HLTNC 130ASG-M14715

Contents

HLTNC 2.3kW EtherCAT Servo Motor Kit User Manual

Model: 130ASG-M14715 with ECX-30EL23 Driver

1. Introduction

1.1. Overview

The ECX series servo is a bus servo drive that integrates bus communication functionality with a high-performance AC servo drive. Utilizing the EtherCAT bus communication interface and real-time transmission technology at 100 Mb/s, it enables precise control of the servo system. The drive features rich input and output interfaces and supports various operation modes including CSP (Cyclic Synchronous Position), CSV (Cyclic Synchronous Velocity), CST (Cyclic Synchronous Torque), PP (Profile Position), PV (Profile Velocity), PT (Profile Torque), and HM (Homing). Compared to traditional pulse servo drives, this system is particularly well-suited for long-distance and multi-axis linkage applications, significantly reducing wiring complexity and enhancing operational reliability.

1.2. Features

  • Working Voltage: AC220V ± 10%, single-phase or three-phase, 50/60Hz.
  • Communication Protocol: Supports EtherCAT, with automatic address allocation via the main station.
  • Input Functions: 8 single-terminal common isolation input functions, maximum input frequency of 10 KHz, input voltage of 24 V.
  • Output Functions: 6 optical coupling isolation outputs, maximum output capacity of 50 mA, and maximum voltage of 30 Vdc.

1.3. Application Fields

This servo motor kit is ideal for small and medium-sized automation equipment and instruments requiring multi-axis linkage control. Common applications include:

  • 3D Printers
  • CNC Machines
  • Textile Machinery
  • Cutting Machines
  • Manipulators
  • Packaging Machinery
Application scenarios for HLTNC servo motor kit
Figure 1.1: Application scenarios for the HLTNC Servo Motor Kit, including 3D printers, CNC machines, textile machines, and cutting machines.

2. Safety Precautions

Before product storage, installation, wiring, operation, inspection, or repair, users must be familiar with and comply with the following guidelines to ensure safe use of the product.

Danger: Wrong Operation Can Cause Personal Injury

  • Use Environment: Do not expose products to water, corrosive substances, or combustible gases to prevent electric shock or fire. Avoid direct sunlight, dust, salt, metal powder, water, oil, or medicine drops.
  • Wiring:
    • Reliably ground the grounding terminal. Poor grounding can cause electric shock or fire.
    • Do not connect the 220V drive power supply to a 380V power supply; this will cause equipment damage, electric shock, or fire.
    • Connect the motor's U, V, and W output terminals to the three-phase power supply, ensuring they correspond one-to-one with the motor's U, V, and W terminals. Incorrect connection can cause the motor to malfunction, leading to casualties or fire.
    • Tighten power supply and motor output terminals securely to prevent fire.
    • Refer to the wiring instructions in this manual to prevent fire or other hazards.
  • Operation:
    • Never contact rotating parts when the motor is running to prevent casualties.
    • Do not touch the driver or motor when the equipment is running to prevent electric shock or burns.
    • Do not move connecting cables when the equipment is running to prevent personnel injury or equipment damage.
  • Maintenance and Inspection:
    • Do not contact the internal components of the driver or motor to prevent electric shock.
    • Do not remove the drive panel when the power supply is active to prevent electric shock.
    • Avoid contact with wiring terminals for at least 5 minutes after power-off to prevent electric shock from residual high voltage.
    • Do not change wiring or remove the servo motor when the power supply is active to prevent electric shock.

Attention: Incorrect Operation May Damage Equipment

  • Operation:
    • Ensure the mechanical equipment's parameters are set correctly before operation to prevent loss of control or failure.
    • Confirm that the emergency stop switch is accessible and functional before starting operation.
    • Test the servo motor with no load before connecting the actual load to avoid unnecessary damage.
    • Avoid frequent power cycling (turning on/off) of the power supply to prevent overheating of the drive.
  • Scope of Use: These products are intended for general industrial use and should not be used in applications where direct danger to personal safety is involved.

