HITACHI PSC-A64S

HITACHI PSC-A64S Air Conditioning Central Control Unit User Manual

Model: PSC-A64S

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of the HITACHI PSC-A64S Central Control Unit for commercial air conditioning systems. Please read this manual thoroughly before using the product and keep it for future reference.

2. Safety Information

  • Professional Installation: Installation and wiring must be performed by qualified and licensed HVAC technicians in accordance with all local and national electrical codes.
  • Power Supply: Ensure the power supply matches the unit's requirements (AC220-240V) and that proper grounding is established.
  • Electrical Hazard: Do not open the unit or attempt repairs yourself. High voltage is present and can cause severe injury or death. Disconnect power before any servicing.
  • Environmental Conditions: Do not expose the unit to water, excessive humidity, or extreme temperatures.

3. Product Overview

The HITACHI PSC-A64S is a central control unit designed for commercial air conditioning applications. It features a clear LCD display and intuitive buttons for managing various air conditioning functions.

3.1 Front Panel

The front panel includes the main display and control buttons. The flap can be opened to reveal additional function buttons.

Front view of the HITACHI PSC-A64S control unit with flap closed

Figure 1: Front view of the control unit (flap closed)

Front view of the HITACHI PSC-A64S control unit with flap open, showing additional buttons

Figure 2: Front view of the control unit (flap open)

3.2 Rear Panel and Connections

The rear panel houses the electrical connections for power, communication, and external inputs/outputs.

Rear view of the HITACHI PSC-A64S control unit showing wiring terminals

Figure 3: Rear view with wiring terminals

3.3 Product Video Overview

Video 1: A brief visual overview of the HITACHI PSC-A64S Central Control Unit.

4. Specifications

AttributeValue
Model NumberPSC-A64S
Brand NameHITACHI
Product Size118.6*118.6*70 mm
Single Package Size17.2*12*17 cm
ColorWhite
PackagingCarton Box
TypeAir Conditioning Fitting
OriginMainland China
Power SourceElectric
ApplicationCommercial
Net Weight (N.W.)0.32KG
Gross Weight (G.W.)0.6kg

5. Setup and Installation

Installation of the PSC-A64S Central Control Unit requires specialized knowledge and should only be performed by certified professionals to ensure safety and proper functionality.

5.1 Wiring Connections

Refer to the diagram on the rear panel of the unit for correct wiring. Key connection points include:

  • TB1 MAIN POWER: Connect AC220-240V power supply. Ensure proper EARTH connection.
  • TB2 H-LINK CONNECTION: For communication with other HITACHI H-LINK compatible devices.
  • CN1, CN2, CN3 TIMER INPUT OUTPUT: These terminals are for timer-related input and output signals. Consult your system's overall wiring diagram for specific usage.

Always ensure power is disconnected before making or breaking any electrical connections.

6. Operation

The control unit features a main display and several buttons for controlling the air conditioning system. The primary buttons are visible, while additional settings are accessible by opening the front flap.

6.1 Basic Controls (Flap Closed)

  • 运行/停止 (Run/Stop): Press to turn the air conditioning unit ON or OFF.
  • 机组 (Unit): Used to select or cycle through different indoor units or groups of units connected to the central controller.
  • Up/Down Arrows (V/Λ): Typically used to adjust settings such as temperature or navigate menu options.

6.2 Advanced Controls (Flap Open)

Opening the front flap reveals additional buttons for more detailed control:

  • 模式 (Mode): Selects the operating mode (e.g., Cool, Heat, Fan, Dry, Auto).
  • 风速 (Fan Speed): Adjusts the fan speed (e.g., Low, Medium, High, Auto).
  • 区域 (Zone): Manages settings for specific zones or areas if the system supports multi-zone control.
  • 复位 (Reset): Resets certain settings or clears error indicators.
  • 定时 (Timer): Sets ON/OFF timers for scheduled operation.
  • 遥控器禁止 (Remote Control Disable): Disables or enables control from other remote controllers.
  • 摆风 (Swing): Controls the louver swing function for air distribution.
  • 设定温度 (Set Temperature): Fine-tunes the desired temperature setting.
  • 点检 (Inspection): Initiates a system inspection or diagnostic check.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your control unit.

