1. Introduction
The Mindray MR-96A Elisa Reader is a sophisticated medical laboratory instrument designed for accurate and efficient clinical examination and diagnosis, particularly in applications such as clinical semen detection. Featuring a large color LCD touchscreen and a built-in thermal printer, this microplate reader offers user-friendly operation and reliable performance for various laboratory needs.

2. Key Features
- Display: 7.8-inch color LCD touchscreen with touch pen and pop-up keypad for intuitive navigation.
- Shaking Modes: Variable time and speed shaking modes to accommodate diverse assay requirements.
- Data Storage: High-capacity memory capable of storing up to 20,000 results.
- Printing: Integrated thermal printer for immediate result printouts.
- Connectivity: Equipped with 1 x RS232 port for external PC control and 2 x USB ports for connecting external mouse, keyboard, or printer.
- Application: Suitable for clinical examination aids, microplate reading, and diagnosis, including clinical semen detection.
3. Specifications
| Parameter | Value |
|---|---|
| Reading Range | 0.001~3.500 Abs |
| Measurement Range | 0.001~2.500 Abs |
| Display | Large Color LCD Display (7.8" Touch-screen) |
| Connection Ports | 1 x RS232, 2 x USB |
| Filters | 405nm, 450nm, 492nm, 630nm |
| Linearity | 0~1.5 A < 1.0% |
| Stability | < 0.005 Abs / 10 min |
| Repeatability | < 1% |
| Wavelength Accuracy | ±2nm |
| Photometric Accuracy | 0~0.2 A 0.001 Abs |
| Certification | CE, ISO |
| Instrument Classification | Class II |
| Language | English |
| Color | White |
| Dimensions (Approx.) | Length: 20cm, Width: 20cm, Height: 20cm |
| Weight (Approx.) | 3.0 kg |
4. Setup
- Unpacking: Carefully remove the MR-96A Elisa Reader from its packaging. Retain all packaging materials for future transport or storage.
- Placement: Place the instrument on a stable, level surface in a clean, dry environment, away from direct sunlight, excessive vibration, and strong electromagnetic fields. Ensure adequate ventilation around the unit.
- Power Connection: Connect the provided power cable to the instrument's power input and then to a grounded electrical outlet.
- Peripheral Connections (Optional): If using external peripherals, connect the mouse, keyboard, or external printer to the available USB ports. For PC control, use the RS232 port.
- Initial Power On: Press the power button to turn on the instrument. Allow the system to initialize completely.

5. Operating Instructions
The MR-96A features a user-friendly touchscreen interface for all operations.
- Navigation: Use the touch pen or your finger to navigate through the menus on the 7.8" LCD touchscreen. A pop-up keypad will appear for data entry when needed.
- Test Setup: From the main menu, select "Test Setup" to configure your assay parameters, including wavelength filters (405nm, 450nm, 492nm, 630nm), shaking modes, and other test-specific settings.
- Running a Test: Once the test parameters are set, load your microplate into the designated slot. Select "Run" from the main menu to initiate the reading process.
- Viewing Reports: After a test is completed, navigate to the "Reports" section to view and analyze the results. The instrument can store up to 20,000 results.
- Printing Results: Use the built-in thermal printer to obtain a hard copy of your reports.
- System Setup: Access "System Setup" for instrument calibration, date/time settings, and other system configurations.
- Shutdown: Always use the "Shutdown" option from the menu before powering off the instrument to ensure proper data saving and system integrity.

6. Maintenance
- Cleaning: Regularly clean the exterior of the instrument with a soft, damp cloth. Avoid using abrasive cleaners or solvents.
- Optical Path: Keep the optical path and microplate reading area free from dust and spills. Use a lint-free cloth and appropriate cleaning solutions as recommended by the manufacturer (if specified in a full manual).
- Printer Maintenance: Ensure the thermal printer paper is replaced when low and keep the printer head clean according to standard thermal printer maintenance procedures.
- Software Updates: Periodically check for any available software updates to ensure optimal performance and access to new features.
- Calibration: Perform regular calibration checks as per laboratory protocols to maintain measurement accuracy.
7. Troubleshooting
- Instrument Not Powering On: Check the power cable connection and ensure the power outlet is functional.
- Touchscreen Unresponsive: Restart the instrument. If the issue persists, ensure the touch pen is being used correctly or try a gentle touch with a clean finger.
- Inaccurate Readings: Verify that the correct filters are selected for the assay. Perform a calibration check. Ensure the microplate is clean and properly seated.
- Printer Not Working: Check if there is enough thermal paper. Ensure the printer mechanism is clear of obstructions.
- Connectivity Issues: For RS232 or USB connections, ensure cables are securely connected and drivers (if required for PC software) are correctly installed.
For persistent issues, please contact technical support.
8. User Tips
- Always use the provided touch pen for precise interaction with the touchscreen, especially for delicate selections.
- Regularly back up your stored test results to an external PC using the RS232 or USB connection to prevent data loss.
- Keep the instrument's software updated to benefit from performance enhancements and new features.
- Ensure microplates are free from dust, scratches, or smudges before loading to guarantee accurate readings.
9. Warranty and Support
The Mindray MR-96A Elisa Reader comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use. Online technical support is available to assist with any operational or technical queries.
Contact Information for Support:
- Telephone: +8618774893330
- E-mail: 535001993@qq.com