3. Product Components

The HLTNC 2.3kW EtherCAT Servo Motor Kit typically includes the following main components:

  • 1x 2.3KW AC Servo Motor (Model: ECX-F5CH230S-M2XN*K)
  • 1x AC Servo Drive (Model: ECX-30EL23, with included accessories)
  • 1x ECX130-10E Code Line (3 meters)
  • 1x ECX130-4P10 Power Line (3 meters)
HLTNC 2.3kW EtherCAT Servo Motor Kit components
Figure 3.1: Main components of the HLTNC 2.3kW EtherCAT Servo Motor Kit.

4. Specifications

4.1. General Product Specifications

Attribute Value
Brand NameHLTNC
Model Number130ASG-M14715
TypeServo Motor
OriginMainland China
CertificationRoHS, NONE, CE, CCC
AC Voltage220V
Frequency50HZ/60HZ
PhaseSingle-phase
Protect FeatureTotally Enclosed
EfficiencyIE 2
EU LVD VoltageLow voltage: Below 50Vac or 75Vdc
Wireless functionalityNo
Battery includedNo
High-concerned chemicalnone

4.2. AC Servo Motor Product Parameters

Attribute Value Attribute Value
ModelECX-F5CH230S-M2XN*KRated speed1500 RPM
Rated power2300 WIP65
Rated voltage220 VWeight10.0 Kg
Rated current12.4 AShaft diameter22mm
Flange130*130Torque of 750w Motor14.6N
Protection StructureIP65Insulation ClassF
EndoderMagnetic With 17bit AbusoluteEtherCATSupport
Standard Cable LengthSupportCustomized Cable LengthSupport
AC Servo Motor mechanical dimensions and product parameter table
Figure 4.1: AC Servo Motor mechanical dimensions and product parameter table.

4.3. AC Servo Drive Product Parameters

Attribute Value Attribute Value
ModelECX-30EL23Voltage(VAC)220
Continuous output current(Arms)12.4Frequency(Hz)50/60
Maximum output current(Arms)38.4Weight(KG)1.29
Power(KW)2.3
AC Servo Drive dimensions and parameters
Figure 4.2: AC Servo Drive dimensions and parameters, including terminal pin distribution.

4.4. Drive Specification Summary

Attribute Details
Output Power50W~7500W
Main Circuit Input Power SupplySingle-phase / three-phase AC220V-15%~+10% 50/60Hz
Control WayPosition control mode, Speed control mode, Trial control mode, JOG control mode, Torque control mode
Protect FunctionOverspeed/overvoltage of main power, overvoltage/overcurrent/overload/encoder abnormal/control power abnormal/position outpoor, etc.
Control ImportNegative limit, positive limit, Origin signal, CCW drive ban, CW drive ban, deviation counter zero, command pulse ban, CCW torque limit, CW torque limit
Energy Consumption BrakingBuilt-in/external, suit load less than 3 times the motor inertia
Control OutputServo is ready output, servo alarm output, positioning complete output, mechanical brake output
Position ControlInput mode Bus communication, Gear ratio shaft accuracy: 1-131072, Gear ratio motor precision: 17, 23, absolute value
Show OperateA 5-bit LED digital tube with 4 keys

4.5. Use Environment and Heat Dissipation

Attribute Value
Cooling MethodNatural cooling or forced air cooling
Service Environment (Occasion)Can be placed next to other heating equipment, to avoid dust, oil mist, corrosive gas, too high humidity and strong vibration place, prohibit combustible gas and conductive dust.
Service Environment (Temperature)0~50℃
Service Environment (Humidity)40~90%RH
Storage Temperature-20℃~65℃
Weight1.3 Kgs

Heat Dissipation Guidelines:

  • The reliable working environment temperature of the driver is usually within 50°C, and the motor working temperature is within 120°C.
  • When installing the drive, ensure the vertical side is positioned to allow heat dissipation fins to form strong air convection. Install a fan near the drive if necessary to force heat dissipation and maintain the drive within the reliable working temperature range.

