JIAYIN JYPDM DC 6V 7.2V 7.4V 5W Micro 370 Motor Water Pump

Contents

JIAYIN JYPDM Micro 370 Motor Water Pump Instruction Manual

Models: A (with cable) & B (without cable)

1. Introduction

This manual provides essential information for the safe and efficient operation, setup, and maintenance of your JIAYIN JYPDM Micro 370 Motor Water Pump. This high-pressure, self-priming electric diaphragm pump is designed for various water transfer applications. Please read this manual thoroughly before use.

2. Safety Information

Always observe the following safety precautions to prevent injury or damage to the pump:

  • Ensure the power supply voltage matches the pump's rated voltage (DC 3.7V-7.4V).
  • Do not operate the pump with damaged wiring.
  • Avoid submerging the motor part of the pump in water.
  • Keep hands and loose clothing away from moving parts during operation.
  • Disconnect power before performing any maintenance or installation.
  • This pump is designed for water usage. Do not use with flammable, corrosive, or highly viscous liquids.

3. Product Overview

The JIAYIN JYPDM Micro 370 Motor Water Pump is a compact, high-pressure diaphragm pump. It is available in two main versions:

  • Version A: Pump with pre-attached power cables (red and black).
  • Version B: Pump without pre-attached power cables.
Two versions of the JIAYIN Micro Water Pump (A with cable, B without cable).
Figure 1: Two versions of the JIAYIN Micro Water Pump (A with cable, B without cable).
JIAYIN Micro Water Pump, Version A, with pre-attached power cables.
Figure 2: JIAYIN Micro Water Pump, Version A, with pre-attached power cables.
JIAYIN Micro Water Pump, Version B, without pre-attached power cables.
Figure 3: JIAYIN Micro Water Pump, Version B, without pre-attached power cables.
Dimensions of the JIAYIN Micro Water Pump, showing length (62mm), height (27mm), and width (12mm).
Figure 4: Dimensions of the JIAYIN Micro Water Pump (approx. 62mm length, 27mm height, 12mm width).
Top view of the JIAYIN Micro Water Pump, showing inlet and outlet ports.
Figure 5: Top view of the JIAYIN Micro Water Pump, showing inlet and outlet ports.

4. Specifications

Feature Detail
Model 370 micro water pump
Voltage Range DC 3.7V - 7.4V
Rated Voltage 7.2V
No Load Current 250mA
Power 5W (Electric)
Structure Diaphragm Pump
Pressure High Pressure
Usage Water
Motor Type 370 carbon brush motor
Dimensions (Approx.) Length: 62mm, Height: 27mm, Width: 12mm
Origin China Mainland
Certification None
High-concerned chemical None

5. Setup Instructions

5.1 Mounting

The pump features integrated mounting tabs on its body. Secure the pump using appropriate screws or fasteners through these tabs to a stable surface. Ensure the pump is mounted in a position that allows for easy access and proper tubing connections.

Side view of two JIAYIN Micro Water Pumps, highlighting the mounting tabs.
Figure 6: Side view of the pump, showing mounting tabs.

5.2 Tubing Connection

  1. Identify the inlet and outlet ports on the top of the pump (refer to Figure 5).
  2. Connect appropriate tubing to both the inlet and outlet ports. Ensure a snug fit to prevent leaks.
  3. For self-priming operation, ensure the inlet tubing is submerged in the liquid source.

5.3 Electrical Connection

For Version A (with cable):

  • Connect the red wire to the positive (+) terminal of your DC power supply.
  • Connect the black wire to the negative (-) terminal of your DC power supply.

For Version B (without cable):

  • Carefully solder or connect your own power wires to the motor terminals, observing correct polarity (positive and negative).
  • Ensure all electrical connections are secure and insulated to prevent short circuits.

WARNING: Incorrect polarity may damage the pump. Always verify connections before applying power.

6. Operating Instructions

  1. Ensure all tubing connections are secure and the inlet tube is properly positioned in the liquid source.
  2. Verify that the power supply is set to the correct voltage (within DC 3.7V-7.4V).
  3. Apply power to the pump. The pump should start operating, drawing liquid through the inlet and expelling it through the outlet.
  4. Monitor the pump during initial operation for any leaks or unusual noises.
  5. To stop operation, disconnect the power supply.

6.1 Self-Priming Function

This pump is self-priming, meaning it can draw liquid from a level below itself without needing to be pre-filled. However, for optimal performance and longevity, it is recommended to minimize the vertical lift distance for the inlet.

7. Maintenance

  • Regular Inspection: Periodically check tubing for kinks, blockages, or wear. Inspect electrical connections for corrosion or damage.
  • Cleaning: If the pump's performance degrades, it may be due to internal blockages. Disconnect power and tubing, then flush the pump with clean water. Do not use harsh chemicals.
  • Storage: If storing the pump for an extended period, ensure it is clean and dry.
  • Surface Scratches: Please note that some pumps may have minor surface scratches due to shipping. These do not affect the pump's functionality or performance.

8. Troubleshooting

Problem Possible Cause Solution
Pump does not start
  • No power or incorrect voltage
  • Incorrect wiring polarity
  • Motor fault
  • Check power supply and voltage.
  • Verify wiring polarity (red to +, black to -).
  • Contact support if motor is faulty.
Low or no flow
  • Inlet/outlet blocked
  • Air leak in inlet tubing
  • Pump not primed (for non-self-priming setups, though this model is self-priming)
  • Check and clear any blockages in tubing or pump ports.
  • Ensure all tubing connections are airtight.
  • Ensure inlet tubing is fully submerged.
Excessive noise
  • Air in the system
  • Loose mounting
  • Internal wear
  • Check for air leaks in inlet.
  • Securely mount the pump.
  • If persistent, internal wear may be present.

9. User Tips

  • For continuous operation, ensure adequate cooling for the motor, especially at higher voltages.
  • Consider adding a small filter to the inlet line to prevent debris from entering and damaging the pump.
  • When using with batteries, ensure the battery can provide sufficient current (250mA or more) for stable operation.
  • If using for DIY projects, always test the setup with water before integrating into a final system.

10. Warranty and Support

For any questions, technical assistance, or warranty claims, please contact the seller or manufacturer directly. Provide your purchase details and a clear description of the issue for prompt support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.