1. Introduction
The MESTEK DM100 and DM100C are advanced digital multimeters designed for professional electricians and DIY enthusiasts. Featuring 10000 counts and a smart dual-core processor, these multimeters offer high accuracy, fast measurement, and a range of functions including AC/DC voltage, current, resistance, capacitance, frequency, and more. The DM100C model additionally includes a temperature probe and auto-ranging capabilities.


2. Package Contents
Upon opening your MESTEK Digital Multimeter package, please ensure all the following items are present:
- MESTEK DM100C Multimeter (or DM100, depending on model purchased) x 1
- 10A Original Test Leads x 1 pair
- Packing Box x 1
- Instruction Manual x 1

3. Product Features
The MESTEK DM100/DM100C series offers a robust set of features for accurate and safe electrical testing:
- Display Count: 10000 counts with digital dual display and analog bar.
- Operating Mode: Auto Range (DM100C) or Manual Range (DM100).
- True RMS: 1KHz real effective measurement for accurate AC readings.
- Non-Contact Voltage (NCV): Safe detection of AC voltage without direct contact, with audial and visual alarms.
- LIVE Fire Line Identification: Single-table pen recognition for live wire detection.
- Variable Frequency Voltage (V.F.C): Function for measuring variable frequency voltage.
- Fuse Alarm: Alerts the user if the fuse is blown, indicating the need for replacement.
- Wrong Insertion Alarm: Provides an alarm if test leads are incorrectly inserted.
- Data Retention: 'HOLD' function to freeze the current reading on the display.
- Flashlight: Built-in LED lighting for use in dark environments.
- Automatic Shut-down: Powers off after 15 minutes of inactivity to save battery.
- Anti-burn Protection: Full-range gear protection for voltages up to 250V (DM100C).
- Soft Rubber Sleeve: Anti-drop design for enhanced durability.
- Temperature Measurement: DM100C includes a temperature probe for -20°C to 1000°C (-4°F to 1832°F).
- Ambient Temperature & Humidity: Measures ambient conditions (DM100: 0°C-60°C, 0-100% humidity; DM100C: 0°C-60°C).
- Battery Measurement: 0-1.5V / 0-9V.
- Diode Test: 0.15V~3V.
- Continuity Test: Buzzer detection for resistance less than 15 Ohm.

4. Safety Information
Always adhere to safety precautions when using the multimeter to prevent electric shock or damage to the device.
- Ensure the correct function and range are selected before making measurements.
- Do not exceed the maximum input values for any range.
- Always disconnect the test leads from the circuit before changing functions or ranges.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
- Inspect test leads for damage before use.
- Do not operate the meter if it appears damaged or if the case is open.
- Replace the battery when the low battery indicator appears.
- The DM100C model features anti-burn protection for voltages up to 250V.
5. Setup and Operation
5.1. Battery Installation
The multimeter requires 2 AA batteries (not included). To install:
- Ensure the multimeter is turned off.
- Locate the battery compartment on the back of the device.
- Unscrew the battery cover and remove it.
- Insert 2 AA batteries, observing the correct polarity (+/-).
- Replace the battery cover and secure it with the screw.
5.2. Connecting Test Leads
Always connect the black test lead to the 'COM' jack. Connect the red test lead to the appropriate jack based on the measurement function:
- For Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, Temperature (DM100C), NCV, LIVE: Connect the red lead to the 'VΩHz' jack.
- For Current (mA/µA): Connect the red lead to the 'mAµA' jack.
- For High Current (10A): Connect the red lead to the '10A' jack.
5.3. Panel Introduction

Key components:
- Flashlight: Top left.
- Indicator Light: Top center (for NCV, LIVE).
- Reverse Display AV Screen: Main display.
- Data Retention (HOLD): Button to freeze readings.
- Switch/Select (SEL): Button to cycle through functions within a dial position.
- Lighting Switch: Button to turn on/off the flashlight.
- Variable Frequency Voltage (V.F.C): Button to activate V.F.C mode.
- Soft Rubber Case: Provides anti-drop protection.
- Gear Wheel: Rotary switch to select measurement functions.
- Current Input Jacks (mAµA, 10A): For current measurements.
- Measurement Input Jack (VΩHz): For voltage, resistance, capacitance, frequency, etc.
- Common Port (COM): For the black test lead.
5.4. Basic Measurement Functions
Turn the gear wheel to the desired function. Use the 'SEL' button to switch between sub-functions (e.g., AC/DC voltage, diode/continuity).
5.4.1. AC/DC Voltage and Current Measurement
The multimeter can measure both AC and DC voltage and current. The video demonstrates switching between AC and DC modes for voltage measurement.
Video 1: Demonstration of AC+DC function, voltage, resistance, capacitance, error insertion, fuse alarm, LIVE firewire identification, and buzzer tests.
5.4.2. Resistance Measurement
Turn the gear wheel to the Ω position. Connect the test leads across the component to measure resistance. The display will show 'OL' if the resistance is out of range or the circuit is open.
5.4.3. Capacitance Measurement
Turn the gear wheel to the capacitance symbol (nF/µF/mF). Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.

5.4.4. Frequency Measurement
Turn the gear wheel to the Hz position. Connect the test leads to the circuit to measure frequency.

