1. Introduction
The LEFOO LFDS10 Series Digital Pressure Controller is a high-precision differential pressure sensor designed for various industrial applications. It features a reliable sensor that converts pressure signals into standard industrial electrical signals for output and display. The device boasts a durable plastic shell, a high-contrast double-screen digital LCD for clear readings, and a user-friendly 3-key interface for easy operation and parameter adjustment. Its shock-resistant design ensures a long service life and stable performance.

2. Key Features
- High-reliability pressure sensing.
- Converts pressure signals to standard industrial electrical signals.
- Clear output and display on a high-contrast, double-screen digital LCD.
- Durable plastic shell design.
- User-friendly 3-key interface for easy navigation and parameter adjustment.
- Shock-resistant construction for extended service life.
- Multiple connection types available to suit various installation requirements.
- Configurable output types: Standard (2 switch interfaces), Current (1 switch + 4-20mA analog), Voltage (1 switch + 1-5V analog).
- Selectable switching value types: NPN or PNP.
- Adjustable hysteresis from 1 to 8 levels (default 3 levels).
3. Specifications
The following table details the technical specifications for the LFDS10 series:
| Parameter | LFDS102 (Low Pressure Type) | LFDS101 (High Pressure Type) |
|---|---|---|
| Pressure Type | Standard pressure | |
| Pressure Range | -100~100kPa | -100~1000kPa |
| Proof Pressure | 3 times | 1.5 times |
| Media | Non-hazardous gas only | |
| Rated voltage | 12~24VDC | |
| Current Consumption | <20mA (when no load) | |
| Switch output | NPN open collector transistor, Max current: 100mA, Pressure drop: <1.5V PNP open collector transistor, Max current: 100mA, Pressure drop: <1.5V | |
| Output Setting | NO/NC (Normally Open/Normally Closed) | |
| Hysteresis | 1-8 level (Default 3 level) | |
| Repeatability | ±0.3%F.S | |
| Comprehensive precision | ±1%F.S | |
| Response Time | 2.5/5/10/25/250/500/1000/5000ms (Selectable) | |
| Analog voltage output | 1-5V±5% (Available for voltage output type models) | |
| Analog current output | 4-20mA±5% (Available for current output type models) | |
| Storage Temperature | -10~60℃ | |
| Operating Temperature | 0~50℃ | |
| Temperature Character | ±2.5%F.S | |
| Enclosure | CN-14A-C2 (with connector cable, 2m) | |
Conversion Factors: 1kgf/cm² = 14.2psi, 1bar = 14.5psi
3.1 Ordering Reference
When ordering, refer to the following codes to specify the desired configuration:

- A (Pressure Range):
- 1 = High pressure type (-100~1000kPa)
- 2 = Low pressure type (-100~100kPa)
- B (Output Characters):
- S = Standard type (2 switch interfaces: PNP or NPN)
- A = Current output type (1 switch interface: PNP or NPN + 1 analog: 4-20mA)
- V = Voltage output type (1 switch interface: PNP or NPN + 1 analog: 1-5V)
- C (Connection Type):
- R = R1/8 + M5 Female screw
- E = G1/8 + M5 Female screw
- M = M5 Female screw
- D (Switching Value Type):
- N = NPN
- P = PNP
- E (Special Status):
- W = No special status
- X = Special specification
- J = Customized
4. Installation
4.1 Physical Installation
The LFDS10 series pressure controller is designed for easy integration. Ensure the installation location is free from excessive vibration, moisture, and extreme temperatures outside the operating range (0~50℃).
- Identify the appropriate pressure port connection (R1/8, G1/8, or M5 female screw) based on your system.
- Mount the device securely using the provided mounting points. Refer to the dimensional drawing for precise measurements and mounting hole locations.
- Ensure the pressure port is properly sealed to prevent leaks.

4.2 Electrical Connection
The LFDS10 comes with a CN-14A-C2 enclosure and a 2m connector cable. Connect the device to a 12-24VDC power supply. Observe proper polarity to avoid damage.
- Power Supply: Connect to a stable 12-24VDC power source.
- Switch Output: Depending on your model (Standard, Current, or Voltage type), the device provides NPN or PNP open collector transistor outputs. These outputs can handle a maximum current of 100mA with a pressure drop of less than 1.5V.
- Analog Output (for Current/Voltage types):
- Current Output Type: Provides a 4-20mA analog signal.
- Voltage Output Type: Provides a 1-5V analog signal.
Consult the specific wiring diagram provided with your product for detailed connection instructions. Ensure all connections are secure and insulated.
5. Operation
The LFDS10 features a 3-button interface and a double-screen digital display for easy configuration and monitoring.

