1. Introduction and Overview
The SKE PH21-3.6K is a high-performance Pure Sine Wave Hybrid Solar Inverter designed for household solar power generation systems. It integrates a solar charger and AC charger, offering versatile power management for various applications. This inverter is capable of working with or without a battery, providing flexibility for your energy needs. It features a wide PV input voltage range and robust protection mechanisms to ensure reliable operation.

2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- High Voltage Warning: This device operates with high voltages. Only qualified personnel should perform installation and maintenance.
- Ensure proper grounding of the inverter.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from water, excessive heat, and flammable materials.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect all power sources (AC, PV, and Battery) before performing any maintenance or wiring.
- Use appropriate personal protective equipment (PPE) during installation.

3. Product Features
- Pure Sine Wave Output: Provides clean and stable power suitable for sensitive electronics.
- Wide PV Input Voltage Range: Supports 60-500VDC from solar panels.
- Selectable AC/Solar Input Charging Current: Allows customization of charging sources.
- Comprehensive Protection: Includes overload, short circuit, and overvoltage protection.
- Cold Start Function: Enables the inverter to start directly from batteries without AC input.
- Built-in Anti-Dust Kit: Designed for enhanced durability in harsh environments.
- Flexible Operation: Can operate with or without a battery.
- Configurable Power Source: Compatible with mains voltage or generator power.
- Smart Battery Charger Design: Optimizes battery performance and longevity.
- Dual Communication Ports: Equipped with ports for battery management system (BMS) and WiFi (optional).
- High Efficiency: Peak efficiency of 93%.
- Application: Ideal for household solar power generation systems.
4. Product Components and Appearance
The SKE PH21-3.6K inverter features a user-friendly design with clearly labeled components. Refer to the diagram below for an overview of the inverter's parts:

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons (ENTER, DOWN, UP, ESC)
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- Circuit breaker
- RS485 for BMS communication
- Antenna (for optional WiFi module)
5. Specifications
| Feature | Specification (PH21-3.6K) |
|---|---|
| Rated Power | 3600VA / 3600W |
| Input Voltage | 230 VAC |
| Selectable Input Voltage Range | 170-280VAC (for Personal Computers); 90-280VAC (for Home Appliances) |
| Frequency Range | 50 Hz / 60 Hz (Auto sensing) |
| AC Voltage Regulation (Battery Mode) | 230VAC ± 5% |
| Peak Power | 7200VA |
| Efficiency (Peak) | 93% |
| Transfer Time | 10 ms (for Personal Computers); 20 ms (for Home Appliances) |
| Waveform | Pure sine wave |
| Battery Voltage | 24 VDC |
| Floating Charge Voltage | 27 VDC |
| Overcharge Protection | 29.2 VDC (Corrected from source's 329.2 VDC, which is likely a typo for a 24V system) |
| Solar Charger Type | MPPT |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Maximum PV Array Power | 4000 W |
| MPP Range Operating Voltage | 60~450 VDC |
| Maximum Solar Charge Current | 80 A |
| Maximum AC Charge Current | 80 A |
| Maximum Charge Current | 80 A |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Operating Temperature | 0℃ to 50℃ |
| Storage Temperature | -15℃ to 60℃ |
| Dimensions (DxWxH) | 334 x 309 x 109 mm |
| Net Weight | 8.3 kg |
| Communication Interface | USB/RS232 |
| Certification | CE |
| DIY Supplies Category | Electrical |
| Origin | Mainland China, Guangdong |
6. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your SKE PH21-3.6K Hybrid Solar Inverter. Please follow the wiring diagram and instructions carefully. It is recommended that installation be performed by a certified electrician.
6.1 System Connection Diagram

