VOTOL EM180GTS SV200

Contents

VOTOL EM180GTS SV200 Electric DC Hall Motor Speed Controller User Manual

Model: EM180GTS SV200 | Brand: VOTOL

1. Introduction

The VOTOL EM180GTS SV200 is a sine wave type brushless DC controller designed for electric scooters and motorcycles. It features flux-weakening capabilities and is generally compatible with QS Motors. For new brand motors, some parameters may require self-testing and adjustment.

This manual provides detailed instructions for wiring, software connection, parameter configuration, and troubleshooting to ensure optimal performance and safe operation of your controller.

2. Package Contents

Each set of the VOTOL EM180GTS SV200 controller typically includes the following components:

Combo 1 (CAN BUS Version)

  • 1 x EM180GTS/SV200 Sine Wave Controller with CAN BUS
  • 1 x USB Programmable Cable
  • 1 set x Plug-in (matching controller harness plug)

Combo 2 (One-LIN Version)

  • 1 x EM180GTS/SV200 Sine Wave Controller with One-LIN
  • 1 x USB Programmable Cable
  • 1 set x Plug-in (matching controller harness plug)
VOTOL EM180GTS SV200 Controller and wiring harness components
Figure 2.1: Components included in a typical package for the VOTOL EM180GTS SV200 controller.
VOTOL EM180GTS SV200 Controller and wiring harness components
Figure 2.2: Alternative view of the controller and its accompanying wiring harnesses.

3. Specifications

The VOTOL EM180GTS SV200 controller offers robust performance and features for electric vehicle applications.

FeatureSpecification
Brand NameVOTOL (FARDRIVER)
ModelEM180GTS SV200
OriginMainland China
Rated Voltage72V
Rated DC Current160A
Peak Phase Current490A
Boost DC Current250A
Rated Power3-5KW
Max. Efficiency≥93%
Flux Weakening200%
Waterproof GradeIP67
Net Weight1.2KG
Dimensions (L x W x H)186mm x 107mm x 60mm (approx.)
Infographic of VOTOL EM180GTS SV200 specifications
Figure 3.1: Key specifications of the VOTOL EM180GTS SV200 controller.
Technical drawing with dimensions of the SV-200 controller
Figure 3.2: Dimensional drawing of the VOTOL SV-200 controller.
Performance graph and table for EM180GTS/SV200 with QS 138 4000W Mid Drive Motor
Figure 3.3: Test report showing performance characteristics (efficiency, power, torque) when paired with a QS 138 4000W Mid Drive Motor.

4. Setup and Installation

4.1 Wiring Instructions

Proper wiring is crucial for the safe and correct operation of the controller. Refer to the diagrams and descriptions below for connecting the main functions and various components.

SIAECOSYS 2x8 main function wiring diagram
Figure 4.1.1: Main function wiring diagram for SIAECOSYS 2x8 connectors. Technical requirements include 0.3mm2 wire gauge, phospher bronze terminals, specific wire lengths, reinforced nylon plastic, and pull-out forces for terminals and plugs.
Detailed wiring harness with labeled connectors
Figure 4.1.2: Detailed view of the wiring harness with labeled connectors for various functions including throttle, debugging, E-lock, speed switch, low brake, anti-theft, and Hall sensor.

4.1.1 E-lock Connector

Connect the grey/purple E-lock wire to the ignition key. This controls the power to the controller.

E-lock connector wiring diagram
Figure 4.1.3: E-lock connector (grey/purple) wiring, connecting to the ignition key.

4.1.2 Throttle Connector

Connect the throttle connector to the throttle, display, and brake system.

  • Throttle 5V+ (Pink): Connects with throttle.
  • Throttle - (Black): Connects with throttle.
  • Throttle Signal (Green): Connects with throttle.
  • Display Signal (White): Connects with display.
  • Brake Signal (Purple): Connects with 12V brake.
Throttle connector wiring diagram
Figure 4.1.4: Throttle connector wiring, showing connections for throttle, display, and brake.

4.1.3 Gears Connector

Connect the gears connector to the gears switch. Ensure the negative wire is properly connected.

