality inspection failure) |
| 0x1000 | OVERHEAT (Controller overheat) |
| 0x2000 | OVER_CURRENT1 (Software overcurrent) |
| 0x4000 | ACCELERATE_PADAL_ERR (Throttle failure) |
| 0x8000 | ICS1_ERR (Current sensor error 1) |
| 0x10000 | ICS2_ERR (Current sensor error 2) |
| 0x20000 | BREAK_ERR (Brake failure) |
| 0x40000 | HALL_SEL_ERROR (Hall error) |
| 0x80000 | MOSFET_DRIVER_FAULT (Driver failure) |
| 0x100000 | MOSFET_HIGH_SHORT (MOS tube short circuit) |
| 0x200000 | PHASE_OPEN (Phase wire connection failure) |
| 0x400000 | PHASE_SHORT (Phase wire short circuit) |
| 0x800000 | MCU_CHIP_ERROR (Controller failure) |
| 0x1000000 | PRE_CHARGE_ERROR (Pre-charge failure) |
| 0x8000000 | OVERHEAT1 (Motor overheat) |
| 0x80000000 | SOC_ZERO_ERROR (SOC 0 error) |

| Error Code | Description |
|---|---|
| 0x24 | MCU_CHIP_ERROR (Controller error) |
| 0x12 | FOOTPLATE_ERR (Throttle error) |
| 0x42 | OVER_CURRENT (Over current) |
| 0x13 | HALL_ERROR (Hall error) |
| 0x22 | MAIN_RELAY_DRIVER (Relay driver error) |
| 0x14 | UNDER_VOLTAGE (Under voltage) |
| 0x21 | OVERHEAT (Controller overheat) |
| 0x23 | CAN_COMMUNICATION_TIMEOUT (CAN communication timeout) |
| 0x25 | PRE_CHARGE_ERROR (Pre-charge error) |
| 0x31 | SPI_COMMUNICATION_ERRO (Sensor communication error) |
| 0x32 | ANGLE_SENSER_ERROR (Sensor error) |
| 0x33 | OVERHEAT1 (Motor overheat) |
| 0x34 | OVERHEAT2 (Radiator overheat) |
| 0x35 | MOTOR_BLOCK (Motor block error) |
| 0x43 | MAIN_RELAY_FAULT (Relay error) |
| 0x11 | OTHER |

7. User Tips
- Software and Manuals: Always contact the seller to obtain the latest software and user manuals (including passwords if applicable) before or upon receiving your controller.
- Motor Compatibility: While the controller generally matches well with QS Motors, if you intend to use it with a new brand motor, be prepared to test and adjust some parameters yourself for optimal performance.
- Debugging Cable Usage: Never plug or unplug the USB debugging cable when the controller is powered on to prevent potential damage.
- Parameter Consistency: Ensure that the port functions configured in the software are consistent with the physical wiring and intended use.
8. Maintenance
To ensure the longevity and reliable performance of your VOTOL EM180GTS SV200 controller, follow these general maintenance guidelines:
- Keep Dry: The controller has an IP67 waterproof rating, but it is always best to avoid prolonged exposure to water or extreme moisture.
- Clean Connections: Periodically inspect all wiring connections for corrosion, looseness, or damage. Ensure they are clean and securely fastened.
- Temperature Monitoring: Regularly monitor the controller's temperature, especially during heavy use. Ensure adequate airflow around the controller to prevent overheating.
- Software Updates: Check for any available software or firmware updates from the manufacturer to ensure optimal performance and bug fixes.
- Physical Inspection: Visually inspect the controller for any physical damage, cracks, or signs of wear.
9. Warranty and Support
For after-sale analysis and detailed support, please refer to the official documentation provided by the manufacturer. A comprehensive user manual in PDF format is available for download.
You can access the PDF user manual here: VOTOL EM180GTS SV200 User Manual (PDF)
For specific after-sale analysis data, refer to the '售后故障数据 库.xlsx' file, which contains detailed fault data.