EARU EASEM-E

Contents

EARU EASEM-E Tuya WiFi Smart Power Energy Meter Instruction Manual

Model: EASEM-E | Brand: EARU

1. Introduction

This manual provides essential information for the safe and efficient operation of your EARU EASEM-E Tuya WiFi Smart Power Energy Meter. Please read it thoroughly before installation and use, and keep it for future reference.

2. Important Safety Instructions

WARNING

This product does not feature an explosion-proof structure and must not be used in flammable environments, such as those containing flammable gases, liquids, or explosives.

SAFETY INFORMATION

  1. Please use this product in accordance with the instructions in this manual.
  2. Do not disassemble this product by yourself.
  3. Pay attention to the rated voltage for use.

3. Product Description

The EARU EASEM-E is an instrument and equipment used to measure, record, display, and analyze parameters related to electric energy. It is widely applied in various stages of the power system, including power generation, transmission, distribution, and consumption.

4. Features

  • Tuya compliant for smart home integration.
  • Supports linkage with other Tuya devices.
  • Compatible with single and three-phase electrical systems.
  • Measures real-time Voltage, Current, Power Factor, Active Power, and Frequency.
  • Supports bi-directional energy usage and production measurement.
  • Provides energy usage/production trends by hour, day, and month.
  • Lightweight and easy to install.
  • Supports Alexa and Google voice control.
  • Features a 16A Dry contact output.
  • Configurable on/off schedule.
  • Overload protection.
  • Power-on status setting.

5. Specifications

AttributeValue
Model NumberEASEM-E
Operating VoltageAC 90-250V
Max Load Current16A Dry contact
Frequency50/60Hz
Wi-Fi802.11 B/G/N20/N40
BLEBluetooth 5.2 Low Energy
Operating Frequency2.4GHz
Operating Temperature-20℃ ~ +55℃
Humidity≤90% non-condensing
Calibrated Metering Accuracy≤100W (Within±2W), >100W (Within±2%)
Dimensions90 (L) x 35 (W) x 65 (H) mm
Max Operating Current19A & Under
Rated Voltage230V
Power SupplyAC
Display TypeAnalog Only
CertificationCE
FunctionOn-off function

For detailed dimensions, refer to the diagram below:

Product dimensions diagram showing length, width, and height in millimeters and inches.

6. Package Contents

Upon opening the package, please verify that all items are present:

  • Main Unit (EARU EASEM-E Smart Power Meter) x 1
  • CT Clamps (Current Transformers) x 3
  • Instruction Manual x 1
  • Screwdriver x 1

7. Setup

7.1. App Connection

  1. Turn on your phone's WiFi and Bluetooth. Ensure your connected WiFi network is on the 2.4GHz band.
  2. Open the Tuya Smart Life APP. Tap '+' in the upper right corner of the APP interface and click 'Add Device'.
  3. The app should detect the device. Clicking on the device pop-up will automatically initiate connection.
  4. Enter the password of your connected WiFi network and click 'Next'.
  5. When the device is connecting, the indicator light will flash green and yellow alternately (or red and yellow).
  6. After successfully connecting, the indicator light (green or red) will be continuously on. Click 'Done' to enter the device function interface.

7.2. Wiring Instructions

Always turn off the main power supply before performing any wiring to prevent electric shock.

CT Clamp Direction

The direction of the Current Transformer (CT) clamp is crucial for accurate measurement:

  • To measure energy consumption, the arrow on the CT should follow the direction of the current flow. In this case, the power will be positive, and energy consumption will be accumulated.
  • To measure energy production (e.g., from solar panels), the arrow on the CT should be opposite to the direction of the current flow. In this case, the power will be negative, and energy generation will be accumulated.
Diagram showing CT clamp direction for consumption and production, along with a table of clamp diameters for different amperages.

CT Clamp Diameter Options

Clamp AmperageDiameter
80A (default)10.2mm
120A (optional)16mm
200A (optional)20mm
300A (optional)24.8mm
500A (optional)37.5mm
750A (optional)50mm
1000A (optional)51mm

Wiring Diagrams

Refer to the diagrams below for single-phase and three-phase wiring configurations.

Single Phase electricity wiring diagram showing connections for the power meter, circuit breaker, loads, and inverter.Three Phase electricity wiring diagram showing connections for the power meter, circuit breaker, loads, and inverter. Note: When installing, please ensure that the circuit measured by CT is in the same phase as the circuit powered by Power Meter with Relay.