5.4.5. Non-Contact Voltage (NCV) Detection
Turn the gear wheel to the NCV position. Bring the top of the multimeter close to an AC voltage source. The indicator light will flash and the buzzer will sound, with the display showing '---H' for high pressure or '---L' for low pressure.


5.4.6. LIVE Fire Line Identification
Turn the gear wheel to the LIVE position. Insert the red test lead into the live wire. The display will show 'LIVE' and the indicator light will illuminate.

5.4.7. Variable Frequency Voltage (V.F.C) Measurement
Turn the range dial to the auto range voltage position, press 'SEL' to enter the AC voltage range, and then press the blue 'V.F.C' button to turn on the variable voltage measurement mode.

6. Maintenance
6.1. Cleaning
Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents.
6.2. Fuse Replacement
The multimeter is equipped with fast-dissolving professional ceramic fuse tubes in the 600mA/10A gear. If a fuse blows, the display will show 'FUSE' and an alarm will sound. To replace:
- Turn off the multimeter and disconnect all test leads.
- Unscrew the back cover and carefully open the casing.
- Locate the blown fuse (typically near the current input jacks).
- Replace with a fuse of the same type and rating (e.g., 600mA/10A).
- Close the casing and secure the screws.

6.3. Anti-Drop Protection
The multimeter features a soft rubber sleeve designed to protect it from drops and impacts, enhancing its durability in demanding work environments.

7. Troubleshooting
- No Display/Low Battery: Check battery installation and replace batteries if the low battery indicator is on or the display is dim.
- 'OL' on Display: Indicates an over-range condition or an open circuit. Ensure the correct range is selected and the circuit is complete.
- 'LEAD' on Display / Buzzer Alarm: Indicates incorrect test lead insertion for the selected function. Re-insert leads into the correct jacks.
- 'FUSE' on Display / Buzzer Alarm: Indicates a blown fuse. Refer to Section 6.2 for fuse replacement.
- Inaccurate Readings: Ensure test leads are properly connected, the correct function/range is selected, and the batteries are not low.
8. Specifications
| Feature | DM100 | DM100C |
|---|---|---|
| Model Number | DM100 | DM100C |
| Display Count | 10000 count | 10000 count |
| Operating Mode | Manual Range | Auto and Manual Range |
| DC Voltage | 0~999.9mV/9.999V/99.99V/999.9V | 0~999.9mV/9.999V/99.99V/999.9V |
| AC Voltage | 0~999.9mV/9.999V/99.99V/999.9V | 0~999.9mV/9.999V/99.99V/999.9V |
| DC Current | 0~99.99mA/600mA/10.00A | 0~99.99mA/600mA/10.00A |
| AC Current | 0~99.99mA/600mA/10.00A | 0~99.99mA/600mA/10.00A |
| Measuring Resistance Range | 0~999.9ohm/9.999Kohm/99.99Kohm/999.9Kohm/9.999Mohm/99.99Mohm | 0~999.9ohm/9.999Kohm/99.99Kohm/999.9Kohm/9.999Mohm/99.99Mohm |
| Measuring Capacitance Range | 0~9.999nF/99.99nF/999.9nF/9.999uF/99.99uF/999.9uF/9.999mF | 0~9.999nF/99.99nF/999.9nF/9.999uF/99.99uF/999.9uF/9.999mF |
| Frequency | 0~9.999MHz | 0~9.999MHz |
| Temperature Probe Measure | No | Have (-20°C~1000°C / -4°F~1832°F) |
| Operating Temperature | 0 - 40 ℃ | 0 - 40 ℃ |
| Environment Humidity | 20~95% | 20~95% |
| Battery Measurement | 0~1.5V/0~9V | 0~1.5V/0~9V |
| Buzzer Detection | 2kHz/2.7kHz/3V | 2kHz/2.7kHz/3V |
| True RMS | 1kHz | 1kHz |
| High Speed Sampling | sampling rate 10 times/second | sampling rate 10 times/second |
| Wrong Insertion Alarm | LUSE and buzzer alarm | LUSE and buzzer alarm |
| Fuse Alarm | 600mA/10A | 600mA/10A |
| Data Retention | Yes | Yes |
| Flashlight | Yes | Yes |
| Automatic Shut-down | 15 minutes without operation | 15 minutes without operation |
| NCV | non-contact AC voltage detection | non-contact AC voltage detection |
| Input Resistance | 10Mohm | 10Mohm |
| Under Voltage Prompt | less than 2.4V | less than 2.4V |
| On-off Beep | 0~100Ohm resistance less than 15Ohm | 0~100Ohm resistance less than 15Ohm |
| Diode | 0.15V~3V | 0.15V~3V |
| Overload Protection | less than 250v | less than 250v |
| LIVE | fire line identification | fire line identification |
| Dimensions | 185*85*40 mm | 185*85*40 mm |
| Weight | About 500g | About 500g |
| Security Level | CAT IV 600V/CATIII 1000V | CAT IV 600V/CATIII 1000V |

9. User Tips
- For accurate temperature readings with the DM100C, ensure the temperature probe is correctly inserted and in good contact with the surface being measured.
- When using the NCV function, move the meter slowly along the wire or outlet to pinpoint the live source.
- Always double-check the selected function and range before connecting the test leads to avoid damaging the meter or the circuit.
- The flashlight feature is very useful in dimly lit areas, making it easier to see connection points.
10. Warranty and Support