CEM DT-3809

Contents

CEM DT-3809 Digital LED Light Meter Instruction Manual

Model: DT-3809 | Brand: CEM

1. Introduction

The CEM DT-3809 is a professional digital LED light meter designed for measuring the intensities of illumination in units of Lux or Foot-candle. It is suitable for measuring various light sources, including all visible ranges, and adheres to JISC1609:1993 and CNS 5119 general A class specifications. This manual provides detailed instructions for the safe and effective use of your device.

2. Safety Information

Please read all safety information before operating the device. Failure to follow these instructions may result in electric shock, fire, or personal injury.

  • Always ensure the device is clean and free from dust or moisture before use.
  • Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
  • Keep the device away from extreme temperatures, humidity, and direct sunlight.
  • Remove the battery if the device is not to be used for an extended period.

3. Product Overview

The DT-3809 LED Light Meter consists of a main unit with a digital display and control buttons, and an external light sensor connected via an approximately 1.5-meter cable. The external sensor allows for flexible positioning during measurements.

CEM DT-3809 LED Light Meter with display and buttons

Figure 1: CEM DT-3809 LED Light Meter Main Unit

3.1 Key Components

  • Digital Display: Shows MAX, current LUX/FC reading, Light Source setting, and battery indicator.
  • Light Sensor: External sensor with a protective cap, connected by a 1.5M cable.
  • Buttons:
    • Power Button (red): Turns the device On/Off.
    • LX/FC CD Button: Toggles between Lux and Foot-candle units.
    • MEM READ Button: Accesses data storage and recall functions.
    • HOLD L.S. Button: Activates data hold and light source selection.
    • Up/Down Arrows: Navigates menus and adjusts settings.
    • ZERO Button: Performs zero adjustment.
CEM DT-3809 LED Light Meter with external light sensor

Figure 2: DT-3809 Light Meter with Detachable Sensor

4. Setup

4.1 Battery Installation

The DT-3809 requires a 9V battery (included). To install:

  1. Locate the battery compartment cover on the back of the device.
  2. Slide or unclip the cover to open.
  3. Insert a 9V battery, observing the correct polarity (+/-).
  4. Replace the battery compartment cover securely.

4.2 Connecting the Light Sensor

The light sensor is permanently attached to the main unit via a coiled cable. Ensure the cable is not strained or damaged. Remove the protective cap from the light sensor before taking measurements.

5. Operating Instructions

5.1 Power On/Off

Press the red power button (Power button icon) to turn the device on. Press and hold the same button to turn it off.

5.2 Unit Selection (Lux/Foot-candle)

Press the LX/FC CD button to toggle between Lux (lx) and Foot-candle (fc) measurement units. The selected unit will be displayed on the screen.

5.3 Taking Measurements

  1. Turn on the device.
  2. Remove the protective cap from the light sensor.
  3. Position the light sensor at the location where you want to measure light intensity. Ensure the sensor is facing the light source directly for accurate readings.
  4. The current light intensity will be displayed on the screen in the selected unit.
CEM DT-3809 measuring LED light

Figure 3: Measuring LED light with DT-3809

5.4 Light Source Selection

The DT-3809 features a spectral response close to CIE luminous spectral efficiency and can measure various light sources. To select the light source type:

  1. Press and hold the HOLD L.S. button to enter Light Source selection mode.
  2. Use the Up/Down arrow buttons to cycle through options like Tungsten/Daylight, Fluorescent, and 0-9 select ratings.
  3. Press HOLD L.S. again to confirm your selection.

5.5 Data Hold

Press the HOLD L.S. button briefly during measurement to freeze the current reading on the display. Press it again to release the hold and resume live measurement.

5.6 Max/Min Readings

The device automatically tracks maximum and minimum values. These can typically be viewed by pressing a dedicated button (often labeled 'MAX' or 'MIN' or accessed via the 'MEM READ' button, depending on the specific firmware version).

5.7 Zero Adjustment

To ensure accuracy, perform a zero adjustment in a dark environment (with the sensor cap on or in complete darkness). Press the ZERO button to calibrate the device to zero illumination.

5.8 Data Storage and Recall (99 Records)

The DT-3809 can store up to 99 measurement records. Use the MEM READ button to access the memory functions. Follow the on-screen prompts and use the Up/Down arrows to save or recall data.

6. Maintenance

6.1 Cleaning

Wipe the device and sensor with a soft, dry cloth. Do not use abrasive cleaners or solvents. Keep the light sensor clean and free of smudges or dust for accurate readings.

6.2 Battery Replacement

When the low battery indicator appears on the display, replace the 9V battery as described in Section 4.1. Dispose of old batteries responsibly.

6.3 Storage

Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Always place the protective cap on the light sensor when not in use.

7. Troubleshooting

  • Device does not power on: Check battery installation and ensure the battery has sufficient charge. Replace if necessary.
  • Inaccurate readings: Ensure the light sensor is clean and the protective cap is removed. Perform a zero adjustment in a dark environment. Verify the correct light source type is selected.
  • Display is blank or frozen: Try turning the device off and on again. If the issue persists, replace the battery.

8. Specifications

Table of CEM DT-3809 specifications

Figure 4: DT-3809 Specifications Table

FeatureDescription
Model NumberDT-3809
Light Source SelectingTungsten/Daylight, Fluorescent, 0~9 select rating
Measuring Range40, 400, 4,000, 40,000, 400,000 Lux; 40, 400, 4,000, 40,000 Foot-candle
Accuracy+/-3% (Calibrated to standard incandescent lamp 2856K and corrected LED day while-light spectrum). +/-6% other visible light source.
Records Storage99 records
Length of wire for light sensorApproximately 1.5M
Size (HxWxD)160mm x 58mm x 27mm
Weight280g
Battery IncludedNo (Requires 9V battery)
CertificationCE

9. User Tips

  • For the most accurate readings, ensure the light sensor is positioned perpendicular to the light source.
  • Regularly check the battery level, especially before critical measurements.
  • Utilize the data hold function when taking readings in hard-to-reach areas or when you need to record a specific value.
  • The 99-record storage is useful for tracking light changes over time or comparing different locations.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

11. Company Overview

CEM (Shenzhen Everbest Machinery Industry Co., Ltd.) is a leading professional instrument manufacturer established in 1991. They specialize in R&D, production, and marketing of various professional measuring instruments, including thermal imagers, infrared thermometers, digital multimeters, clamp meters, and environmental meters. CEM is committed to providing accurate, reliable, and versatile test instruments and solutions across various industries.

Video 1: CEM Company Overview - Showcasing their range of precision measurement instruments and commitment to quality.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.