DIANQI AHC30A/AHC30B

Contents

AHC30A/AHC30B Digital Programmable Time Switch User Manual

Model: AHC30A / AHC30B | Brand: DIANQI

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the DIANQI AHC30A and AHC30B series weekly programmable digital time switches. These devices are designed for precise control of electrical circuits based on a weekly schedule, offering reliability and ease of use for various applications.

2. Safety Information

  • Always disconnect power before installation or maintenance to prevent electric shock.
  • Installation should be performed by a qualified electrician in accordance with local electrical codes.
  • Ensure the device's voltage and current ratings match your application requirements.
  • Do not expose the device to moisture or extreme temperatures outside its specified operating range.
  • Verify all connections are secure before restoring power.

3. Product Overview

The AHC30A and AHC30B are compact, DIN rail mountable digital time switches featuring an LCD display and intuitive button controls for programming. They are designed for weekly scheduling of electrical loads up to 30A.

3.1 Components

Front view of two digital programmable timers (AHC30A and AHC30B models), showing LCD display, control buttons (P, D+, H+, M+, RESET, MANUAL), and terminal connections.
Figure 1: Front view of AHC30A and AHC30B Digital Programmable Time Switches

The timer features:

  • LCD Display: Shows current time, day, and program status.
  • P (Program) Button: Enters program setting mode.
  • D+ (Day) Button: Adjusts the day of the week during time/program setting.
  • H+ (Hour) Button: Adjusts the hour during time/program setting.
  • M+ (Minute) Button: Adjusts the minute during time/program setting.
  • RESET Button: Clears all settings and resets the timer.
  • MANUAL Button: Allows for manual override of the programmed schedule (ON/AUTO/OFF).
  • Input Terminals (1, 2): For connecting the main power supply.
  • Output Terminals (AHC30A: 5, 4, 3; AHC30B: 5, 3): For connecting the load to be controlled.

3.2 Dimensions

Side view of the timer with detailed dimensions in millimeters (45mm, 65mm, 48mm, 25mm, 35mm, 85mm).
Figure 2: Side view with dimensions
Angled view of the timer, highlighting its compact design and showing model information (KG316T/THC15B, AHC30A/B, 30A) and CE marking.
Figure 3: Angled view with additional dimensions

Approximate dimensions:

  • Length: 85mm
  • Width: 35mm
  • Height: 65mm

4. Specifications

FeatureSpecification
Product NameSmall Time-Control Switch
ModelAHC30A / AHC30B
BrandDIANQI
Working Power SupplyAC 220V 50Hz (also supports 380V configurations)
Rated Current30A
Display DeviceLCD Display
Ambient Temperature-10°C to 40°C
MaterialPlastic
Item TypeSWITCHES
OriginMainland China

5. Installation and Wiring

The time switch is designed for DIN rail mounting. Ensure proper ventilation and avoid installing near heat sources or in direct sunlight. Follow the specific wiring diagrams below for your model and voltage requirements.

5.1 AHC30A Wiring Diagrams

5.1.1 AHC30A 220V AC Connection

Wiring diagram for AHC30A model, showing connection for 220V AC input (L, N) and output load, utilizing terminals 1, 2 for input and 5, 4, 3 for output.
Figure 4: AHC30A 220V AC Wiring Diagram

For 220V AC applications:

  • Connect the Live (L) wire of the 220V AC supply to terminal 1.
  • Connect the Neutral (N) wire of the 220V AC supply to terminal 2.
  • Connect the load to be controlled between terminal 3 (normally closed contact) or terminal 4 (normally open contact) and terminal 5 (common contact).
  • Ensure the load's power requirements do not exceed 30A.

5.1.2 AHC30A 380V AC 3-Phase Connection (with Contactor)

Circuit diagram for AHC30A model, illustrating connection for 380V AC 3-phase input (A, B, C, N) and output load, with an external AC308V contactor (CJ).
Figure 5: AHC30A 380V AC 3-Phase Circuit Diagram

For 380V AC 3-phase applications, an external contactor (CJ) is required:

  • Connect the 3-phase input (A, B, C) and Neutral (N) to the main terminals of the contactor.
  • Connect the 220V AC control voltage (L, N) to terminals 1 and 2 of the AHC30A timer.
  • Connect the output of the AHC30A timer (e.g., terminals 4 and 5) to the coil of the external contactor (CJ) to control its operation.
  • The 380V load is then connected to the output terminals of the contactor.