5. Installation and Wiring

5.1. Wiring Diagram

Detailed wiring diagram for HLTNC servo driver and motor
Figure 5.1: Detailed wiring diagram for the HLTNC servo driver and motor, showing connections for main power, control signals, encoder, and motor power.

5.2. Wiring Instructions

  • Cable Length: Command cables should be within 3m, and encoder cables within 20m.
  • Power Supply: Verify correct power supply (single-phase 220VAC) and wiring for L1 and L2. Do not connect to 380VAC if only 220VAC is supported.
  • Motor Phase Sequence: Ensure the motor output terminals U, V, and W correspond one-to-one with the driver's terminals. Incorrect phase sequence can cause motor malfunction. The motor cannot be reversed by simply changing the three-phase terminal, unlike asynchronous motors.
  • Grounding: The motor grounding terminal must be connected to the servo driver's PE terminal and properly grounded due to high-frequency switching currents and potential leakage.
  • Output Signal Relays: Relays in the output signal path must have their absorption diodes connected in the correct direction to prevent signal output failure.
  • Noise Prevention: To prevent incorrect noise action, consider adding an insulation transformer and noise filter to the power supply.
  • Cable Routing: Route power lines (motor lines, power lines, etc.) at least 30cm away from signal lines, and avoid placing them in the same conduit.
  • External Power Supply Protection: Install a non-fuse circuit breaker to cut off the external power supply promptly if the drive fails.
  • Residual Voltage: Due to large electrolytic capacitors inside the servo drive, high voltage may persist after power-off. Wait at least 5 minutes after cutting off the power supply before touching the drive or motor.

5.3. Wire Specifications

Connection Symbol Wire Specification
Main Circuit Power SupplyL1, L21.5~4mm²
Motor Connection TerminalU, V, W1.5~4mm²
Earth Terminal1.5~4mm²
Control Signal TerminalCN10.14mm² (AWG 26), with shielding line
Encoder Signal TerminalCN20.14mm² (AWG 26), with shielding line
Brake Resistance TerminalP, D/P, C1.5~4mm²

Note:

  • Encoder cables must be twisted-pair. If the encoder cable is too long (> 20m), the power supply to the encoder may be insufficient. In such cases, the power supply and ground wires should be connected by multiple lines or use coarser wires.
  • Factory default for internal brake resistance is P and D short-connected.

5.4. Terminal Pin Distribution

The servo drive features various terminals for different functions:

  • CN1 (Input/Output Terminal): Used for general input and output signals. Refer to the detailed CN1 wiring terminal description in the official PDF manual for specific pin assignments and functions.
  • CN2 (Encoder Wiring Terminals):
    • Pins 5 (5V) and 6 (0V) for encoder power supply.
    • Pin 1 (SD+) for absolute value encoder communication positive end.
    • Pin 2 (SD-) for absolute value encoder communication negative end.
    • Pins 3 and 4 are dead ends (NC).
    • The metal shell serves as shield line protection.
  • CN3 (EtherCAT Bus Input Terminal) & CN4 (EtherCAT Bus Output Terminal): These terminals handle EtherCAT data communication.
    • E_TX+ and E_TX- for data transmission.
    • E_RX+ and E_RX- for data reception.
    • LED1 (orange) indicates Link/Activity IN status.
    • LED3 (orange) indicates Link/Activity OUT status.
    • LED2 and LED4 (green) indicate RUN state.
  • Main Circuit Terminals: Connect the main power supply (L1, L2), motor phases (U, V, W), and brake resistance (P, D, C). Ensure the drive ground terminal is connected to the power supply and motor ground.

