This PowMr 4.2KW Hybrid Solar Inverter is a multi-function inverter/charger, combining the functionalities of an inverter, solar charger, and battery charger. It is designed to provide uninterruptible power support in a portable size. The comprehensive LCD display allows for user-configurable and easy-to-access button operations, including battery charging current, AC/solar charger priority, and acceptable input voltage settings tailored to various applications.

Video: Unboxing and overview of the PowMr 4.2KW Hybrid Solar Inverter, highlighting its key features and components.

2. Features

  • Pure sine wave inverter output.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Automatic restart function when AC power recovers.
  • Comprehensive protection against overload, over temperature, and short circuit.
  • Smart battery charger design for optimized battery performance.
  • Cold start function for reliable operation.

3. Specifications

General Specifications
AttributeValue
Brand NamePowMr
Model NumberPOW-HVM4.2M-24V-N
Output Power1 - 200 KW
Size358x442x116 mm
Output TypeSINGLE
Weight8.9kg
Output Frequency50HZ/60HZ
Is Smart DeviceYes
OriginMainland China
CertificationCE
System ConfigurationPhotovoltaic Hybrid Solar Inverter
Output Voltage WaveformPure Sine Wave
Rated output power4.2KVA/4.2KW
Output Voltage230VAC
Battery Voltage24VDC
Maximum PV input power6200W
PV Array MPPT Voltage Range60VDC-500VDC
ApplicationHome solar system
Load typeHousehold appliances, farm tools
FeatureBuilt-in MPPT Solar Charge Controller
Item TypeMPPT Solar Inverter
Battery Type CompatibilityLithium Batteries, Flooded Batteries, Gel Batteries, User Mode, Lead-acid Batteries, AGM Batteries

3.1. Line Mode Specifications

ParameterValue
Input Voltage WaveformPure Sine Wave (Utility or Generator)
Nominal Input Voltage230Vac
Max AC Input Voltage300Vac
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

3.2. Inverter Mode Specifications

ParameterValue
Rated Output Power4.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50HZ
Peak Efficiency93%
Overload Protection3s@≥150% load; 5s@101%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24VDC
Cold Start Voltage23.0VDC
No Load Power Consumption30W

3.3. Charge Mode Specifications

ParameterValue
Charging Algorithm3-Step
AC Charging Current (Max)100A
Max. PV Array Power6200W
Nominal PV Voltage240VDC
PV Array MPPT Voltage Range60VDC~500VDC
Max. PV Array Open Circuit Voltage500VDC
Max Charging Current (AC charger plus solar charger)120A

3.4. Grid-Tie Operation Specifications

ParameterValue
Nominal Output Voltage220/230/240VAC
Feed-in Grid Voltage Range195-253VAC
Feed-in Grid Frequency Range49-51±1Hz/59-61±1Hz
Nominal Output Current18.2A
Maximum Conversion Efficiency (DC/AC)97%

3.5. Two Load Output Power

ParameterValue
Full Load4200W
Maximum Main Load4200W
Maximum Second Load (battery model)1400W
Main Load Cut Off Voltage26VDC
Main Load Return Voltage27VDC

4. Setup

Before installation, ensure all components are present and undamaged. The package includes the inverter device and a user manual. Carefully unpack the inverter and inspect it for any signs of damage during transit.

4.1. System Configuration Diagram

Hybrid Power System Wiring Diagram

Diagram: This diagram illustrates a typical hybrid power system setup. The inverter connects to solar panels (PV Array), a battery bank (24V lithium or lead-acid), and can draw power from a generator or utility grid. It provides single-phase 230V output to home appliances.

  • Solar Power: Max. VOC: 500V DC. PV Array MPPT Voltage Range: 60-450V DC. Max. PV Array Power: 6200W.
  • Max Charging Current: 120A (AC charger + solar charger).
  • Battery: Compatible with 24V lithium battery and lead-acid battery.
  • Output: Single phase 230V output, 4.2KW, for home appliances.

4.2. Battery Compatibility

The inverter is compatible with multiple battery types, including AGM, GEL, FLD (Flooded), LI (Lithium), SLD, and USER-defined modes. When solar energy is present, setting the battery type to LIB will activate the lithium battery after 3 seconds.

Battery Type Compatibility

Image: Visual representation of compatible battery types: AGM, GEL, FLD (Flooded), LI (Lithium), SLD, and USER-defined.

5. Operating Instructions

The inverter features a comprehensive LCD display for user interaction and configuration. All settings can be adjusted via the buttons on the LCD panel.