  • Gear 3 (Black/white)
  • Negative - (Black)
  • Gear 1 (Green/white)
  • Gear Sport (Yellow/white)
  • Gear Park (Brown/white)
Gears connector wiring diagram
Figure 4.1.5: Gears connector wiring, showing connections to the gears switch.

4.1.4 Back & Kick Stand Connector

Connect the back switch and kick stand switch.

  • Back (Grey/white): Connect to GND. Press the button and apply throttle for reversing rotation.
  • Kick Stand (Grey/black): Connect to GND.
Back & kick stand connector wiring diagram
Figure 4.1.6: Back & kick stand connector wiring, showing connections for reverse and kick stand functions.

4.1.5 Restore Connector

Connect the restore button.

  • Restore (Brown): If throttle and brake errors occur, double-press and then long-press for 2 seconds to activate the restore function.
Restore connector wiring diagram
Figure 4.1.7: Restore connector wiring, showing connection for the restore button.

4.1.6 Debugging Connector

Connect the debugging connector for PC USB cable and Bluetooth connection.

  • 5V (Pink)
  • Negative Pole (Black)
  • Debugging RXD (Blue)
  • Debugging TXD (Orange)

Important: Do not plug or unplug the debugging cable when the controller is powered on.

Debugging connector wiring diagram
Figure 4.1.8: Debugging connector wiring, showing connections for PC USB cable and Bluetooth.

4.1.7 Hall Connector

Connect the Hall sensor wires as per the diagram.

Hall connector wiring diagram
Figure 4.1.9: Hall connector wiring diagram, showing connections for Yellow, Red, Green, Blue, and Black wires.

4.1.8 Anti-theft Connector

Connect the anti-theft system wires.

Anti-theft connector wiring diagram
Figure 4.1.10: Anti-theft connector wiring diagram, showing connections for Negative pole (Black), Positive pole (Red), Power input (Orange), Anti-theft signal input (Blue), and Motor movement signal (Yellow).

4.2 Software Connection Manual

The controller can be connected to a PC for debugging and parameter configuration using a USB debugging cable.

Screenshot of the VOTOL EM-V3 Software Debugging interface
Figure 4.2.1: Overview of the VOTOL EM-V3 Software Debugging interface, showing various parameter pages.

4.2.1 Software Installation

When connecting the controller to the PC with the USB debugging cable, the driver should install automatically. If not, follow these steps:

  1. Decompress the file “USB-to-serial-win10-20150814” and then “YH-340 USB”.
  2. Choose and decompress the correct file based on your PC system (WIN7/WIN8/WIN10).
  3. Open Device Manager, navigate to “COM and LPT”, right-click the port with an exclamation mark, and select “Update the driver software”.
  4. Browse your computer for driver software and select the appropriate driver (e.g., 3.3.10.140 (2009-11-19) version).
  5. After successful installation, the port should appear without an exclamation mark. If not, reconnect the USB debugging cable.
Software installation steps for VOTOL controller
Figure 4.2.2: Screenshot illustrating the software installation process, including decompression and driver update steps.
Device Manager screenshot for driver update
Figure 4.2.3: Screenshot of Device Manager, showing how to locate and update the driver for the Prolific USB-to-Serial Comm Port.
Driver selection for PL2303HXA
Figure 4.2.4: Screenshot showing the selection of the correct driver version (e.g., 3.3.10.140) for PL2303HXA in Device Manager.

4.2.2 Connecting Debugging Cable

Select the correct USB debugging cable (CAN or One-LIN version) and connect it to the PC and controller.

  • For CAN Version: Use the specific CAN debugging cable.
  • For One-LIN Version: Use the specific One-LIN debugging cable.
USB programmable cable for CAN Version
Figure 4.2.5: USB programmable cable for the CAN Bus version of the controller.
USB programmable cable for One-LIN Version
Figure 4.2.6: USB programmable cable for the One-LIN version of the controller.

Once connected, open the PC controller software. Choose the correct baud rate (9600 for LIN, 115200 for CAN) and click “connect”. Ensure the controller is powered on. All parameters will then be displayed in the software.

