1. Introduction
The WITRN CC1 is a compact, high-precision USB Type-C voltage and current meter designed for comprehensive power delivery testing. It supports the latest PD3.1 standard, allowing for measurements up to 28V. With its vibrant color digital display, the CC1 provides real-time data on voltage, current, and power, making it an essential tool for electronics enthusiasts, technicians, and anyone working with USB-C power systems.

2. Key Features
- PD3.1 Support: Capable of measuring up to 28V, compatible with the latest Power Delivery standards.
- High-Precision Measurement: Equipped with a 16-bit independent INA226 ADC chip for accurate voltage, current, and power readings.
- Bi-directional Current Sampling: Allows for precise measurement of current flow in both directions.
- Color Digital Display: A clear 0.96-inch IPS screen with 160x80 resolution for easy data visualization.
- Real-time Data: Displays voltage (U), current (I), and power (P) simultaneously.
- Capacity Recording: Features EEPROM for offline storage of charging capacity data, including average and peak values.
- EPR PD Monitoring: Includes a simple listening function for Power Delivery protocol analysis.
- Built-in DC Buck Circuit: Ensures stable operation even with high voltage inputs.
- Compact Design: Small and portable, approximately 31.8 x 16.1 x 8.1mm (excluding connector).
- Durable Connectors: Custom extended high-conductivity USB-C male connector and KR high-contact impedance USB-C female connector.


3. Setup Guide
The WITRN CC1 is designed for plug-and-play operation. Follow these steps to begin using your device:
- Connect to Power Source: Insert the male USB-C connector of the WITRN CC1 into your USB-C power adapter, power bank, or any USB-C power source.
- Connect Device Under Test: Plug the USB-C cable from the device you wish to test (e.g., smartphone, laptop, or other USB-C powered device) into the female USB-C port on the WITRN CC1.
- Power On: The CC1 will automatically power on and display real-time voltage, current, and power readings as soon as a power connection is established.
- Optional: Kelvin Test Kit: For precise internal resistance measurements of cables, connect the optional UL004 Kelvin test kit (sold separately) to the designated ports on the CC1, following the kit's instructions.
4. Operating Instructions
The WITRN CC1 features two buttons for navigation and mode selection. While specific button functions may vary with firmware updates, the general operation involves:
- Real-time Display: Upon connection, the main screen will show:
- U (Voltage): In Volts (V)
- I (Current): In Amperes (A)
- P (Power): In Watts (W)
- Navigating Menus: Use the two buttons (typically short press for selection/next, long press for menu/back) to cycle through different display modes or access settings. Common modes include:
- Capacity/Energy Recording: View accumulated Watt-hours (Wh) and Ampere-hours (Ah). The device stores this data offline in its EEPROM.
- PD Monitoring: Access a simple listening mode to observe Power Delivery negotiation protocols. Note that some fast charging devices may not be fully compatible with this monitoring function.
- Fast Charge Trigger: The device supports triggering various fast charge protocols. This function is for testing purposes and should be used with caution.
- Data Groups: The CC1 supports 1 data group for recording.
- Interpreting Fast Charge Display: The fast charge display shows D+D- voltage and working current PD negotiation for reference only. It is not guaranteed to be perfectly accurate for all protocols.
5. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using liquids or abrasive cleaners.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Handling: Handle the device with care. Avoid dropping it or subjecting it to strong impacts.
- Disassembly: Do not attempt to disassemble or repair the device yourself, as this will void any warranty and may cause damage.
6. Troubleshooting
- No display when connected:
- Ensure both the input and output USB-C connections are secure. Verify that the power source is active and providing power. Try a different power source or cable.
- Incorrect or fluctuating readings:
- Check all cable connections for looseness or damage. Ensure the device under test is functioning correctly. High-resistance or poor-quality cables can affect readings; consider using a known good cable.
- Device unresponsive:
- Disconnect the CC1 from all power sources and devices, wait a few seconds, then reconnect. If the issue persists, contact customer support.
- PD monitoring not working with certain devices:
- The PD monitoring function is a simple listening mode and may not be compatible with all fast charging devices or proprietary protocols. This is expected behavior for some setups.
7. Specifications

| Feature | Specification |
|---|---|
| Model | CC1 |
| CPU | RisCV 32bit |
| Screen | 0.96 inch IPS, 160x80 resolution |
| Operating System | Single task |
| UI Language | Firmware |
| Voltage Measurement Range | PD3.1 4-36V |
| Current Measurement Range | 0-10A (Max) |
| Capacity Storage | EEPROM (offline recording, power-off save) |
| Main Interface | USB-C (TYPE-C 24P) |
| ADC Chip | TI INA226 (16-bit high precision) |
| Voltage Resolution | 0.0001V |
| Current Resolution | 0.0001A |
| Power Resolution | 0.001W |
| Measurement Accuracy | ±1% |
| Working Voltage | 4-28V (peak 36V) |
| Working Current | 0-6A (short peak 10A) |
| Capacity Measurement Range | 0-9999Wh |
| Buttons | 2 (Japanese ALPS brand) |
| PD3.1 EPR + AVS Support | Yes |
| Fast Charge Protocol Detection/Trigger | QC3.0/QC4+/PPS, FCP/SCP, VOOC/Dash, PD2.0/PD3.0/QC4+/QC5, MTK PE1.1/PE2.0 |
| Built-in DC Buck Circuit | Yes |
| Product Size | Approx. 31.8 x 16.1 x 8.1mm (excluding USB-C male connector) |


8. User Tips
- Verify Charger Output: Use the CC1 to quickly check if your USB-C charger is delivering the advertised voltage and current.
- Assess Cable Quality: By observing the voltage drop across a cable under load, you can get an indication of its quality and resistance. A significant voltage drop suggests a lower quality or longer cable.
- Monitor Battery Charging: Track the total Watt-hours (Wh) or Ampere-hours (Ah) delivered to your device's battery to understand its charging efficiency and capacity over time.
- Test Device Compatibility: Use the PD monitoring function to see if your device and charger are negotiating the expected Power Delivery profiles.
9. Warranty and Support
The WITRN CC1 is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and duration, please refer to the documentation provided at the time of purchase or contact your retailer.
For technical support, troubleshooting assistance, or inquiries regarding product functionality, please contact the manufacturer's customer service or your authorized dealer. Keep your purchase receipt or proof of purchase handy when seeking support.