ezyopenteck EG-22A

EG-22A(EGA-10) 24V PCB Control Board User Manual

For Automatic Double Arms Swing Gate Openers

Brand: ezyopenteck | Model: EG-22A (EGA-10)

1. Introduction

The EG-22A (also known as EGA-10) is a 24V PCB control board designed for automatic double arms swing gate openers. This smart control center system is compatible with all EZYOPENTECK and GIANT JUJIANG swing gate openers. It offers advanced features for controlling your gate system, including support for wireless keypads, alarm lights, and infrared sensors, while ensuring encrypted safety for your security and privacy.

EG-22A control board with compatibility text
Figure 1: EG-22A Control Board and its compatibility with EZYOPENTECK and GIANT JUJIANG swing gate openers.

2. Setup and Installation

The EG-22A control board is designed for easy installation. Follow these steps to connect and calibrate it with your existing gate opener system.

2.1 Component Identification

Before installation, familiarize yourself with the key components and connection points on the control board.

Labeled diagram of EG-22A control board components
Figure 2: Labeled diagram of the EG-22A control board showing key components and ports.
  • Power Port: For connecting the main power supply.
  • Function Setting / Digital Tube Display: Used for easy and accurate DIY function settings.
  • Function Setting Key: Buttons for navigating and adjusting settings.
  • Learning Code Key: For pairing remote controls.
  • Multifunctional External Port: For connecting various external devices.
  • Motor Connections (MOTOR1, MOTOR2): For connecting the gate opener motors.

2.2 Wiring Diagram

Refer to the detailed PCB wiring diagram for precise connections of power, motors, and external accessories.

Detailed PCB wiring diagram for EG-22A control board
Figure 3: Detailed PCB wiring diagram for the EG-22A control board.

Key Connection Points:

  • AC24V: Main power input.
  • GND: Ground connections.
  • MOTOR1 / MOTOR2: Connect your swing gate motors here.
  • 2SIDE / 1SIDE / COM: Connections for various gate control inputs.
  • SWIPE CARD: For card reader integration.
  • IR: For infrared sensor connection.
  • 12V / 24U BATT: Auxiliary power outputs.
  • LAMP: For connecting an alarm light.
  • LOCK NF / LOCK NA: For electric lock connections.
  • SP: Speaker output (if applicable).

Ensure all connections are secure and correctly aligned according to the diagram. Incorrect wiring can damage the board or connected devices.

2.3 Remote Control Pairing

To pair remote controls with the EG-22A board:

  1. Press the 'LEARN' button (Learning code key) on the control board.
  2. While the indicator light is active, press the desired button on your remote control.
  3. The indicator light will flash or change state to confirm successful pairing.
  4. Repeat for additional remote controls.

3. Operating Instructions

Once installed, the EG-22A control board allows for precise control and customization of your swing gate opener.

3.1 Basic Operation

Operate your gate using the paired remote controls. Pressing the assigned button will initiate the gate opening or closing sequence.

3.2 Function Customization

The digital tube display and function setting keys allow for various customizations. Specific functions may include:

  • Adjusting opening/closing times.
  • Setting auto-close delays.
  • Configuring safety features with infrared sensors.
  • Integrating wireless keypads for access control.

Refer to the on-screen prompts on the digital tube display and use the function setting keys to navigate and modify these parameters.

4. Maintenance

To ensure optimal performance and longevity of your EG-22A control board, consider the following maintenance tips:

  • Keep Clean: Periodically inspect the board for dust or debris and gently clean with a soft, dry brush.
  • Check Connections: Ensure all wiring connections remain secure and free from corrosion.
  • Environmental Protection: Ensure the control board is housed in a protective enclosure to shield it from moisture, extreme temperatures, and pests.

5. Troubleshooting

If you encounter issues with your EG-22A control board, consider these basic troubleshooting steps:

  • No Power: Check the main power supply connection to the AC24V port. Ensure the power source is active.
  • Gate Not Responding: Verify that all motor connections (MOTOR1, MOTOR2) are secure. Check if remote controls are properly paired (refer to Section 2.3).
  • Erratic Behavior: Inspect all external device connections (infrared sensors, keypads) for proper wiring and functionality.
  • Remote Control Issues: If a remote control stops working, try re-pairing it. Ensure the remote's battery is not depleted.

For complex issues, it is recommended to contact technical support.

6. Specifications

AttributeSpecification
Model NumberEG-22A (EGA-10)
Brand Nameezyopenteck
Product NameSwing gate control board
FunctionSwing gate opener motor control
VoltageDC 24V
Output VoltageDC 24V
Protection Fuse10A
Frequency433.92Mhz Rolling code
Use for12/24V swing gate motor
Universal CompatibilityGiant, JUJIANG, EZYOPENTECK and similar
Package Length20 cm
Package Width15 cm
Package Height4 cm
Package Weight0.4 kg

7. Warranty and Support

Ezyopenteck is committed to providing professional service and support for its products.

7.1 Contact Support

For any problems or inquiries regarding your EG-22A control board, please contact ezyopenteck directly. They are specialized in designing and producing smart gate automation systems and access control solutions.

Email: ezyopenteck@outlook.com

It is recommended to contact support before attempting complex repairs or modifications.

8. User Tips

  • Voltage Compatibility: The EG-22A board is specifically designed for 24V motors. Ensure your gate opener motors are compatible with a DC 24V system.
  • Remote Control Frequency: If purchasing the control board separately, it is crucial to confirm the compatibility and frequency of your existing remote controls with the EG-22A board. Frequencies can vary by region (e.g., Russia, Poland, Spain, Australia, Germany). Contact ezyopenteck support to verify compatibility to avoid issues.
  • Calibration: After installation, perform a calibration of the gate opener system to ensure smooth and correct operation of the gate arms.

Related Documents - EG-22A

Preview Universal PCB Experiment Board: Usage Guide and Overview
Learn how to use and handle universal PCB prototype boards for DIY electronics, teaching, and circuit verification. Includes safety warnings and fixing methods.
Preview AC 220V Swing Gate Opener User Manual
Comprehensive user manual for the AC 220V Swing Gate Opener, detailing installation, safety precautions, technical specifications, control board instructions, remote control setup, and smart module integration.
Preview PCB Board for Double/Single-Sided Adapters - Safety and Usage Guide
Essential safety rules, key warnings, and usage guidelines for PCB boards, suitable for educational and DIY projects. Learn about proper handling, assembly, and disclaimer information.
Preview PKM-C03 Swing Gate Opener Installation Manual: Solar & Electric Systems
Comprehensive installation manual for the PKM-C03 automatic swing gate opener. Covers setup, technical specifications, safety guidelines, and operation for solar or electric systems.
Preview PowerFlex 4 Adjustable Frequency AC Drive Product Information
Technical specifications, mounting guidelines, wiring diagrams, and start-up procedures for the Rockwell Automation PowerFlex 4 Adjustable Frequency AC Drive (Catalog Number 22A).
Preview Elecrow Regular Custom PCB Specification and FAQ
Comprehensive guide to Elecrow's Regular Custom PCB services, covering specifications, frequently asked questions, comparisons with Premium PCB, and technical details for PCB manufacturing.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.