Connecting debugging cable with controller and PC
Figure 4.2.7: Steps for connecting the debugging cable, selecting baudrate, and connecting to the software.
Connecting debugging cable with CAN function
Figure 4.2.8: Steps for connecting the debugging cable for CAN function, selecting baudrate (115200), and connecting to the software.

If the controller cannot be connected, enter the advanced interface by typing “~” and pressing “shift”. In the advanced interface, choose the correct CAN baud rate and ID based on the controller model. Observe the values; when they rise, click page 1 to connect the controller.

Advanced interface for software connection
Figure 4.2.9: Screenshot of the advanced interface for software connection, showing options for CAN baudrate and ID selection.

5. Operating Parameters

The controller software allows for detailed configuration of various operating parameters. This section describes the settings available on different pages of the software interface.

Parameter setting description for Page 1
Figure 5.1: Overview of Parameter Page 1, showing basic settings, language switch, CAN baudrate, and connection steps.

5.1 Parameter Page 1

This page contains basic settings for voltage, current, and throttle response.

5.1.1 Voltage Settings

Configure overvoltage, undervoltage, and soft undervoltage parameters. These settings are crucial for battery protection.

  • Battery Voltage (V): Select the controller's working voltage range.
  • Overvoltage (V): Protection against excessive voltage.
  • Undervoltage (V): Protection against low voltage.
  • Soft Undervoltage (V): Reduces power and speed to protect the battery when voltage drops.
  • Undervoltage Variation: Defines the voltage recovery threshold after an undervoltage fault.
Parameter setting description for Page 1, Voltage settings
Figure 5.1.1: Detailed view of voltage settings on Parameter Page 1, including overvoltage, undervoltage, and soft undervoltage.

5.1.2 Current Settings

Adjust regenerative and phase current limits.

  • Regenerative (A): Set according to the maximum reverse charge current the battery can handle. Set to 0 if the battery does not support reverse charging.
  • Phase Current: Set according to the maximum phase current value provided by the technical department. High values can lead to overheating.
Parameter setting description for Page 1, Current settings
Figure 5.1.2: Detailed view of current settings on Parameter Page 1, including regenerative current and phase current.

5.1.3 Throttle Voltage Settings

Configure the throttle's voltage range and protection levels.

  • Throttle Voltage Set: Define the actual lowest and highest voltage of your throttle.
  • Low Protect: Prevents throttle errors if the signal voltage is too low during power-on.
  • Start Voltage: Minimum voltage for the motor to start running.
  • End Voltage: Maximum voltage for full output.
  • High Protect Value: Stops the motor if throttle voltage exceeds this value.
Parameter setting description for Page 1, Throttle voltage settings
Figure 5.1.3: Detailed view of throttle voltage settings on Parameter Page 1, including low protect, start voltage, end voltage, and high protect value.

5.1.4 Start Torque Settings

Adjust the motor's starting torque and delay.

  • Start Torque: Usually set to 0.
  • Combinative Torque: Controls the starting delay (0-350). Higher values mean more obvious delay.

These settings are particularly suitable for mid-drive motors with gearboxes to manage gear backlash.

Parameter setting description for Page 1, Start torque settings
Figure 5.1.4: Detailed view of start torque settings on Parameter Page 1, including start torque and combinative torque.

5.1.5 Rate of Rise and Decline

Control the acceleration and deceleration characteristics.

  • Rate of Rise: (10-255) Higher values result in faster acceleration.
  • Rate of Decline: (10-200) Higher values result in more obvious speed drop and reduced throttle inertia.
Parameter setting description for Page 1, Rate of rise and decline settings
Figure 5.1.5: Detailed view of rate of rise and decline settings on Parameter Page 1.

5.2 Parameter Page 2

This page includes settings for flux-weakening, speed limits, and multi-speed modes.

5.2.1 Current/Flux-Weakening Settings

Adjust the maximum current and flux-weakening parameters.