6.2 Connection Steps
- Mounting: Securely mount the inverter in a well-ventilated area, away from direct sunlight, moisture, and heat sources. Ensure sufficient clearance for airflow around the unit.
- Battery Connection: Connect the battery bank to the BAT+ and BAT- terminals on the inverter. Ensure correct polarity. The PH21-3.6K requires a 24VDC battery system.
- PV Input Connection: Connect the solar panels to the PV IN+ and PV IN- terminals. Verify that the PV array's open circuit voltage and power are within the inverter's specified limits (Max 500 VDC, Max 4000 W).
- AC Input Connection: Connect the AC utility grid or generator to the AC IN terminals (L, N, G).
- AC Output Connection: Connect your household loads or distribution panel to the AC OUT terminals (L, N, G).
- Communication Connections (Optional): If using, connect the RS232/USB cable for monitoring or install the optional WiFi module for remote access.
- Power On: Once all connections are secure and verified, switch on the circuit breaker (if installed), then turn on the inverter's power switch.
Applicable Appliances: The inverter can power a wide range of household appliances, including digital products, projectors, hot water bottles, refrigerators, laptops, electric cookers, air-conditioning units, soymilk machines, impact drills, fans, air ducts, submersible pumps, LED lights, hand drills, desktop PCs, CRT TVs, vacuum cleaners, printers, hand mills, and dryers.
7. Operating Instructions
The inverter features an LCD display and function buttons for monitoring and configuration.
7.1 LCD Display and Indicators
- LCD Display: Shows real-time system status, input/output voltages, battery charge level, and error codes.
- Status Indicator: Illuminates to indicate normal operation.
- Charging Indicator: Shows the charging status of the battery.
- Fault Indicator: Illuminates to indicate a system fault or error.
7.2 Function Buttons
- ENTER: Confirms selections or enters menu options.
- DOWN: Navigates down through menu options or decreases values.
- UP: Navigates up through menu options or increases values.
- ESC: Exits current menu or cancels an operation.
Refer to the detailed operating manual (if available from the manufacturer) for specific menu navigation and parameter settings.
8. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter and ensure that the cooling vents are free from dust and debris. The built-in anti-dust kit helps, but regular checks are still recommended, especially in harsh environments.
- Connections: Annually inspect all electrical connections (PV, battery, AC input/output) for tightness and corrosion. Tighten any loose connections.
- Battery Health: Monitor battery voltage and performance regularly. Follow the battery manufacturer's maintenance guidelines.
- Environment: Ensure the installation environment remains within the specified temperature and humidity ranges.
9. Troubleshooting
The inverter is equipped with protection features that may trigger a fault indicator. Here are some common issues and potential solutions:
- Overload Protection: If the fault indicator lights up due to an overload, disconnect some loads from the inverter output. The inverter will attempt to restart after a short period. Ensure the total load does not exceed the inverter's rated power (3600W) or peak power (7200VA).
- Short Circuit Protection: If a short circuit occurs at the output, the inverter will shut down to protect itself. Identify and resolve the short circuit issue in your wiring or connected appliances before restarting the inverter.
- Overvoltage Protection: If the input voltage (AC or PV) exceeds safe limits, the inverter will activate overvoltage protection. Check the input voltage sources to ensure they are within the specified operating range.
- No Output Power: Check the AC input, PV input, and battery connections. Ensure the inverter is powered on and no fault indicators are active. Verify battery voltage is sufficient.
- Inverter Not Charging Battery: Check PV input connections and voltage. Ensure the solar charger type (MPPT) is correctly configured if applicable. Verify AC input is present if AC charging is desired.
For persistent issues, consult a qualified technician or contact customer support.
10. Warranty and Support
The SKE PH21-3.6K Hybrid Solar Inverter comes with a 2-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
The warranty does not cover:
- Damage caused by improper installation or operation.
- Damage caused by unauthorized modifications or repairs.
- Damage caused by natural disasters or external factors.
- Normal wear and tear.
For warranty claims or technical support, please contact your retailer or the manufacturer directly. Provide your product model number (PH21-3.6K) and proof of purchase when seeking support.