This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your VEVOR Portable Refrigerant Recovery Machine. This device is designed for recovering refrigerants from various AC and HVAC systems, including automotive, air conditioning, and refrigeration units. Please read this manual thoroughly before use to ensure proper function and safety.

2. Safety Information

Always prioritize safety when operating refrigerant recovery equipment. Failure to follow safety guidelines can result in injury or equipment damage.

  • Ensure the machine is connected to a grounded power source (120V ~ 60Hz).
  • Operate in a well-ventilated area to prevent accumulation of refrigerant vapors.
  • Wear appropriate personal protective equipment (PPE), including safety glasses and gloves.
  • Avoid contact with liquid refrigerant, as it can cause frostbite.
  • The machine features high-pressure protection with an automatic shutoff at or above 38.6 bar / 558 psi to prevent overpressure damage.
  • Overcurrent protection is also integrated for enhanced safety.
  • Do not use the machine if any parts are damaged or missing.
  • Refer to the official user manual PDF for detailed safety warnings and precautions: User Manual (PDF).
Refrigerant Recovery Machine with pressure gauge showing automatic shutoff at 558psi and overcurrent protection icon.
Figure 2.1: Safety Features - Automatic Shutoff and Overcurrent Protection.

3. Product Overview

The VEVOR Portable Refrigerant Recovery Machine is a compact and efficient tool designed for professional refrigerant recycling. It features a robust motor, high-efficiency condenser, and user-friendly controls.

3.1. Key Features

  • High-Efficiency Recovery: Swiftly recovers vapor and liquid refrigerants with a powerful brush motor.
  • Portable & Compact: Lightweight design (approx. 29.5 lbs / 13.4 kg) with an ergonomic handle for easy transport.
  • Broad Refrigerant Compatibility: Capable of recovering R134A, R22, R12, R410A, R404A, R502, and other refrigerants from Categories III, IV, and V.
  • Adjustable Recovery Speed: A single knob controls three modes: Recover Slow, Recover Fast, and Purge.
  • Self-Purge Function: Automatically discharges leftover refrigerant into the recovery tank, preventing machine damage and ensuring purity.
  • Double Filtration System: Includes a reusable filter net and an advanced dryer to isolate impurities and water, preventing oxidation and rust.
  • Rapid Cooling: Built-in condenser and fan ensure efficient heat dissipation for stable operation.
Person carrying the VEVOR refrigerant recovery machine, highlighting its portable and compact design and 29.5 lbs weight.
Figure 3.1: Portable and Compact Design.
Three VEVOR recovery machines shown with labels for Car (R134A), Air Conditioner (R22, R410A), and Refrigerator (R12, R404A, R502) refrigerants.
Figure 3.2: Broad Refrigerant Compatibility.

4. Specifications

The VEVOR Refrigerant Recovery Machine is available in two power options:

4.1. 1HP Model Specifications

Specifications for the 1HP VEVOR Refrigerant Recovery Machine, including net weight, power, voltage, high pressure protection, operating temperature, max liquid recovery rate, rotation speed, air inlet/exhaust interface, and dimensions.
Figure 4.1: 1HP Model Specifications.
Parameter Value (1HP Model)
Net Weight 30.9 lbs / 14 kg
Power 1 HP
Voltage 120V ~ 60Hz
High Pressure Protection 558 PSI / 38.6 Bar
Operating Temperature 32°F-104°F / 0-40°C
Max. Liquid Recovery Rate 7.7 lb / min
Rotation Speed 1750 RPM
Air Inlet Interface 1/4" SAE
Exhaust Interface 1/4" SAE
Dimensions (L x W x H) 15.7 in x 9.8 in x 14.2 in / 40 cm x 25 cm x 36 cm

4.2. 3/4 HP Model Specifications

Specifications for the 3/4 HP VEVOR Refrigerant Recovery Machine, including net weight, power, voltage, high pressure protection, operating temperature, max liquid recovery rate, rotation speed, air inlet/exhaust interface, and dimensions.
Figure 4.2: 3/4 HP Model Specifications.
Parameter Value (3/4 HP Model)
Net Weight 29.5 lbs / 13.4 kg
Power 3/4 HP
Voltage 120V ~ 60Hz
High Pressure Protection 558 PSI / 38.6 Bar
Operating Temperature 32°F-104°F / 0-40°C
Max. Liquid Recovery Rate 4.85 lb / min
Rotation Speed 1450 RPM
Air Inlet Interface 1/4" SAE
Exhaust Interface 1/4" SAE
Dimensions (L x W x H) 15.7 in x 9.8 in x 14.2 in / 40 cm x 25 cm x 36 cm
Table showing liquid recovery rates for Category III (3.52 lb/min), Category IV (3.97 lb/min), and Category V (4.85 lb/min) refrigerants.
Figure 4.3: Liquid Recovery Rates by Refrigerant Category.

5. Setup

5.1. Unpacking and Inspection

  • Carefully remove the recovery machine from its packaging.
  • Inspect the machine for any signs of damage during transit.
  • Ensure all components listed in the packing list are present.