  • Max Current (A): Should be set under engineer guidance.
  • Flux-Weakening: Broadens the speed range of permanent magnet synchronous motors. Higher values increase motor speed.
  • KI Setting: Adjusts motor high-speed jitter. Increase to reduce jitter, decrease if no jitter.
  • Automatic Logout Enablers:
    • Logout Time (S): For S mode, automatically reduces speed and current to protect the battery.
    • Recovery Time (S): Gap time for the second S mode function to prevent prolonged S mode operation.
Parameter setting description for Page 2, Flux-weakening settings
Figure 5.2.1: Detailed view of current and flux-weakening settings on Parameter Page 2.

5.2.2 Constant Speed/HHC (Hill Hold Control)

Enable or disable constant speed and hill hold functions.

  • HHC Enable: Enables or disables the slope stop function.
  • Constant Speed: Keeps motor speed constant within the maximum power range.
  • Max. Limited RPM: Set equal to the motor landing speed.
Parameter setting description for Page 2, Speed limit settings
Figure 5.2.2: Detailed view of constant speed and HHC settings on Parameter Page 2.

5.2.3 Three-Speed Settings

Configure the current limits and default gear for three-speed modes.

  • Low (%), Mid (%), Hige (%): Set current ratios for each speed mode.
  • Start Phase Current: Maximum phase current limit for the first acceleration section.
  • KP: Adjusts motor sound and resonance during starting.
  • Three Speed Default Gear: Select the power-on default gear.
  • Soft Start: Unchecked for hard start. Higher grade means more power at start.
Parameter setting description for Page 2, Three-speed settings
Figure 5.2.3: Detailed view of three-speed settings on Parameter Page 2.

5.3 Parameter Page 3

This page covers motor-specific settings, speedometer communication, and braking functions.

5.3.1 Motor Settings

Configure parameters specific to your motor type.

  • Pole Pairs: Set according to your motor's pole pairs. Incorrect values affect motor speed.
  • Exchange Hall Wire Color (Yellow-Blue): Decides motor rotation direction.
  • Exchange Phase Wire Color (Blue-Green): Decides motor rotation direction.
  • Hall Shift Angle: Set according to motor specifications (e.g., -60 for hub motors).
  • Motor Type: Select 'surface-mount' for hub motors or 'V-type' for mid-drive motors.
Parameter setting description for Page 3, Motor settings
Figure 5.3.1: Detailed view of motor settings on Parameter Page 3, including pole pairs, Hall/phase wire exchange, Hall shift angle, and motor type.

5.3.2 Speedometer and Cruise Control

Configure speedometer communication and cruise control functions.

  • Out-put (One-Lin / Hall Speedometer): Select communication method.
  • Cruise: Enable or disable cruise function.
  • Moving Vehicle Booster: Function for 2-wheelers, adjusts speed ratio and torque.
  • Double-Voltage Automatic Identification Setting: Single voltage as default.
Parameter setting description for Page 3, Speedometer and Cruise settings
Figure 5.3.2: Detailed view of speedometer communication, cruise function, and booster settings on Parameter Page 3.

5.3.3 Braking and Secure Boot

Adjust reverse speed limits and electric braking.

  • Reversing the Speed Limit (%): Sets the maximum speed in reverse.
  • EBS Ratio (%): Sets electric brake regeneration power. Adjust for comfort when releasing handlebars and braking.
  • Low Brake: Enables low brake signal.
  • Secure Boot: Special soft function, off by default.
Parameter setting description for Page 3, Reverse speed and braking settings
Figure 5.3.3: Detailed view of reverse speed limit, EBS ratio, low brake, and secure boot settings on Parameter Page 3.

5.4 Advanced Page Settings

The advanced page provides additional diagnostic and configuration options.

Parameter setting description for Advanced page overview
Figure 5.4.1: Overview of the advanced settings page, showing navigation from basic parameter pages.

5.4.1 Remote Control Interface

This interface allows for remote control and local control switching, as well as analog input monitoring.