  • Cleaning: Wipe the surface of the control unit with a soft, dry cloth. Do not use abrasive cleaners, solvents, or water directly on the unit.
  • Inspection: Periodically check for any visible damage to the unit or its wiring. If any damage is found, contact a qualified technician immediately.
  • Professional Check-ups: It is recommended to have the entire air conditioning system, including the control unit, inspected by a professional HVAC technician annually.

8. Troubleshooting

If you encounter issues with your PSC-A64S control unit, consider the following general troubleshooting steps:

  • No Power/Display: Check the main power supply to the unit and ensure all connections are secure. Verify the circuit breaker has not tripped.
  • Unit Not Responding: Ensure the correct unit or zone is selected. Try pressing the 'Reset' button if available.
  • Error Codes: If an error code appears on the display, consult your air conditioning system's main manual or contact a service professional, providing the specific error code.
  • Intermittent Operation: Check for loose wiring connections or external interference.

For complex issues or if troubleshooting steps do not resolve the problem, contact a qualified service technician.

9. User Tips

  • Professional Consultation: For any technical questions regarding installation, compatibility, or advanced operation, it is highly recommended to consult with a professional technical team.
  • System Compatibility: Ensure the PSC-A64S is compatible with your specific HITACHI commercial air conditioning system before installation.

10. Warranty and Support

10.1 Warranty Information

The structured product data indicates 'None' for warranty. However, the seller's company profile states an 'After-sales service commitment, warranty for one year'. Please clarify warranty terms directly with your supplier or installer.

10.2 Technical Support

For technical support or inquiries, you may contact the seller or a qualified HVAC professional. When contacting support, please provide the brand name, model number (PSC-A64S), and a detailed description of your issue.

Email: zhouxingkeji@aliyun.com

Related Documents - PSC-A64S

Preview Hitachi PSC-A32MN Touchscreen Central Controller Installation and Dimensions
This document provides installation space guidelines and dimensional data for the Hitachi PSC-A32MN Touchscreen Central Controller, a component for HVAC systems.
Preview Hitachi Air Conditioner Management System Central Station DX Operation Manual (PSC-AS2048WXB)
Operation manual for the HITACHI Air Conditioner Managing System Central Station DX Management Software (PSC-AS2048WXB). Covers system configuration, operation ratio calculation, data display, maintenance, and troubleshooting for air conditioning management.
Preview Manual de Instalação e Manutenção Hitachi PSC-A32MN - Controle Central de Ar Condicionado
Guia completo para instalação e manutenção da Estação Central Hitachi PSC-A32MN. Este controlador avançado gerencia até 160 unidades internas e 32 grupos de controle remoto, oferecendo especificações técnicas, procedimentos de fiação, configuração e segurança para sistemas de ar condicionado.
Preview Hitachi YUTAMPO Series Indoor Unit TAW-(190/270)RHC: Návod k instalaci a obsluze
Komplexní průvodce instalací a provozem vnitřních jednotek Hitachi YUTAMPO Series (TAW-190/270RHC). Obsahuje bezpečnostní pokyny, postupy instalace, elektrické zapojení a návod k obsluze pro efektivní vytápění a chlazení.
Preview Hitachi Split Unit Air Conditioner Installation Manual (RAK-VJ50/60/70PHAT)
Comprehensive installation guide for Hitachi RAK-VJ50PHAT, RAK-VJ60PHAT, and RAK-VJ70PHAT split unit air conditioners, covering safety precautions, tools, and step-by-step installation procedures for indoor units.
Preview Hitachi PSC-6RAD RAC-Adapter Installationsanleitung
Detaillierte Installationsanleitung für den Hitachi PSC-6RAD RAC-Adapter, ein Steuerungszubehör für Klimaanlagen. Erfahren Sie, wie Sie diese Komponente sicher und korrekt installieren.