General Wiring Steps

  1. Turn off Power: Ensure the main power supply to the electrical panel is completely turned off before starting any wiring.
  2. Mount the Main Unit: Securely mount the EARU EASEM-E main unit onto a 35mm DIN rail within your electrical panel.
  3. Connect Power Wires: Connect the N (Neutral), VA (Phase A), VB (Phase B), and VC (Phase C) terminals on the main unit to the corresponding N, A, B, and C wires on your main breaker.
  4. Connect CT Clamps: Connect the wires from each of the three CT clamps to the IA+, IA-, IB+, IB-, IC+, IC- terminals on the main unit, paying close attention to the positive (+) and negative (-) polarity.
  5. Loop CT Clamps: For each phase (A, B, C), loop the corresponding CT clamp around the respective phase wire. Ensure the arrow on the CT clamp points in the correct direction (towards the load for consumption, away from the load for production). Make sure the CT buckle is securely snapped.
  6. Connect Relay (Optional): If using the relay function to control an external contactor, connect the 16A Dry contact terminals on the power meter to the control terminals (e.g., A1 and A2) of your contactor.

8. Operating Instructions

8.1. App Control and Monitoring

Once connected to the Tuya Smart Life APP, you can access various functions:

  • Real-time Monitoring: View live data for total electricity consumption, current, frequency, voltage, current, power factor, and active power for each phase.
  • App screenshot showing real-time viewing of total electricity consumption, current, frequency, voltage, current, power factor, and active power data for each phase.
  • On/Off Control: Control the device's internal relay directly from the app to switch connected loads on or off.
  • History Data: Access daily, monthly, and yearly electricity data for both consumption and production. This data can be exported for further analysis or archiving.
  • App screenshot showing electricity statistics with daily, monthly, and yearly data for both directions (reverse and forward) for each bidirectional channel.
  • Usage Trends: View usage trends of daily, weekly, and monthly energy production measurements.
  • App screenshot showing usage trends for daily, weekly, and monthly energy production measurements, including positive and reverse active power consumption for each phase.
  • Scheduling: Configure automated on/off schedules for the relay.
  • Overload Protection: Set maximum power protection thresholds for each phase to prevent overloads.
  • Power-on Status: Configure the device's state (On/Off/Remember last status) after a power outage.

8.2. Voice Control

The device integrates with popular voice assistants, allowing for hands-free control:

  • Connect the device to your intelligent speaker (e.g., Amazon Alexa, Google Assistant).
  • Use voice commands such as "Alexa, Turn on the power" or "Google, Turn off the power" to control the relay.
Image depicting a user interacting with smart speakers (Alexa and Google Home) to control power via voice commands.

8.3. Manual On/Off

A physical ON/OFF button is located on the device. Press it once to switch the relay ON/OFF manually.

9. Maintenance

  • Keep the device clean and free from dust. Use a dry, soft cloth for cleaning.
  • Regularly check all wiring connections for tightness and integrity to ensure safe and reliable operation.
  • Ensure the operating environment stays within the specified temperature and humidity ranges to prolong the device's lifespan.

10. Troubleshooting

  • No Power/Indicator Off: Check the main power supply to the electrical panel and verify all wiring connections to the device.
  • Wi-Fi Connection Issues:
    • Ensure your router is operating on the 2.4GHz band.
    • Check the Wi-Fi signal strength at the device's location.
    • To reset Wi-Fi information: Press and hold the reset button on the device for 5 seconds until the LED indicator flashes Red 3 times quickly. The LED will then blink, indicating it's ready for pairing.
  • Inaccurate Readings: Verify the CT clamp direction and ensure they are properly looped around the correct wires. Confirm that the CT clamps are securely snapped shut.
  • Relay Not Switching: Check the app settings for any active schedules, overload protection settings, or manual override. If an external contactor is used, verify its wiring and functionality.
Diagram highlighting the LED indicator, 35mm DIN Rail Mounting, and the Reset button & ON/OFF button on the power meter.

11. User Tips

  • For solar panel users, ensure CT clamps are oriented correctly to accurately differentiate between energy consumption and production.
  • Utilize the scheduling feature in the app to automate power control for appliances, which can help in energy saving.
  • Regularly review historical data to identify energy usage patterns and optimize consumption for efficiency.

12. Warranty and Support

For technical support, warranty inquiries, or further assistance, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.