5.2. Quick Installation and Connection

Follow these steps for quick installation and connection:

  1. Place the recovery machine on a stable, level surface in a well-ventilated area.
  2. Connect the appropriate hoses from your AC/HVAC system to the 'IN' port of the recovery machine.
  3. Connect a hose from the 'OUT' port of the recovery machine to your recovery tank.
  4. Ensure all connections are tight to prevent leaks.
  5. Connect the power cord to a suitable 120V ~ 60Hz grounded outlet.
Diagram showing the VEVOR recovery machine connected to an AC unit and a recovery tank via hoses and a manifold gauge. Labeled 'STEP 1 QUICK INSTALLATION AND CONNECTION'.
Figure 5.1: Quick Installation and Connection Diagram.

6. Operating Instructions

6.1. Control Knob Functions

The main control knob on the front panel allows you to select different operating modes:

  • OFF: Turns the machine off.
  • RECOVER SLOW: Initiates refrigerant recovery at a slower rate.
  • RECOVER FAST: Initiates refrigerant recovery at a faster rate.
  • PURGE: Activates the self-cleaning function to drain air and clean pipes.
Close-up of the control knob on the VEVOR recovery machine, showing positions for 'RECOVER SLOW', 'OFF', 'RECOVER FAST', and 'PURGE'. A hand is shown adjusting the knob.
Figure 6.1: Control Knob for Speed and Purge Modes.

6.2. Draining Air (Pre-Operation)

Before starting recovery, it is crucial to drain air from the system to ensure safety and efficiency:

  1. Ensure all hoses are correctly connected as per the setup instructions.
  2. Rotate the control knob to the PURGE position.
  3. The machine will automatically discharge air from the system. Monitor the pressure gauges.
  4. Once air is drained, proceed to the recovery process.
Close-up of the VEVOR recovery machine's control panel, with the knob rotated to 'PURGE' and an arrow indicating air draining. Labeled 'STEP 2 DRAIN AIR TO ENSURE SAFETY'.
Figure 6.2: Draining Air using the Purge Function.

6.3. Refrigerant Recovery Process

After draining air, proceed with refrigerant recovery:

  1. With the machine powered on and connections secure, select either RECOVER SLOW or RECOVER FAST using the control knob.
  2. Monitor the pressure gauges on the machine to observe real-time pressure dynamics.
  3. The machine will automatically stop recovery if the pressure reaches or exceeds 558 PSI (38.6 Bar) due to high-pressure protection.
  4. Once recovery is complete, turn the knob to OFF.

7. Maintenance

7.1. One-Touch Automatic Pipe Cleaning (Self-Purge)

To maintain the machine's longevity and prevent cross-contamination, perform a self-purge after each use:

  1. Ensure the recovery process is complete and the machine is connected to an empty recovery tank.
  2. Rotate the control knob to the PURGE position.
  3. This function safely discharges any leftover refrigerant into the recovery tank, preventing plugging, expansion, or damage to internal parts.
  4. Allow the purge cycle to complete before disconnecting hoses.
Close-up of the VEVOR recovery machine's control panel, with the knob rotated to 'PURGE' and an arrow indicating flow for pipe cleaning. Labeled 'STEP 4 ONE-TOUCH AUTOMATIC PIPE CLEANING'.
Figure 7.1: One-Touch Automatic Pipe Cleaning.

7.2. Filter Screen and Dryer Maintenance

The machine is equipped with a reusable and easy-to-clean filter screen and an advanced dryer to ensure refrigerant purity.

  • Regularly inspect and clean the filter screen to prevent impurities from entering the intake port.
  • The advanced dryer helps remove moisture from the refrigerant, preventing oxidation and rust.
  • It is advised to regularly replace the dryer to maintain the purity of the recovery process.
Diagram showing the internal filter net and advanced dryer components designed to isolate impurities and water.
Figure 7.2: Double Barriers for Impurity and Water Isolation.

7.3. General Care

  • Keep the machine clean and free of dust and debris.
  • Store the machine in a dry, cool place when not in use.
  • Avoid exposing the machine to extreme temperatures or direct sunlight for prolonged periods.

8. Troubleshooting

This section provides solutions to common issues you might encounter. For more complex problems, refer to the full user manual PDF or contact customer support.

Problem Possible Cause Solution
Machine does not power on No power supply; Power switch off; Circuit breaker tripped Check power connection; Ensure power switch is ON; Reset circuit breaker if tripped.
Slow recovery rate Clogged filter screen; Low refrigerant pressure; Incorrect mode selected Clean or replace filter screen; Ensure adequate refrigerant in system; Select 'RECOVER FAST' mode.
Machine stops unexpectedly High-pressure protection activated; Overcurrent protection activated Check system pressure and connections; Allow machine to cool down if overheated.
Refrigerant not pure after recovery Dirty filter screen; Worn-out dryer; Incomplete purge cycle Clean filter screen; Replace dryer; Ensure proper self-purge after each use.

9. User Tips

  • Always ensure your recovery tank is empty and properly evacuated before starting a new recovery process to maximize efficiency and prevent contamination.
  • For optimal performance and to prevent machine damage, consistently use the 'PURGE' function after each recovery operation.
  • Keep an eye on the pressure gauges during operation; they provide crucial real-time feedback on the recovery process and system status.

10. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the official VEVOR documentation or contact the seller directly. The comprehensive user manual in PDF format can be accessed here: User Manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?