SZYTF Adjustable Time Delay Relay Module

Rate this product if you’ve used it
Contents

SZYTF Multi-function Time Delay Relay Module User Manual

Model: Adjustable Time Delay Relay Module

1. Introduction

The SZYTF Multi-function Time Delay Relay Module is a versatile control unit designed for a wide range of applications. Utilizing a microcontroller as its core, it offers 32 preset functions, allowing users to select specific functionalities based on their needs. This module is suitable for controlling water pumps, motors, lighting strips, solenoid valves, and more.

Key features include:

  • Expanded functionality with 32 modes to meet diverse application requirements.
  • Power supply anti-reverse protection to prevent damage from incorrect wiring.
  • High timing accuracy, adjustable from 0.01 seconds (minimum) to 999 minutes (maximum).
  • Low power consumption mode with an option to turn off the display area.
SZYTF Time Delay Relay Module, showing both cased and bare versions
Figure 1: SZYTF Multi-function Time Delay Relay Module (cased and bare board)

2. Specifications

ParameterValue
Product NameMulti-function Time Delay Relay
Relay Voltage OptionsDC 5V / 12V / 24V (selectable)
Input Voltage (5V version)DC 5V
Input Voltage (12V version)DC 12V
Input Voltage (24V version)DC 24V
Output Load (DC)Max 10A @ 30V DC
Output Load (AC)Max 5A @ 250V AC
Trigger Signal (High Level)5V, 12V, or 24V (matching module version)
Trigger Signal (Low Level)0V
Quiescent Current20mA
Working Current60mA
Operating Temperature-25℃ to 85℃
Power-off MemoryYes
Product WeightApprox. 26g
Product Size (L*W*H)65 x 34.3 x 17.5 mm
Package TypeSMD
ApplicationGeneral purpose module

Note: Manual measurements are for reference only; actual size may vary slightly.

3. Setup and Wiring

Before connecting, ensure you have selected the correct voltage version (5V, 12V, or 24V) for your application. The relay output is a passive contact, meaning it does not supply current but acts as a switch to control the on/off state of a circuit.

3.1 Power Connection

  • Connect the positive power supply to the DC+ terminal.
  • Connect the negative power supply to the DC- terminal.
  • Ensure the input voltage matches the module's specified voltage (e.g., 5V for a 5V module).
Bare relay module showing power input terminals DC+ and DC-
Figure 2: Bare module with power input terminals

3.2 Trigger Signal Connection

  • Connect the trigger signal input to the IN+ terminal.
  • Connect the trigger signal ground to the IN- terminal.
  • The module supports high-level trigger signals (matching the module's voltage) and low-level (0V) trigger signals.

3.3 Load Connection (Relay Output)

The relay provides three output terminals:

  • COM (Common): The common terminal of the relay.
  • NO (Normally Open): The terminal that connects to COM when the relay is active.
  • NC (Normally Closed): The terminal that connects to COM when the relay is inactive.

Connect your load circuit to the appropriate relay terminals based on your desired operation (e.g., connect your device between COM and NO for a normally open switch).

Bare relay module showing relay output terminals COM, NO, NC
Figure 3: Bare module with relay output terminals

4. Operating Instructions

The module features an LED digital display and control buttons for setting various functions and timing parameters.

4.1 Function Selection (32 Modes)

The module offers 32 preset functions. Refer to the detailed programming guide (not provided in this document, typically included with the product or available from the manufacturer) to understand and select the desired function mode (e.g., P-1x, P-2x, P-3x, etc.).

Cased relay module with LED display and control buttons
Figure 4: Cased module showing LED display and control buttons

4.2 Timing Settings

The timing can be set with an accuracy of 0.01 seconds, ranging from a minimum of 0.1 seconds to a maximum of 999 minutes. The display typically shows time in minutes by default. Use the control buttons (usually labeled with arrows or 'SET') to adjust the timing values and units.

Example: To set a 3-second delay, you might need to navigate to a 'seconds' unit setting or adjust the decimal point. For instance, if the display shows 'b3.00', it might represent 3.00 seconds.

4.3 Display Power Saving

The module includes a low power consumption feature that allows you to turn off the LED display area to save power. Consult the full programming guide for instructions on how to enable or disable this feature.

5. User Tips

  • Opto-isolated Version Wiring: For opto-isolated versions, connect the IN- terminal to DC- and add a 2.2kΩ to 10kΩ resistor from DC+ to IN+. A 4.7kΩ resistor is a common choice.
  • Triggering with Push Button: When using a momentary push button, connect it to trigger the module (e.g., between IN+ and a signal source). For some modes, the timer cycle may start when the button is released.
  • Decimal Point Adjustment: When setting timing, especially for shorter durations, pay attention to the decimal point. Use the 'K4' button (or equivalent on your module) to shift the decimal point for finer control (e.g., to change '3.00' minutes to '3.00' seconds).
  • Programming Manual: While this document provides general instructions, a detailed programming manual is crucial for understanding all 32 modes and advanced settings. If not included, check the seller's product page or contact them for the specific manual.

6. Maintenance

  • Keep the module clean and free from dust and moisture.
  • Avoid exposing the module to extreme temperatures or direct sunlight.
  • Ensure all connections are secure and free from corrosion.
  • Do not attempt to modify the internal circuitry unless you are a qualified professional.

7. Troubleshooting

  • Module not powering on:
    • Check power supply connections (DC+ and DC-).
    • Verify that the input voltage matches the module's voltage version.
    • Ensure power supply anti-reverse protection has not been triggered by incorrect wiring.
  • Relay not activating/deactivating:
    • Check trigger signal connections (IN+ and IN-).
    • Verify the trigger signal level (high or low) is correct for the selected mode.
    • Ensure the timing parameters are set correctly and the module is in the desired operating mode.
    • Check the load connections to the COM, NO, and NC terminals.
  • Incorrect timing:
    • Review the timing settings and ensure the decimal point is correctly positioned for seconds, minutes, etc.
    • Confirm the selected function mode (P-xx) corresponds to the desired timing behavior.

8. Warranty and Support

For warranty information, technical support, or detailed programming guides, please refer to the product listing on the seller's platform or contact the seller directly. Keep your purchase records for any warranty claims.

9. Product Video

Play video
Watch video online
Video 1: Product demonstration of the SZYTF Time Delay Relay Module.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?