1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Hobbywing 30L Pump 18S. This electrical rubber flexible impeller water pump diaphragm is designed for agricultural drone applications, featuring an IP66 ingress protection rating and compatibility with 12S-18S Li-Po batteries. Please read this manual thoroughly before using the product.

2. Safety Warnings
- Always ensure the pump is disconnected from power before installation, maintenance, or troubleshooting.
- Operate the pump within the specified voltage range (12S-18S Li-Po) to prevent damage.
- Ensure all connections are secure and waterproof, especially given the IP66 rating.
- Do not operate the pump dry for extended periods.
- Keep hands and loose clothing away from moving parts during operation.
- This product is intended for use with agricultural drones. Do not use for purposes other than its intended application.
- WARNING: This product can expose you to chemicals including phthalates (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
3. Setup and Installation
3.1 Component Overview


3.2 Mounting the Pump
- Mount the pump securely to the drone frame using appropriate hardware. Refer to the CAD drawing for mounting dimensions.
- Ensure the pump is positioned to allow for proper water inlet and outlet connections without kinking hoses.

3.3 Water Pipe Connection
- The inlet and outlet outer diameter is 20.53mm. It is recommended to use water pipes with an inner diameter of 19mm for optimal fit and performance.
- Secure all water pipe connections with clamps to prevent leaks.
3.4 Electrical Wiring
Connect the pump to your drone's power and control system according to the pin definitions below. Ensure correct polarity and secure connections.
| Pin Harness Color | Pin Definition |
|---|---|
| Red | Power+ |
| Purple | Throttle/TS |
| Black | Power Ground |
| Blue | CAN-H |
| Green | CAN-L |
- The pump is compatible with 12S-18S Li-Po batteries. Ensure your power source matches this requirement.
- The control mode supports both PWM and CAN. Connect the appropriate control lines based on your drone's flight controller.
4. Operating Instructions
4.1 Pre-Operation Checklist
- Verify all electrical connections are secure and insulated.
- Confirm water pipes are correctly attached and free from kinks or blockages.
- Ensure the water tank contains sufficient liquid for pumping.
- Check that the battery voltage is within the 12S-18S range.
4.2 Starting the Pump
- Power on your drone system.
- Control the pump via PWM or CAN signals from your flight controller. The throttle range is fixed at 1050-1950 μs.
- Note that throttle calibration is not supported for this pump.
- Observe the pump's operation to ensure smooth flow and no unusual noises or vibrations.
4.3 Stopping the Pump
- Reduce the throttle signal to the minimum or send a stop command via CAN.
- Power off the drone system after use.
5. Maintenance
5.1 Regular Checks
- Inspect water pipes and connections for wear, damage, or leaks before each use.
- Check electrical wiring for any signs of fraying or corrosion.
- Ensure the pump's exterior is clean and free from debris.
5.2 Cleaning
- After use, especially with agricultural chemicals, flush the pump with clean water to prevent residue buildup.
- Wipe down the exterior with a damp cloth. Do not use harsh chemicals that could damage the composite material or rubber components.
5.3 Storage
- Store the pump in a dry environment with temperatures between -10℃ and 50℃.
- Ensure storage humidity is ≤85%.
- Protect the pump from direct sunlight and extreme temperatures.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; Incorrect wiring; Faulty ESC/controller signal | Check battery connection and voltage; Verify wiring against diagram; Test ESC/controller output. |
| Low or no water flow | Empty tank; Kinked or blocked hose; Air in the system; Impeller damage | Refill tank; Inspect and clear hoses; Prime the pump if necessary; Inspect impeller for damage. |
| Water leakage | Loose pipe connections; Damaged seals/hoses | Tighten hose clamps; Inspect and replace damaged pipes or seals. |
| Unusual noise/vibration | Debris in pump; Loose mounting; Worn bearings | Disconnect power and inspect pump for foreign objects; Ensure pump is securely mounted; Contact support if noise persists. |
7. Specifications

| Parameter | Value |
|---|---|
| Product Model | Combo-pump-30L-18S |
| Material | Composite Material |
| Total Weight | 516g |
| Size (L*W*H) | 91*110*67mm |
| Recommended Battery | 12S-18S (Li-Po) |
| Rated Flow | 20 L/min |
| Maximum Flow | 30 L/min |
| Rated Power | 80W |
| Maximum Power | 110W |
| Rated Current | 4A |
| Max Current | 10A |
| Compatible Voltage | 12S-18S |
| Operating Temperature | 0~50℃ |
| Ingress Protection | IP66 |
| Inlet & Outlet Outer Diameter | 20.53mm (Recommend water pipe inner diameter 19mm) |
| Cable | 180mm Teflon-6 cable and male connector (GND-yellow, S(PWM)-purple, CH-blue, CL-green, +-red, GND-black) |
| Parameter | Value |
|---|---|
| ESC Model | XRotor-10A-FOC |
| PWM High Level | 3.3V/5V |
| Throttle (μs) | Fixed 1050-1950 |
| Throttle Calibration | Nonsupport |
| Frequency | 50-500Hz |
| Communication Method | CAN |
| Control Mode | PWM+CAN |
| Continuous Current | 4A |
| Instantaneous Current | 10A |
| Controller CAN Resistance | No |
| PCB Hardware Version (CAN-ESC) | PCB-HW5116_YT1_V1.2 |
| ESC-Driver Firmware (CAN-ESC) | HW5116_KZ1_V1_C04TG4517S100Z-20246061 |
| CAN Communication Version | CAN-04.1.13 |
| CAN Communication Protocol | UAVCAN(HWCAN) |
| Item | Parameter |
|---|---|
| NSS Salt Spray Test | 72h |
| Ingress Protection | IP66 |
| Operating Temperature | 0~50℃ |
| Operating Humidity | 5%~95% |
| Storage Temperature | -10~50℃ |
| Storage Humidity | ≤85% |
7.1 Performance Data

The Flow-RPM curve (Figure 6) provides a visual representation of the pump's flow rate (L/min) across different RPMs, indicating its performance characteristics.
8. User Tips
- Voltage Consistency: Always ensure your battery voltage is stable and within the 12S-18S range to prevent pump damage and ensure consistent performance.
- Pipe Sizing: Using the recommended 19mm inner diameter water pipes will optimize flow and reduce strain on the pump.
- Pre-Flight Check: Before each flight, quickly check all hose connections for tightness and ensure there are no visible leaks.
- Post-Operation Flush: If using the pump for spraying chemicals, a thorough flush with clean water after each use can significantly extend the pump's lifespan and prevent chemical buildup.
- Environmental Awareness: While the pump is IP66 rated, avoid prolonged exposure to extreme conditions outside the specified operating and storage temperatures.
9. Warranty and Support
For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer/manufacturer directly.
For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact the official Hobbywing support channels or your authorized dealer.