MESTEK DM100/DM100C

Contents

MESTEK DM100/DM100C Digital Multimeter User Manual

Your essential guide to safe and effective electrical measurements.

1. Introduction

The MESTEK DM100 and DM100C are advanced digital multimeters designed for professional electricians and DIY enthusiasts. Featuring 10000 counts and a smart dual-core processor, these multimeters offer high accuracy, fast measurement, and a range of functions including AC/DC voltage, current, resistance, capacitance, frequency, and more. The DM100C model additionally includes a temperature probe and auto-ranging capabilities.

MESTEK DM100 Series Digital Multimeters
Figure 1: MESTEK DM100 Series Digital Multimeters (DM100C on left, DM100 on right) with digital dual display and analog strip.
MESTEK DM100C Multimeter with function icons
Figure 2: MESTEK DM100C highlighting automatic/manual ranging and various functions like Voltage, Current, Resistance, Capacitance, Live, NCV, Diode, and Continuity.

2. Package Contents

Upon opening your MESTEK Digital Multimeter package, please ensure all the following items are present:

  • MESTEK DM100C Multimeter (or DM100, depending on model purchased) x 1
  • 10A Original Test Leads x 1 pair
  • Packing Box x 1
  • Instruction Manual x 1
Package contents of MESTEK DM100C multimeter
Figure 3: Contents of the MESTEK DM100C package, including the multimeter and test leads.

3. Product Features

The MESTEK DM100/DM100C series offers a robust set of features for accurate and safe electrical testing:

  • Display Count: 10000 counts with digital dual display and analog bar.
  • Operating Mode: Auto Range (DM100C) or Manual Range (DM100).
  • True RMS: 1KHz real effective measurement for accurate AC readings.
  • Non-Contact Voltage (NCV): Safe detection of AC voltage without direct contact, with audial and visual alarms.
  • LIVE Fire Line Identification: Single-table pen recognition for live wire detection.
  • Variable Frequency Voltage (V.F.C): Function for measuring variable frequency voltage.
  • Fuse Alarm: Alerts the user if the fuse is blown, indicating the need for replacement.
  • Wrong Insertion Alarm: Provides an alarm if test leads are incorrectly inserted.
  • Data Retention: 'HOLD' function to freeze the current reading on the display.
  • Flashlight: Built-in LED lighting for use in dark environments.
  • Automatic Shut-down: Powers off after 15 minutes of inactivity to save battery.
  • Anti-burn Protection: Full-range gear protection for voltages up to 250V (DM100C).
  • Soft Rubber Sleeve: Anti-drop design for enhanced durability.
  • Temperature Measurement: DM100C includes a temperature probe for -20°C to 1000°C (-4°F to 1832°F).
  • Ambient Temperature & Humidity: Measures ambient conditions (DM100: 0°C-60°C, 0-100% humidity; DM100C: 0°C-60°C).
  • Battery Measurement: 0-1.5V / 0-9V.
  • Diode Test: 0.15V~3V.
  • Continuity Test: Buzzer detection for resistance less than 15 Ohm.
List of MESTEK Multimeter features
Figure 4: Key features of the MESTEK DM100 series multimeters.

4. Safety Information

Always adhere to safety precautions when using the multimeter to prevent electric shock or damage to the device.

  • Ensure the correct function and range are selected before making measurements.
  • Do not exceed the maximum input values for any range.
  • Always disconnect the test leads from the circuit before changing functions or ranges.
  • Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
  • Inspect test leads for damage before use.
  • Do not operate the meter if it appears damaged or if the case is open.
  • Replace the battery when the low battery indicator appears.
  • The DM100C model features anti-burn protection for voltages up to 250V.

5. Setup and Operation

5.1. Battery Installation

The multimeter requires 2 AA batteries (not included). To install:

  1. Ensure the multimeter is turned off.
  2. Locate the battery compartment on the back of the device.
  3. Unscrew the battery cover and remove it.
  4. Insert 2 AA batteries, observing the correct polarity (+/-).
  5. Replace the battery cover and secure it with the screw.

