1. Introduction
This PowMr 3.2KW Hybrid Solar Inverter is a versatile multi-function inverter/charger designed to provide uninterruptible power support. It integrates the functions of an inverter, a solar charger, and a battery charger into a compact and portable unit. The comprehensive LCD display allows users to configure various settings, including battery charging current, AC/solar charger priority, and acceptable input voltage, to suit different application requirements.
2. Features
- Pure sine wave output for sensitive electronics.
- Configurable input voltage range for home appliances and personal computers via LCD settings.
- Configurable battery charging current based on applications via LCD settings.
- Configurable AC/Solar Charger priority via LCD settings.
- Compatible with both mains voltage and generator power sources.
- Automatic restart function upon AC recovery.
- Comprehensive protection features: Overload, Over-temperature, Short-circuit, Low Voltage, High Voltage.
- Smart battery charger design for optimized battery performance and longevity.
- Cold start function for reliable operation in various conditions.
- Optional WIFI/GPRS communication module for remote monitoring.
- Supports connection to various battery types, including Lithium-ion and Lead-acid batteries.
- Intelligent cooling fan with a built-in sensor chip that adjusts rotation speed based on ambient temperature.
3. Product Overview







Product Video Overview
Watch this video for an unboxing and detailed overview of the PowMr 3.2KW Hybrid Solar Inverter.
4. Specifications
| Category | Parameter | Value |
|---|---|---|
| Line Mode | Input Voltage Waveform | Pure Sine Wave (Utility or Generator) |
| Nominal Input Voltage | 230VAC | |
| Max AC Input Voltage | 300VAC | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
| Output Frequency | 50Hz/60Hz (Auto-detection) | |
| Utility Charging Mode | Charging Algorithm | 3-Step |
| AC Charging Current (Max) | 60A | |
| MPPT Solar Charging Mode | Max. PV Array Power | 3000W |
| Nominal PV Voltage | 240VDC | |
| PV Array MPPT Voltage Range | 30~400VDC | |
| Max. PV Array Open Circuit Voltage | 400VDC | |
| Combined Charging | Max Charging Current (AC charger + solar charger) | 80A |
| Inverter Mode | Rated Output Power | 3.2KVA/3.0KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230VAC±5% | |
| Peak Efficiency | 94% | |
| Overload Protection | 5s@ >150% load; 10s@ 110% ~ 150% load | |
| Surge Capacity | 2 * rated power for 5 seconds | |
| Nominal DC Input Voltage | 24VDC | |
| Cold Start Voltage | 23.0VDC | |
| Low DC Warning Voltage | 22.0VDC | |
| Low DC Cut-off Voltage | 20.5VDC | |
| General | Safety Certification | CE |
| Operating Temperature Range | -10°C to 55°C | |
| Storage Temperature | -15°C ~ 60°C | |
| Dimension (D*W*H) | 357 x 273 x 95 mm | |
| Net Weight | 4.8 kg |


5. Setup Instructions
Safety Precautions: Before installation, ensure all power sources are disconnected. Always wear appropriate personal protective equipment. Installation should be performed by qualified personnel.
- Mounting: Choose a suitable location for the inverter. It should be a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure sufficient clearance around the inverter for proper airflow.
- Battery Connection: Connect the battery bank to the inverter's Battery Input terminals (10). Ensure correct polarity (+ to + and - to -). Use appropriate cable gauges and fuses as per local regulations and inverter specifications. The inverter supports 24VDC battery systems.
- PV Array Connection: Connect your solar panels (PV array) to the inverter's PV Input terminals (9). Ensure the PV array voltage and current are within the inverter's specified MPPT voltage range (30-400VDC) and maximum input power (3000W). Observe correct polarity.
- AC Input Connection (Utility/Generator): Connect the AC utility grid or a generator to the inverter's AC Input terminals (7). This allows the inverter to charge batteries from AC sources and provide bypass power.
- AC Output Connection (Loads): Connect your household appliances or other loads to the inverter's AC Output terminals (8). Ensure the total load does not exceed the inverter's rated output power (3.2KVA/3.0KW).
- Communication Port (Optional): If using the optional WIFI/GPRS module, connect it to the Communication Port (11) for remote monitoring.
- Grounding: Ensure the inverter is properly grounded according to local electrical codes.