  • Download Process Display: Shows inspection results and parameter consistency.
  • Switch: Toggles between displaying speed/voltage/current or RPM/Q-axle voltage/D-axle voltage.
  • CLR DTC: Clears diagnostic trouble codes.
  • Calibration: Adjusts displayed voltage and current to match actual values.
  • Weak Flux: Adjusts D-axle voltage and Q-axle current.
  • Open File/Download: Imports ECU program or configuration files.
Parameter setting description for Advanced page, Display settings
Figure 5.4.2: Detailed view of the remote control interface, including download process display, display switch, and calibration options.
Parameter setting description for Advanced page, Calibration
Figure 5.4.3: Summary of calibration functions on the advanced page, including voltage, current, weak flux, and file operations.

5.4.2 Advanced Interface (Detailed)

This section provides more specific advanced settings.

  • Motor Temp Protection: Configures temperature thresholds for power limiting and motor cutoff.
  • DAMPING (10-30): Prevents motor auto-rotation failure. High values can cause the motor to stop too fast and produce a current sound.
  • Display Speed Adjustment: Used to adjust the speedometer display speed. Fill in multiples of 265.
Parameter setting description for Advanced interface, Temperature protection
Figure 5.4.4: Detailed view of temperature protection settings, DAMPING, and speedometer display adjustment in the advanced interface.
Parameter setting description for Advanced interface, CAN/Calibration
Figure 5.4.5: Detailed view of CAN mode settings, calibration options, and file operations in the advanced interface.

5.5 Display Page Settings

The display page shows real-time operational data and fault information.

  • RPM: Displays motor speed in real-time.
  • Voltage: Displays controller voltage in real-time.
  • Current: Displays controller current in real-time.
  • Fault Code: Displays current fault codes.
  • Controller Temp: Displays controller temperature.
  • External Temp: Displays motor temperature.
  • Temp Coefficient: Displays the controller hardware value.
  • Gears: Displays the current gear in real-time.
  • Status: Displays the controller status (e.g., IDLE).
  • Connection: Indicates if the controller connection is normal.
Parameter setting description for Display page, RPM/Voltage/Current
Figure 5.5.1: Real-time display of RPM, Voltage, and Current on the Display page.
Parameter setting description for Display page, RPM/Q-axle voltage/D-axle voltage
Figure 5.5.2: Display of RPM, Q-axle voltage, and D-axle voltage on the Display page.
Parameter setting description for Display page, RPM/Q-axle current/D-axle current
Figure 5.5.3: Display of RPM, Q-axle current, and D-axle current on the Display page.
Parameter setting description for Display page, Faults/Status
Figure 5.5.4: Display of fault codes, temperatures, gears, and connection status on the Display page.

5.6 Port Interface Settings

The port interface allows assigning specific functions to the controller's physical ports based on vehicle needs. The port function and the setting interface function selection must be consistent.

Parameter setting description for Port interface overview
Figure 5.6.1: Overview of the port interface, showing various port assignments and function branches.

5.6.1 Example: EM80 Toggle Switch 3 Speed Settings

Port interface example for 3-speed settings
Figure 5.6.2: Example configuration for EM80 toggle switch 3-speed settings on the port interface.

5.6.2 Example: EM80 Button Switch (Jog Switch) 3 Speed Settings

Port interface example for jog switch 3-speed settings
Figure 5.6.3: Example configuration for EM80 button switch (jog switch) 3-speed settings on the port interface.

5.6.3 Example: EM80 Port One Line Speedometer Settings

Port interface example for One Line speedometer settings
Figure 5.6.4: Example configuration for EM80 port One Line speedometer settings on the port interface.

5.6.4 Example: EM80 Port Hall Speedometer Settings

Port interface example for Hall speedometer settings
Figure 5.6.5: Example configuration for EM80 port Hall speedometer settings on the port interface.

6. Troubleshooting

This section lists common error codes and their descriptions to assist in diagnosing issues with the controller.