5.2. Connecting Test Leads

Always connect the black test lead to the 'COM' jack. Connect the red test lead to the appropriate jack based on the measurement function:

  • For Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, Temperature (DM100C), NCV, LIVE: Connect the red lead to the 'VΩHz' jack.
  • For Current (mA/µA): Connect the red lead to the 'mAµA' jack.
  • For High Current (10A): Connect the red lead to the '10A' jack.

5.3. Panel Introduction

Labeled diagram of MESTEK DM100C multimeter panel
Figure 5: Front panel layout of the MESTEK DM100C multimeter.

Key components:

  • Flashlight: Top left.
  • Indicator Light: Top center (for NCV, LIVE).
  • Reverse Display AV Screen: Main display.
  • Data Retention (HOLD): Button to freeze readings.
  • Switch/Select (SEL): Button to cycle through functions within a dial position.
  • Lighting Switch: Button to turn on/off the flashlight.
  • Variable Frequency Voltage (V.F.C): Button to activate V.F.C mode.
  • Soft Rubber Case: Provides anti-drop protection.
  • Gear Wheel: Rotary switch to select measurement functions.
  • Current Input Jacks (mAµA, 10A): For current measurements.
  • Measurement Input Jack (VΩHz): For voltage, resistance, capacitance, frequency, etc.
  • Common Port (COM): For the black test lead.

5.4. Basic Measurement Functions

Turn the gear wheel to the desired function. Use the 'SEL' button to switch between sub-functions (e.g., AC/DC voltage, diode/continuity).

5.4.1. AC/DC Voltage and Current Measurement

The multimeter can measure both AC and DC voltage and current. The video demonstrates switching between AC and DC modes for voltage measurement.

Video 1: Demonstration of AC+DC function, voltage, resistance, capacitance, error insertion, fuse alarm, LIVE firewire identification, and buzzer tests.

5.4.2. Resistance Measurement

Turn the gear wheel to the Ω position. Connect the test leads across the component to measure resistance. The display will show 'OL' if the resistance is out of range or the circuit is open.

5.4.3. Capacitance Measurement

Turn the gear wheel to the capacitance symbol (nF/µF/mF). Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.

MESTEK DM100C measuring capacitance
Figure 6: DM100C measuring capacitance, showing a reading of 39.97mF.

5.4.4. Frequency Measurement

Turn the gear wheel to the Hz position. Connect the test leads to the circuit to measure frequency.

MESTEK DM100C measuring frequency
Figure 7: DM100C measuring frequency, showing a 999.9Hz output from a 5V/1KHz source.

5.4.5. Non-Contact Voltage (NCV) Detection

Turn the gear wheel to the NCV position. Bring the top of the multimeter close to an AC voltage source. The indicator light will flash and the buzzer will sound, with the display showing '---H' for high pressure or '---L' for low pressure.

MESTEK DM100 performing NCV test
Figure 8: DM100 performing a Non-Contact Voltage (NCV) test near a power outlet.
MESTEK DM100C NCV detection display
Figure 9: DM100C display during NCV detection, showing '---H' for high pressure.

5.4.6. LIVE Fire Line Identification

Turn the gear wheel to the LIVE position. Insert the red test lead into the live wire. The display will show 'LIVE' and the indicator light will illuminate.

MESTEK DM100C performing LIVE fire line identification
Figure 10: DM100C performing LIVE fire line identification in an electrical panel.

5.4.7. Variable Frequency Voltage (V.F.C) Measurement

Turn the range dial to the auto range voltage position, press 'SEL' to enter the AC voltage range, and then press the blue 'V.F.C' button to turn on the variable voltage measurement mode.

MESTEK DM100C V.F.C measurement
Figure 11: DM100C displaying a V.F.C measurement.

6. Maintenance

6.1. Cleaning

Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents.

6.2. Fuse Replacement

The multimeter is equipped with fast-dissolving professional ceramic fuse tubes in the 600mA/10A gear. If a fuse blows, the display will show 'FUSE' and an alarm will sound. To replace:

  1. Turn off the multimeter and disconnect all test leads.
  2. Unscrew the back cover and carefully open the casing.
  3. Locate the blown fuse (typically near the current input jacks).
  4. Replace with a fuse of the same type and rating (e.g., 600mA/10A).
  5. Close the casing and secure the screws.
MESTEK DM100 fuse alarm and internal view
Figure 12: DM100 showing 'FUSE' alarm and an internal view of the fuse location.