6. Operation

6.1. Operation and Display Interface

The servo drive's panel features a 5-digit LED digital tube display and 4 keys (SET, UP, DOWN, ESC) for displaying system status and setting parameters. Operation is layered:

  • Parameter Setting: Select "P0-" in the first layer, press SET to enter, use UP/DOWN to modify values, and press SET again to confirm.
  • Panel Status Indication:
    • Control Mode: Displays the active control mode (e.g., PP, PV, PT, HM, CSP, CSV, CST).
    • Communication Status: Indicates initialization, pre-run, safe operation, or running state.
    • Servo State: Shows if the servo is not ready (nr), ready (ry), or in run move (rn).

6.2. Control Modes

The ECX series servo drive supports various control modes, each suited for different application requirements:

  • Periodic Synchronous Position Mode (CSP): The upper controller plans the position trajectory and sends the target position (607Ah) to the servo drive periodically. The servo drive then internally handles the position, speed, and torque control.
  • Periodic Synchronization Speed Mode (CSV): The upper controller sends the target speed (60FFh) and acceleration commands. The servo drive performs internal speed and torque adjustments.
  • Periodic Synchronous Torque Mode (CST): The upper controller sends the target torque (6071h) and torque ramp constant (6087h). The servo drive executes torque adjustments. If the speed reaches a predefined limit, the system transitions into speed regulation.
  • Outline Position Mode (PP): Primarily used for point-to-point positioning applications. The upper computer provides the target position (absolute or relative), speed, acceleration, and deceleration. The servo's internal trajectory generator creates the target position curve, and the driver manages position, speed, and torque control.
  • Contour Speed Mode (PV): The host computer sends target speed and acceleration values. The servo drive then internally manages speed and torque adjustments.
  • Outline Torque Mode (PT): Similar to CST, the upper controller sends the target torque (6071h) and torque ramp constant (6087h). The servo drive performs torque adjustments, entering speed regulation if the speed limit is reached.
  • Origin Back to Zero Mode (HM): This mode is used to find the mechanical origin and establish the position relationship between the mechanical origin and the mechanical zero. The mechanical origin is a fixed physical point, while the mechanical zero is the absolute zero position on the machine. After the homing process, the motor's stop position becomes the mechanical origin.

Video 6.1: Demonstration of multiple HLTNC servo motors and drivers operating in a synchronized test setup.

7. Maintenance and Inspection

Proper maintenance and inspection are crucial for the longevity and safe operation of your HLTNC servo motor kit. Always adhere to the following guidelines:

  • Electrical Safety:
    • Never touch the internal components of the driver or motor. This can cause severe electric shock.
    • Do not remove the drive panel while the power supply is connected.
    • After disconnecting power, wait at least 5 minutes before touching any wiring terminals to allow residual high voltage to dissipate.
    • Never change wiring or remove the servo motor when the power supply is active.
  • Environmental Checks: Regularly inspect the operating environment to ensure it remains free from excessive dust, oil mist, corrosive gases, and high humidity. Verify that the ambient temperature is within the specified range (0~50℃).
  • Physical Inspection: Check all cables and connections for signs of wear, corrosion, or looseness. Ensure all components are securely mounted.
  • Cooling System: Verify that the heat dissipation fins are clean and free from obstructions. If a fan is used for forced cooling, ensure it is operating correctly.

8. Troubleshooting

This section provides guidance on identifying and resolving common issues. For detailed fault codes and their specific handling measures, please refer to the official AC Servo Manual (PDF) available for download.

Official AC Servo Manual (PDF): For comprehensive troubleshooting and detailed technical information, please consult the AC Servo Manual (PDF).

8.1. Fault and Warning Handling During Startup

  • Digital Tube Does Not Light Up or Displays "ry":
    • Possible Causes: Power supply voltage fault, burning program short-connected, or servo drive failure.
    • Confirmation/Treatment: Check connections for CN1, CN2, CN3, CN4. Measure AC voltage (L1, L2, L3). Inspect burning program terminals for shorts. If issues persist, find the cause and troubleshoot.
  • Panel Displays "Er.": This indicates a fault. Identify the specific error code displayed.

