1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Daikin BRC944 Series Line Controller Display Panel. Please read this manual thoroughly before using the product and keep it for future reference.

The Daikin BRC944 series are advanced line controller display panels designed for commercial air conditioning systems, offering intuitive control over various functions.

Daikin BRC944C1C control panel, angled view
Figure 1: Daikin BRC944C1C Control Panel (Angled View)

2. Setup and Installation

The Daikin BRC944 series line controller is designed for professional installation. Ensure all power to the air conditioning unit is disconnected before beginning installation.

2.1 Package Contents

Verify that all components are present in the package:

  • Daikin BRC944 Series Display Panel
  • Connection Cables
  • Mounting Screws
  • Accessory Box (may contain additional connectors or components)
  • User Manual (this document)
Daikin BRC944B1C control panel with included wiring and screws
Figure 2: BRC944B1C Panel with Installation Components

2.2 Mounting the Panel

  1. Choose a suitable indoor location for the panel, away from direct sunlight, heat sources, and areas with high humidity.
  2. Ensure there is sufficient space for wiring access behind the panel.
  3. Secure the mounting bracket (if separate) to the wall using the provided screws.
  4. Attach the display panel to the mounting bracket.

2.3 Wiring Connections

Connect the display panel to the indoor unit of the air conditioning system using the provided communication cables. Refer to the wiring diagram specific to your air conditioning unit model for correct terminal connections. Improper wiring can damage the unit or the controller.

Daikin BRC944C1C control panel with wiring and accessory box
Figure 3: BRC944C1C Panel with Wiring for Connection

Warning: All wiring must be performed by a qualified technician in accordance with local electrical codes and regulations.

3. Operating Instructions

The BRC944 series offers intuitive control over your Daikin air conditioning system. The following describes common functions based on the BRC944B1C panel layout.

Daikin BRC944B1C control panel with English button labels and timer diagram
Figure 4: BRC944B1C Control Panel with English Labels

3.1 Basic Controls

  • ON/OFF Button: Press to turn the air conditioning unit on or off.
  • MODE Button: Cycles through operation modes (e.g., Cool, Heat, Fan, Dry, Auto).
  • FAN Button: Adjusts the fan speed (e.g., Low, Medium, High, Auto).
  • UP/DOWN Buttons (TEMP): Adjusts the desired temperature setting.
  • SET Button: Used to confirm selections in menu or timer settings.
  • TIMER Button: Accesses the timer settings for scheduled operation.

3.2 Setting the Timer (BRC944B1C Example)

The BRC944B1C panel includes a diagram for setting the timer. Follow these steps:

  1. One-Time Timer:
    • Press the TIMER button.
    • Use UP/DOWN to set the desired ON or OFF time.
    • Press SET to confirm.
  2. Daily Timer:
    • Press the TIMER button repeatedly until 'DAILY TIMER' is selected.
    • Use UP/DOWN to set the desired ON or OFF time.
    • Press SET to confirm.

The display will show the active timer settings. To cancel a timer, navigate to the timer setting and press the TIMER button until the timer indicator disappears or select 'CANCEL' if available.

4. Maintenance

Regular maintenance ensures optimal performance and longevity of your display panel.

  • Cleaning: Wipe the display panel surface with a soft, dry cloth. For stubborn dirt, use a slightly damp cloth with mild detergent, then wipe dry. Do not use abrasive cleaners, solvents, or chemical sprays directly on the panel.
  • Avoid Moisture: Keep the panel dry and away from water or excessive humidity.
  • Inspection: Periodically check the panel for any physical damage or loose connections.

Caution: Do not attempt to open the display panel housing. Refer all internal servicing to qualified personnel.

5. Troubleshooting

If you encounter issues with your display panel, try the following basic troubleshooting steps:

  • Panel is unresponsive/blank display:
    • Check if the air conditioning unit has power.
    • Ensure all wiring connections are secure.
    • Try cycling the power to the air conditioning unit (turn off at the breaker for a few minutes, then turn back on).
  • Incorrect temperature readings:
    • Ensure the panel is not exposed to direct heat sources or drafts that could affect its internal temperature sensor.
  • Buttons not responding:
    • Gently clean the button area to remove any dust or debris.

If the problem persists after attempting these steps, contact a qualified service technician.

6. Specifications

FeatureDetail
Model NumbersBRC944C1C, BRC944B1C, BRC944A1C
TypeAir Conditioning Fitting / Air Conditioner Parts
ApplicationCommercial
CertificationCE
OriginMainland China
Package Dimensions (L x W x H)18 cm x 18 cm x 6 cm
Package Weight1.0 kg

7. User Tips

  • For optimal energy efficiency, set your desired temperature and allow the system to maintain it rather than frequently adjusting.
  • Familiarize yourself with the different operation modes (Cool, Heat, Fan, Dry) to select the most appropriate one for current conditions.
  • Utilize the timer function to pre-cool or pre-heat your space before arrival, saving energy and enhancing comfort.

8. Warranty and Support

For warranty information, technical support, or service requests, please contact your original point of purchase or an authorized Daikin service center. Keep your purchase receipt and product model information handy when contacting support.

Related Documents - BRC944C1C, BRC944B1C, BRC944A1C

Preview DAIKIN APP 管理员支持手册 BRC1H 系列
DAIKIN APP 管理员支持手册提供了关于有线遥控器 BRC1H 系列的详细操作指南、设置方法和故障排除信息,帮助管理员高效管理和维护 DAIKIN 空调系统。
Preview Daikin Centrifugal Compressor Water Chillers: Product Overview and Specifications
Explore Daikin's range of Centrifugal Compressor Water Chillers, including WSC, WDC, WCC, and HSC models. This document details features, benefits, specifications, and applications for commercial, residential, and industrial HVAC solutions.
Preview Daikin Compact T Air Handling Unit ATB Operating Manual
This operating manual provides comprehensive information on the Daikin Compact T Air Handling Unit (ATB) series, covering system diagnostics, control functions, configuration options, safety information, and operational procedures.
Preview Daikin Residential VRV System Air Conditioner Operation Manual
This operation manual provides essential information for the Daikin Residential VRV System air conditioner, covering installation, operation, maintenance, and troubleshooting for models RXSQ24TAVJUA, RXSQ36TAVJUA, RXSQ48TAVJUA, and RXSQ60TAVJUA.
Preview Daikin FIT for Multi-Family Applications: Efficient & Space-Saving HVAC
Discover the Daikin FIT system, an innovative HVAC solution designed for multi-family buildings. Learn about its energy efficiency, compact design, quiet operation, and smart integration capabilities for optimal comfort.
Preview Daikin Air Conditioning Condensing Unit Installation and Service Reference Manual (IOD-4048D)
Installation and service reference manual for Daikin air conditioning condensing units (model IOD-4048D). Covers safety, installation, electrical, refrigerant, troubleshooting, and maintenance for residential and light commercial applications. Features R-32 refrigerant and various Daikin model series.