5.1 Display Overview
The double-screen digital LCD simultaneously displays the current pressure reading and other configurable parameters or set points.
5.2 Button Functions
- Up Arrow Button (▲): Used to increase values or navigate upwards in menus.
- Down Arrow Button (▼): Used to decrease values or navigate downwards in menus.
- 'S' Button (Set/Enter): Used to enter the menu, confirm selections, or save settings.
5.3 Parameter Adjustment
Users can adjust various working parameters through the menu system. Common adjustable parameters include:
- Output Setting (NO/NC): Configure the switch output to be Normally Open or Normally Closed.
- Hysteresis: Adjust the difference between the switch-on and switch-off points. This can be set from 1 to 8 levels (default is 3 levels).
- Response Time: Select the desired response time for the sensor, ranging from 2.5ms to 5000ms.
- Pressure Units: (If applicable, check manual for specific models)
- Zero Point Adjustment: (If applicable, check manual for specific models)
General Procedure for Parameter Adjustment:
- Press and hold the 'S' button to enter the main menu.
- Use the Up (▲) and Down (▼) arrow buttons to navigate through the menu options.
- Press the 'S' button to select a parameter for adjustment.
- Use the Up (▲) and Down (▼) arrow buttons to change the value.
- Press the 'S' button again to confirm the new value and save it.
- Exit the menu by holding the 'S' button or waiting for a timeout.
Refer to the detailed programming guide in the full product manual for specific menu structures and advanced settings.
6. Maintenance
The LEFOO LFDS10 series is designed for low maintenance. Adhering to the following guidelines will help ensure optimal performance and longevity:
- Cleaning: Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning the exterior and display. Do not use abrasive cleaners or solvents.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges. Avoid exposing the device to corrosive gases or liquids.
- Pressure Port: Periodically check the pressure port for any blockages or contamination, especially if the measured media is not perfectly clean. Ensure connections remain tight.
- Cable and Connector: Inspect the connector cable for any signs of wear, damage, or loose connections.
- Calibration: While the sensor is factory calibrated, periodic re-calibration may be necessary for applications requiring extreme precision over long periods. Consult a qualified technician for calibration services.
Always disconnect power before performing any maintenance or inspection.
7. Troubleshooting
If you encounter issues with your LFDS10 pressure controller, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/No power | Incorrect power supply voltage or polarity; loose connection; faulty power supply. | Verify power supply (12-24VDC) and polarity. Check cable connections. Test power supply. |
| Inaccurate pressure reading | Sensor not properly installed; pressure port blockage; incorrect unit setting; sensor drift. | Ensure proper installation and sealing. Check for blockages. Verify unit settings in the menu. Consider re-calibration if drift is suspected. |
| Switch output not activating | Incorrect set point; hysteresis setting too wide; NO/NC setting incorrect; wiring error. | Check and adjust the set point and hysteresis. Verify NO/NC configuration. Inspect output wiring. |
| Analog output incorrect | Wiring error; incorrect analog output type selected (if configurable); load impedance mismatch. | Verify analog output wiring. Ensure the correct model (Current or Voltage type) is used. Check load impedance. |
| Buttons unresponsive | Temporary software glitch; physical button damage. | Power cycle the device. If problem persists, contact support. |
If the problem persists after attempting these solutions, please contact technical support.
8. User Tips
- For critical applications, always perform a functional test after installation and configuration to ensure the device operates as expected.
- When adjusting hysteresis, start with the default setting and fine-tune as needed for your specific application to prevent rapid switching or chattering.
- Consider the response time setting carefully; a faster response time might be suitable for dynamic systems, while a slower response can filter out noise in stable systems.
- Keep a record of your configuration settings for quick reference or if the device needs to be reset.
9. Warranty and Support
For information regarding product warranty, technical support, or service, please refer to the official LEFOO documentation or contact your supplier. Ensure you have your product model number (LFDS10) and any relevant purchase details ready when seeking support.