1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Mirage Nex Setchf120T Minisplit Air Conditioner. Please read this manual thoroughly before using the appliance and keep it for future reference.
2. Safety Information
Always observe the following basic precautions to reduce the risk of fire, electric shock, or injury:
- Ensure the unit is connected to a properly grounded 110V AC power source.
- Do not operate the unit with wet hands.
- Do not insert objects into the air outlet or inlet.
- Keep the area around the unit clear to ensure proper airflow.
- Turn off the power supply before performing any maintenance or cleaning.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. Product Overview
The Mirage Nex Setchf120T is a 1-ton, 110V, cooling-only minisplit air conditioner designed for room use. It features an environmentally conscious design, energy-saving functions, and low noise operation.
Key Features:
- Bio Care: Utilizes environmentally friendly refrigerant that does not damage the ozone layer.
- Inteli-comfort: Minimizes temperature fluctuations for consistent comfort.
- Eco mode: Energy-saving operation mode that optimizes compressor cycles.
- Low Noise: Designed for quiet operation (24-35dB indoor machine noise).
- Energy Save: Progressive start-up function to maintain reasonable energy consumption.
- Cleaning: Active routine cleaning of the evaporator coil to remove accumulated dirt.
- Multi Fan: Offers 5 ventilation options: Low, Medium, High, Auto, and TURBO.
Components:
The system consists of an indoor unit and an outdoor unit. This manual primarily focuses on the indoor unit's operation and maintenance.

Figure 1: Front view of the indoor unit

Figure 2: Right-angled view of the indoor unit

Figure 3: Left-angled view of the indoor unit

Figure 4: Side view of the indoor unit
4. Setup and Installation
Installation of a minisplit air conditioner requires specialized knowledge and tools. It is highly recommended that installation be performed by a qualified and certified HVAC technician to ensure proper function, safety, and compliance with local regulations.
General Considerations:
- Location: Choose a location for the indoor unit that allows for optimal air distribution throughout the room and easy access for maintenance. The outdoor unit should be placed in a well-ventilated area, away from direct sunlight and obstructions.
- Power Supply: Ensure the electrical supply meets the unit's requirements (110V AC). A dedicated circuit is often recommended.
- Drainage: Proper drainage for condensate water from the indoor unit must be established.
- Refrigerant Lines: The refrigerant lines connecting the indoor and outdoor units must be correctly sized, insulated, and sealed.
Refer to the detailed installation guide provided with the physical product for specific instructions, diagrams, and safety warnings relevant to the installation process.
5. Operating Instructions
Your Mirage Nex Setchf120T air conditioner is controlled via a remote control (not pictured, but typically included). Familiarize yourself with the remote's buttons and display.
Basic Operation:
- Power On/Off: Press the POWER button to turn the unit on or off.
- Mode Selection: Since this is a cooling-only unit, the primary mode will be COOL. Select this mode using the MODE button on your remote.
- Temperature Adjustment: Use the UP/DOWN arrows to set your desired temperature. The unit will cool the room to this set point.
- Fan Speed: Use the FAN button to cycle through the available fan speeds: Low, Medium, High, Auto, and TURBO.
Special Functions:
- Eco Mode: Activate Eco mode for energy-efficient operation. This mode intelligently adjusts compressor cycles to save power while maintaining comfort.
- Multi Fan: Utilize the Multi Fan feature to select from 5 different ventilation options, including a powerful TURBO setting for rapid cooling.
- Inteli-comfort: This feature works automatically to minimize temperature fluctuations, providing a more stable and comfortable environment.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your air conditioner.
Filter Cleaning:
The air filters should be cleaned regularly (e.g., every two weeks or as needed, depending on usage and air quality). Refer to your product's specific instructions for how to remove and clean the filters. Typically, they can be washed with mild detergent and water, then thoroughly dried before reinstallation.
Evaporator Cleaning (Cleaning Feature):
Your unit includes an active routine cleaning feature for the evaporator coil. Consult your remote control or product manual for instructions on how to activate this function. This helps remove dirt and maintain cooling efficiency.
General Cleaning:
- Wipe the exterior of the indoor unit with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Ensure the outdoor unit's coils are free from debris (leaves, dirt, etc.) to maintain efficient heat exchange. This may require professional cleaning annually.
Professional Servicing:
It is recommended to have your air conditioner professionally serviced at least once a year. A technician can check refrigerant levels, clean coils, inspect electrical connections, and ensure all components are functioning correctly.
7. Troubleshooting
Before contacting customer support, try the following basic troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply; Remote control batteries dead | Check circuit breaker; Replace remote control batteries |
| Insufficient cooling | Dirty air filters; Blocked outdoor unit; Doors/windows open; Temperature setting too high | Clean air filters; Clear obstructions from outdoor unit; Close doors/windows; Lower temperature setting |
| Unusual noise | Loose parts; Obstruction in fan; Unit not level | Turn off and inspect for loose parts or obstructions; Ensure unit is level. If noise persists, contact a technician. |
| Water leakage from indoor unit | Clogged drain pipe; Unit not level | Check and clear drain pipe; Ensure unit is level. Contact a technician if problem persists. |
For problems not listed here or if solutions do not resolve the issue, please contact a qualified service technician.
8. Specifications
| Attribute | Specification |
|---|---|
| Brand Name | MIRAGE |
| Model Number | SETCHF120T |
| Type | Minisplit, Ceiling |
| Cooling/Heating | Cooling Only |
| Power Source | AC |
| Voltage | 110 V |
| Capacity | 1 Ton |
| Indoor Machine Noise | 24-35dB |
| Feature | Save Energy |
| Use | ROOM |
| Seasonal Energy Efficiency Ratio (SEER) | 12 |
| Condition | New |
| Origin | Mainland China |
9. Warranty and Support
For warranty information, please refer to the warranty card included with your product or contact the retailer/manufacturer directly. Keep your purchase receipt as proof of purchase.
For technical support or service inquiries, please contact Mirage customer service. When contacting support, please have your model number (SETCHF120T) and serial number ready.