6. Operating Instructions
- Power On: After all connections are secure, switch on the Power On/Off Switch (6). The LCD Display (1) will illuminate, and the Status Indicator (2) will show the current operating mode.
- LCD Display and Function Buttons: Use the Function Buttons (5) to navigate through the LCD display menus. You can view system status, adjust settings, and monitor performance. Refer to the detailed user manual for specific menu navigation.
- Configuring Settings:
- Input Voltage Range: Set the acceptable input voltage range for your appliances or personal computers.
- Battery Charging Current: Adjust the battery charging current based on your battery type and capacity.
- AC/Solar Charger Priority: Configure whether the inverter prioritizes AC power or solar power for charging the batteries.
- Cold Start Function: The inverter supports a cold start function, allowing it to power on directly from batteries even without an AC input or solar power, provided the battery voltage is above 23.0VDC.
- Monitoring: Regularly check the LCD display for system status, charging status (3), and any fault indications (4).
7. Maintenance
- Regular Cleaning: Keep the inverter's exterior clean and free from dust and debris. Ensure ventilation openings are not blocked.
- Connection Checks: Periodically inspect all electrical connections (battery, PV, AC input/output) for tightness and signs of corrosion. Loose connections can lead to overheating and poor performance.
- Battery Health: Monitor your battery bank's health and charge levels. Ensure batteries are maintained according to their manufacturer's guidelines.
- Environmental Conditions: Ensure the inverter operates within its specified temperature range (-10°C to 55°C) and in a dry environment.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure optimal performance and access to new features.
8. Troubleshooting
If you encounter issues with your PowMr Hybrid Solar Inverter, refer to the following basic troubleshooting steps:
- No Power/No Display:
- Check if the Power On/Off Switch (6) is in the 'ON' position.
- Verify battery connections and ensure the battery voltage is sufficient (above 20.5VDC).
- Check for any tripped circuit breakers or blown fuses in the battery or AC input lines.
- Fault Indicator (4) is On:
- An illuminated Fault Indicator suggests an error. Check the LCD display for specific error codes or messages.
- Common faults include Overload, Over-temperature, Short-circuit, Low/High DC Voltage. Address the underlying cause (e.g., reduce load, improve ventilation, check battery voltage).
- No AC Output:
- Ensure the inverter is in 'Line Mode' or 'Battery Mode' and not in a fault state.
- Check AC output connections to your loads.
- Verify that the battery is adequately charged if operating in battery mode.
- Battery Not Charging:
- Check if the Charging Indicator (3) is active.
- From Solar: Ensure PV panels are connected correctly, receiving sunlight, and the PV array voltage is within the MPPT range.
- From AC: Verify AC input connection and ensure the utility grid or generator is supplying power. Check AC input voltage.
- Review the AC/Solar Charger priority setting on the LCD.
For persistent issues, consult the full user manual or contact customer support.
9. User Tips
- Optimal PV Sizing: To maximize solar charging efficiency, ensure your PV array's total power and voltage are well-matched to the inverter's MPPT specifications. Aim for a PV voltage within the 30-400VDC range for best performance.
- Battery Compatibility: While the inverter supports various battery types, always configure the correct battery type and charging parameters via the LCD settings to prevent damage and optimize battery lifespan.
- Ventilation is Key: Proper ventilation is crucial for the inverter's longevity. Ensure it's installed in a location with good airflow and keep the cooling fan vents clear of obstructions.
- Load Management: Avoid consistently running loads close to the inverter's maximum capacity. This can reduce efficiency and increase wear on components. Distribute loads where possible.
- Remote Monitoring: If you have the WIFI/GPRS module, utilize its remote monitoring capabilities to keep track of your system's performance and health from anywhere.
10. Warranty & Support
This PowMr Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact PowMr customer service through their official channels. When contacting support, please have your product model number (POW-HVM3.2H-24V-N) and purchase details ready.