6.1 Error Codes

Error CodeDescription
0x001E_BRAKE_ON (Brake)
0x02OVER_CURRENT (Hardware overcurrent)
0x04UNDER_VOLTAGE (Under voltage)
0x08HALL_ERROR (Hall error)
0x10OVER_VOLTAGE (Over voltage)
0x20MCU_ERROR (Controller error)
0x40MOTOR_BLOCK (Motor block error)
0x80FOOTPLATE_ERR (Throttle error)
0x100SPEED_CONTROL (Run away)
0x200WRITING_EEPROM (EEROM writing)
0x800START_UP_FAILURE (Quality inspection failure)
0x1000OVERHEAT (Controller overheat)
0x2000OVER_CURRENT1 (Software overcurrent)
0x4000ACCELERATE_PADAL_ERR (Throttle failure)
0x8000ICS1_ERR (Current sensor error 1)
0x10000ICS2_ERR (Current sensor error 2)
0x20000BREAK_ERR (Brake failure)
0x40000HALL_SEL_ERROR (Hall error)
0x80000MOSFET_DRIVER_FAULT (Driver failure)
0x100000MOSFET_HIGH_SHORT (MOS tube short circuit)
0x200000PHASE_OPEN (Phase wire connection failure)
0x400000PHASE_SHORT (Phase wire short circuit)
0x800000MCU_CHIP_ERROR (Controller failure)
0x1000000PRE_CHARGE_ERROR (Pre-charge failure)
0x8000000OVERHEAT1 (Motor overheat)
0x80000000SOC_ZERO_ERROR (SOC 0 error)
Error code table 1
Figure 6.1.1: Table of common error codes and their descriptions.
Error CodeDescription
0x24MCU_CHIP_ERROR (Controller error)
0x12FOOTPLATE_ERR (Throttle error)
0x42OVER_CURRENT (Over current)
0x13HALL_ERROR (Hall error)
0x22MAIN_RELAY_DRIVER (Relay driver error)
0x14UNDER_VOLTAGE (Under voltage)
0x21OVERHEAT (Controller overheat)
0x23CAN_COMMUNICATION_TIMEOUT (CAN communication timeout)
0x25PRE_CHARGE_ERROR (Pre-charge error)
0x31SPI_COMMUNICATION_ERRO (Sensor communication error)
0x32ANGLE_SENSER_ERROR (Sensor error)
0x33OVERHEAT1 (Motor overheat)
0x34OVERHEAT2 (Radiator overheat)
0x35MOTOR_BLOCK (Motor block error)
0x43MAIN_RELAY_FAULT (Relay error)
0x11OTHER
Error code table 2
Figure 6.1.2: Additional error codes and their descriptions. Note: High level blinks quickly, low level blinks slowly.

7. User Tips

  • Software and Manuals: Always contact the seller to obtain the latest software and user manuals (including passwords if applicable) before or upon receiving your controller.
  • Motor Compatibility: While the controller generally matches well with QS Motors, if you intend to use it with a new brand motor, be prepared to test and adjust some parameters yourself for optimal performance.
  • Debugging Cable Usage: Never plug or unplug the USB debugging cable when the controller is powered on to prevent potential damage.
  • Parameter Consistency: Ensure that the port functions configured in the software are consistent with the physical wiring and intended use.

8. Maintenance

To ensure the longevity and reliable performance of your VOTOL EM180GTS SV200 controller, follow these general maintenance guidelines:

  • Keep Dry: The controller has an IP67 waterproof rating, but it is always best to avoid prolonged exposure to water or extreme moisture.
  • Clean Connections: Periodically inspect all wiring connections for corrosion, looseness, or damage. Ensure they are clean and securely fastened.
  • Temperature Monitoring: Regularly monitor the controller's temperature, especially during heavy use. Ensure adequate airflow around the controller to prevent overheating.
  • Software Updates: Check for any available software or firmware updates from the manufacturer to ensure optimal performance and bug fixes.
  • Physical Inspection: Visually inspect the controller for any physical damage, cracks, or signs of wear.

9. Warranty and Support

For after-sale analysis and detailed support, please refer to the official documentation provided by the manufacturer. A comprehensive user manual in PDF format is available for download.

You can access the PDF user manual here: VOTOL EM180GTS SV200 User Manual (PDF)

For specific after-sale analysis data, refer to the '售后故障数据 库.xlsx' file, which contains detailed fault data.

After-sale analysis reference
Figure 9.1: Reference to the after-sale analysis document.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.