5.1. Configurable Settings via LCD Display

LCD Display Settings

Image: The LCD display allows configuration of various parameters, including AC/Solar charger priority, battery charging current, and input voltage range for different applications.

5.2. Multiple Charging and Output Modes

The inverter supports various charging and output modes to optimize power management based on availability and priority.

Multiple Charging and Output Modes

Diagram: This diagram illustrates the different charging and output modes:

  • Three Battery Charging Modes: Solar priority, Solar + Utility, Only Solar.
  • Output Modes: Solar priority, Utility priority, SBU mode.

6. Maintenance

To ensure optimal performance and longevity of your PowMr Hybrid Solar Inverter, regular maintenance is recommended:

  • Keep the inverter clean and free from dust and debris. Ensure ventilation openings are not blocked.
  • Periodically check all electrical connections for tightness and signs of corrosion.
  • Monitor the LCD display for any error codes or unusual readings. Refer to the troubleshooting section if issues arise.
  • Ensure the battery bank is maintained according to the manufacturer's specifications for the specific battery type used.
  • Avoid exposing the inverter to direct sunlight, excessive heat, or moisture.

7. Troubleshooting

If you encounter issues with your PowMr Hybrid Solar Inverter, please refer to the following general troubleshooting steps. For specific error codes or complex problems, consult the detailed manual provided with the product or contact customer support.

  • No Power/Display Off: Check all power connections, including AC input, battery connections, and PV input. Ensure the main power switch is ON.
  • Inverter Not Outputting AC: Verify that the battery voltage is within the operating range. Check for overload or short circuit conditions. Ensure the output mode is correctly configured.
  • Battery Not Charging: Check PV input voltage and current. Ensure AC input is present if utility charging is enabled. Verify battery type settings on the LCD.
  • Overload Protection Triggered: Reduce the load connected to the inverter. Check for any faulty appliances causing excessive current draw.
  • Over Temperature Warning: Ensure adequate ventilation around the inverter. Clear any obstructions from the cooling fans.

8. User Tips

  • Always ensure proper grounding for safety during installation and operation.
  • Regularly monitor the LCD display for system status and performance indicators.
  • When configuring battery settings, accurately select your battery type to ensure optimal charging and discharge cycles, prolonging battery life.
  • Consider installing a remote monitoring module (if available for your model) to track performance and receive alerts from anywhere.

9. Warranty and Support

The PowMr 4.2KW Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. For any technical assistance, warranty claims, or support inquiries, please contact your seller or PowMr customer service. Ensure you have your purchase details and product model number available when contacting support.

Warranty and Service Information

Image: This image confirms a 1-year warranty for all products from the store.


Related Documents - POW-HVM4.2M-24V-N

Preview PowMr Hybrid Inverter User Manual - POW-HVM Series
Comprehensive user manual for PowMr POW-HVM series hybrid inverters, covering installation, operation, safety, specifications, and troubleshooting for models POW-HVM6.2M-48V-N, POW-HVM4.2M-24V-N, and POW-HVM3.6M-24V-N.
Preview PowMr HYBRID INVERTER User Manual: POW-HVM Series
Comprehensive user manual for the PowMr HYBRID INVERTER series (POW-HVM3.6M, POW-HVM4.2M, POW-HVM6.2M). Covers installation, operation, safety guidelines, technical specifications, and troubleshooting for efficient power management.
Preview POW-HVM Series Hybrid Inverter User Manual
Comprehensive user manual for the POW-HVM Series Hybrid Inverter, covering installation, operation, maintenance, and troubleshooting. Learn about features like pure sine wave output, configurable input voltage, and smart battery charging.
Preview PowMr Hybrid Inverter User Manual for POW-HVM Series
Comprehensive user manual for PowMr POW-HVM6.2M-48V-N, POW-HVM4.2M-24V-N, and POW-HVM3.6M-24V-N hybrid inverters. Includes installation, operation, LCD settings, specifications, troubleshooting, and maintenance guidelines for optimal performance and safety.
Preview PowMr Hybrid Inverter User Manual: Installation, Operation, and Troubleshooting
Comprehensive user manual for PowMr Hybrid Inverters (models POW-HVM6.2M-48V-N, POW-HVM4.2M-24V-N, POW-HVM3.6M-24V-N), covering installation, operation, specifications, and troubleshooting.
Preview PowMr Hybrid Inverter User Manual - POW-HVM Series
Comprehensive user manual for the PowMr POW-HVM series hybrid inverters, covering installation, operation, specifications, safety instructions, and troubleshooting. Includes details on models POW-HVM6.2M-48V-N, POW-HVM4.2M-24V-N, and POW-HVM3.6M-24V-N.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.