8.2. General Fault and Warning Code Handling

Faults are classified by severity (Class 1, 2, or 3). "Restable" faults can be cleared by a reset signal. Reset methods include setting parameter POD-01=1, using DI function 2 (FunIN.2: ALM-RST), or setting bit 7 of control word 0x6040.

Common Fault Categories and General Solutions:

  • Parameter Errors (e.g., Er.101, Er.108, Er.D09): Often related to incorrect parameter settings or storage issues. Solutions typically involve system parameter recovery initialization, re-writing parameters, or replacing the servo drive if persistent.
  • Configuration/Software Errors (e.g., Er.102, Er.103, Er.104, Er.E11, Er.E12, Er.E13): Indicate issues with FPGA/MCU software versions, logic configuration, or network initialization. Solutions include updating software, burning device profiles, or replacing the servo drive.
  • Motor/Drive Mismatch (e.g., Er.120, Er.122): Occurs when the motor and drive are incompatible or incorrectly configured. Solution: Re-set motor number, check motor nameplate, or replace the motor/driver.
  • Electrical/Wiring Issues (e.g., Er.210, Er.400, Er.410, Er.420, Er.939): Relate to short circuits, over/under voltage, or broken power lines. Solutions involve checking and rewiring cables, increasing power supply capacity, or replacing components.
  • Overload/Overheating (e.g., Er.610, Er.620, Er.630, Er.650, Er.909, Er.920): Indicate excessive load or heat. Solutions include reducing load, increasing power supply capacity, improving cooling, adjusting gain, or replacing the servo drive/motor.
  • Encoder Errors (e.g., Er.731, Er.733, Er.735, Er.740, Er.770, Er.A33, Er.A34, Er.A35, Er.980): Pertain to encoder battery failure, data errors, interference, or internal faults. Solutions involve replacing the encoder battery, checking/rewiring encoder cables, or replacing the encoder.
  • Communication Errors (e.g., Er.E08, Er.E15): Indicate loss of synchronization signals. Solutions include checking wiring, grounding, and network connections.
  • Position/Speed Control Errors (e.g., Er.B00, Er.B01, Er.B02, Er.B03, Er.B04): Related to excessive position deviation, incorrect gear ratios, or full closed-loop function issues. Solutions involve reducing instruction increments, checking wiring, or adjusting parameters.

8.3. SDO Transmission Abort Codes

SDO (Service Data Object) transmission abort codes indicate issues during communication. Common codes include:

  • 0503 0000: Trigger sites did not change alternately.
  • 0504 0000: SDO protocol timed out.
  • 0504 0001: Illegal or unknown client/server command word.
  • 0504 0005: Memory overflow.
  • 0601 0000: Objects not supported for access.
  • 0602 0000: The object does not exist in the object dictionary.
  • 0604 0041: Object cannot be mapped to a PDO.
  • 0607 0010: Data type mismatch, service parameter length mismatch.
  • 0609 0030: Out of the value range of the parameter value.
  • 0800 0000: General fault.

For any SDO transmission issues, verify the communication setup, parameter values, and network configuration. Refer to the full manual for specific remedies for each code.

9. User Tips

  • Manual Availability: Always ensure you have access to the user manual for proper setup and troubleshooting. If a physical copy is missing, a digital version (PDF) is often available from the seller or manufacturer.
  • Initial Setup: Before connecting to a load, always perform a no-load test of the servo motor to verify basic functionality and prevent potential damage.
  • Wiring Verification: Double-check all wiring connections against the provided diagrams and specifications before applying power. Incorrect wiring is a common cause of faults.
  • Parameter Backup: After configuring your system, back up your parameter settings. This can save significant time during troubleshooting or if a reset is required.
  • Environmental Control: Maintain a clean, dry, and temperature-controlled environment for optimal performance and longevity of the servo kit.

10. Warranty and Support

For technical assistance, troubleshooting beyond the scope of this manual, or warranty inquiries, please contact the HLTNC Official Store directly. Ensure you have your product model number and purchase details ready for efficient support.

© 2023 HLTNC Official Store. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.