6.3. Anti-Drop Protection

The multimeter features a soft rubber sleeve designed to protect it from drops and impacts, enhancing its durability in demanding work environments.

MESTEK DM100C with soft rubber case
Figure 13: DM100C encased in its protective soft rubber sleeve.

7. Troubleshooting

  • No Display/Low Battery: Check battery installation and replace batteries if the low battery indicator is on or the display is dim.
  • 'OL' on Display: Indicates an over-range condition or an open circuit. Ensure the correct range is selected and the circuit is complete.
  • 'LEAD' on Display / Buzzer Alarm: Indicates incorrect test lead insertion for the selected function. Re-insert leads into the correct jacks.
  • 'FUSE' on Display / Buzzer Alarm: Indicates a blown fuse. Refer to Section 6.2 for fuse replacement.
  • Inaccurate Readings: Ensure test leads are properly connected, the correct function/range is selected, and the batteries are not low.

8. Specifications

FeatureDM100DM100C
Model NumberDM100DM100C
Display Count10000 count10000 count
Operating ModeManual RangeAuto and Manual Range
DC Voltage0~999.9mV/9.999V/99.99V/999.9V0~999.9mV/9.999V/99.99V/999.9V
AC Voltage0~999.9mV/9.999V/99.99V/999.9V0~999.9mV/9.999V/99.99V/999.9V
DC Current0~99.99mA/600mA/10.00A0~99.99mA/600mA/10.00A
AC Current0~99.99mA/600mA/10.00A0~99.99mA/600mA/10.00A
Measuring Resistance Range0~999.9ohm/9.999Kohm/99.99Kohm/999.9Kohm/9.999Mohm/99.99Mohm0~999.9ohm/9.999Kohm/99.99Kohm/999.9Kohm/9.999Mohm/99.99Mohm
Measuring Capacitance Range0~9.999nF/99.99nF/999.9nF/9.999uF/99.99uF/999.9uF/9.999mF0~9.999nF/99.99nF/999.9nF/9.999uF/99.99uF/999.9uF/9.999mF
Frequency0~9.999MHz0~9.999MHz
Temperature Probe MeasureNoHave (-20°C~1000°C / -4°F~1832°F)
Operating Temperature0 - 40 ℃0 - 40 ℃
Environment Humidity20~95%20~95%
Battery Measurement0~1.5V/0~9V0~1.5V/0~9V
Buzzer Detection2kHz/2.7kHz/3V2kHz/2.7kHz/3V
True RMS1kHz1kHz
High Speed Samplingsampling rate 10 times/secondsampling rate 10 times/second
Wrong Insertion AlarmLUSE and buzzer alarmLUSE and buzzer alarm
Fuse Alarm600mA/10A600mA/10A
Data RetentionYesYes
FlashlightYesYes
Automatic Shut-down15 minutes without operation15 minutes without operation
NCVnon-contact AC voltage detectionnon-contact AC voltage detection
Input Resistance10Mohm10Mohm
Under Voltage Promptless than 2.4Vless than 2.4V
On-off Beep0~100Ohm resistance less than 15Ohm0~100Ohm resistance less than 15Ohm
Diode0.15V~3V0.15V~3V
Overload Protectionless than 250vless than 250v
LIVEfire line identificationfire line identification
Dimensions185*85*40 mm185*85*40 mm
WeightAbout 500gAbout 500g
Security LevelCAT IV 600V/CATIII 1000VCAT IV 600V/CATIII 1000V
Comparison of DM100 and DM100C specifications
Figure 14: Detailed comparison of DM100 and DM100C specifications.

9. User Tips

  • For accurate temperature readings with the DM100C, ensure the temperature probe is correctly inserted and in good contact with the surface being measured.
  • When using the NCV function, move the meter slowly along the wire or outlet to pinpoint the live source.
  • Always double-check the selected function and range before connecting the test leads to avoid damaging the meter or the circuit.
  • The flashlight feature is very useful in dimly lit areas, making it easier to see connection points.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official MESTEK website. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.