5.2 AHC30B Wiring Diagrams

5.2.1 AHC30B 220V AC Connection

Wiring diagram for AHC30B model, showing connection for 220V AC input (L, N) and output load, utilizing terminals 1, 2 for input and 5, 3 for output.
Figure 6: AHC30B 220V AC Wiring Diagram

For 220V AC applications:

  • Connect the Live (L) wire of the 220V AC supply to terminal 1.
  • Connect the Neutral (N) wire of the 220V AC supply to terminal 2.
  • Connect the load to be controlled between terminal 3 and terminal 5.
  • Ensure the load's power requirements do not exceed 30A.

5.2.2 AHC30B 380V AC 3-Phase Connection (with Contactor)

Circuit diagram for AHC30B model, illustrating connection for 380V AC 3-phase input (A, B, C, N) and output load, with an external AC220V contactor (CJ).
Figure 7: AHC30B 380V AC 3-Phase Circuit Diagram

For 380V AC 3-phase applications, an external contactor (CJ) is required:

  • Connect the 3-phase input (A, B, C) and Neutral (N) to the main terminals of the contactor.
  • Connect the 220V AC control voltage (L, N) to terminals 1 and 2 of the AHC30B timer.
  • Connect the output of the AHC30B timer (e.g., terminals 3 and 5) to the coil of the external contactor (CJ) to control its operation.
  • The 380V load is then connected to the output terminals of the contactor.

6. Operating Instructions

6.1 Initial Setup and Time Setting

  1. Power On: After wiring, apply power to the timer. The LCD display should light up.
  2. Reset: Press the 'RESET' button to clear any previous settings and ensure a fresh start.
  3. Set Current Time:
    • Press the 'D+' button to set the current day of the week.
    • Press the 'H+' button to set the current hour.
    • Press the 'M+' button to set the current minute.

6.2 Programming ON/OFF Cycles

The timer allows for multiple ON/OFF programs per day. Follow these steps to set your desired schedule:

  1. Enter Program Mode: Press the 'P' button once. The display will show '1 ON' (for the first ON program).
  2. Set ON Time: Use 'D+', 'H+', 'M+' buttons to set the desired day(s), hour, and minute for the first ON event. You can select individual days, weekdays, weekends, or all days.
  3. Set OFF Time: Press 'P' again. The display will show '1 OFF'. Use 'D+', 'H+', 'M+' buttons to set the desired day(s), hour, and minute for the first OFF event.
  4. Add More Programs: Repeat steps 2 and 3 for additional ON/OFF programs (e.g., '2 ON', '2 OFF', etc.). The timer typically supports up to 8 or more ON/OFF programs.
  5. Exit Program Mode: After setting all desired programs, press the 'P' button repeatedly until the display returns to the current time, or wait for a few seconds for it to exit automatically.

6.3 Manual Override

The 'MANUAL' button allows you to temporarily override the programmed schedule:

  • Press 'MANUAL' once: Switches the output to ON (if currently OFF) or OFF (if currently ON), and sets the mode to 'MANUAL ON' or 'MANUAL OFF'.
  • Press 'MANUAL' again: Cycles through 'ON', 'AUTO', 'OFF' modes.
  • In 'AUTO' mode, the timer follows the programmed schedule.

7. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Battery Backup: The timer typically includes an internal battery for retaining settings during power outages. If the display is blank or settings are lost frequently, the internal battery may need replacement by a qualified technician.
  • Terminal Check: Periodically check terminal connections to ensure they are tight and free from corrosion.

8. Troubleshooting

ProblemPossible CauseSolution
Display is blankNo power supply; Internal battery depletedCheck power connections; If power is present, internal battery may need service.
Timer not switching ON/OFF as programmedIncorrect program settings; Manual override active; Incorrect current time/dayReview and correct program settings; Ensure mode is 'AUTO'; Verify current time and day are accurate.
Load not receiving power when timer is ONLoose wiring; Faulty load; Overload protection trippedCheck all wiring connections; Test the load directly; Check circuit breaker/fuse.
Buttons unresponsiveTemporary software glitchPress the 'RESET' button. If issue persists, disconnect power for a few minutes and retry.

9. User Tips

  • For critical applications, consider using the timer to control a contactor, especially for high-current or 3-phase loads, to extend the life of the timer's internal relay.
  • Always double-check your programmed ON/OFF times and days to avoid unexpected operation.
  • Utilize the 'MANUAL' override function for temporary changes without altering your programmed schedule.

10. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.