SmartGen HAT700B

Contents

SmartGen HAT700B Dual Power Automatic Switching Controller

Model: HAT700B | Brand: SmartGen

1. Overview

The HAT700 series ATS controller is an intelligent dual-supply module designed for automatic measurement and control in power systems. It features configurable functions, an LCD display, and digital communication capabilities, integrating digital, intelligence, and networking technologies. This controller is an ideal solution for Automatic Transfer Switch (ATS) applications, aiming to reduce incorrect operations through automatic measurement and control.

Equipped with a powerful microprocessor, the unit provides precise voltage measurement for 2-way, 3-phase systems and makes accurate judgments. Its digital output port activates upon detecting abnormal conditions such as over/under voltage, over/under frequency, or loss of phase. This controller has full consideration for various ATS applications (automatic transfer system) and can be directly used for PC ATS, CB ATS, CC ATS, etc. It boasts a compact structure, advanced circuitry, simple wiring, and high reliability, making it suitable for a wide range of applications including electrical devices, automatic control and testing systems for electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, and intelligent building systems.

1.1 Naming Information

The model naming convention provides insight into the controller's features:

Naming Conventions for HAT700 series ATS controllers

Figure 1: Naming Conventions for HAT700 series ATS controllers. The diagram illustrates that HAT700 is the series number, with suffixes B for AC Power, I for Current Sensing, and S for Sync Switch.

2. Specifications

The following table details the performance parameters and general specifications for the HAT700B controller:

ItemParameter
Operating VoltageDC 8.0V~35.0V (continuous power supply)
AC 90V~280V (L1N1/L2N2 for HAT700B/HAT700BI/HAT700S)
Power Consumption<5W (Standby mode: <2W)
AC SystemHAT700/HAT700I, HAT700S
AC Voltage Input (3P4W L-L)80~625V
AC Voltage Input (3P3W L-L)80~625V
AC Voltage Input (1P2W L-N)50~360V
AC Voltage Input (2P3W L-N)80~480V
Rated Frequency50/60Hz
Close Relay Output16A AC250V Volts free output
Auxiliary Relay Output16A/7A AC250V Volts free output
Digital InputGND (B-) connect is active.
CommunicationRS485 isolated interface, MODBUS Protocol
Case Dimensions197mm x 152mm x 47mm
Panel Cutout186mm x 141mm
Working Temperature-25°C to +70°C
Working Humidity20% to 93%RH
Storage Temperature-20°C to +70°C
Protection LevelIP55 (when waterproof gasket ring inserted between panel and housing)
Insulation StrengthApply AC2.2KV voltage between high voltage terminal and low voltage terminal; leakage current is not more than 3.5mA within 1 minute.
WeightHAT700/HAT700I: 0.7kg; HAT700B/HAT700BI/HAT700S: 0.8kg

3. Setup and Installation

Proper installation is crucial for the safe and reliable operation of the HAT700B controller. This section provides guidance on mounting and wiring.

3.1 Mounting

The controller is designed for panel mounting. Ensure the panel cutout dimensions are adhered to for a secure fit. The protection level of IP55 is achieved when a waterproof gasket ring is properly inserted between the panel and the controller housing.

  • Panel Cutout Dimensions: 186mm x 141mm
  • Case Dimensions: 197mm x 152mm x 47mm
Front view of HAT700B controller with mounting brackets

Figure 2: Front view of the HAT700B controller, illustrating its physical appearance and the included mounting brackets for panel installation.

3.2 Wiring Diagram

The HAT700B controller features a comprehensive set of terminals for connecting to power sources, loads, auxiliary inputs/outputs, and communication interfaces. Refer to the detailed wiring diagram below for correct connections. It is highly recommended that installation and wiring be performed by qualified personnel.

Detailed rear wiring diagram for HAT700B ATS Controller

Figure 3: Rear view of the HAT700B controller showing terminal blocks for power inputs, outputs, auxiliary connections, and RS485 communication. Key terminals include S1/S2 Close/Open Outputs, Auxiliary Outputs, AC Voltage Inputs (S1 and S2), Digital Inputs, and Load Current inputs.

Key Wiring Considerations:

  • Power Supply: Connect DC 8.0V~35.0V to the appropriate terminals.
  • AC Voltage Inputs: Connect Source 1 (S1) and Source 2 (S2) AC voltage inputs to terminals 11-14 and 15-18 respectively, ensuring correct phase and neutral connections (A1, B1, C1, N1 for S1; A2, B2, C2, N2 for S2).
  • Relay Outputs: S1 Close/Open outputs (1-4) and S2 Close/Open outputs (15-18) are 16A AC250V volts-free. Auxiliary outputs (5-10) are 16A/7A AC250V volts-free.
  • Digital Inputs: Terminals 19-34 are for digital inputs, where GND (B-) connection is active.
  • Load Current: Connect load current transformers to terminals 35-40 (IA In, IB In, IC In, IA Out, IB Out, IC Out).
  • Communication: RS485 isolated interface terminals (41-43) for MODBUS Protocol (A+, B-, SCR).
  • Grounding: Ensure proper grounding for safety and optimal performance.

4. Operating Instructions

The HAT700B controller features an intuitive front panel with an LCD display, buttons, and indicator lights for easy operation and monitoring.

4.1 Panel Layout and Controls

Front panel layout of HAT700B ATS Controller with buttons and display

Figure 4: Front panel of the HAT700B controller, illustrating the LCD display, navigation buttons (Up/Increase, Down/Decrease, OK, Menu/Esc), and function buttons (Manual, Auto, Start Genset, Lamp Test, Alarm Reset).

4.2 Indicator Lights Description

The controller's indicator lights provide visual feedback on its status and operational modes:

Indicator TypeDescription
AlarmSlow flashing (1 time per sec) when a warning alarm occurs. Fast flashing (5 times per sec) when a fault alarm occurs.
RunningFlashes when the module is counting down (1 time per sec).
S1 Power NormalLit when S1 is normal; flashes when S1 is abnormal (1 time per sec); off when there is no S1 power.
S1 Close StatusLit when S1 close input is activated.
S2 Power NormalLit when S2 is normal; flashes when S2 is abnormal (1 time per sec); off when there is no S2 power.
S2 Close StatusLit when S2 close input is activated.
Manual ModeLit when the module is in Manual mode.
Auto ModeLit when the module is in Auto mode.
Generator StartLit when the Start signal is initiated.

Figure 5: Table describing the meaning of each indicator light on the HAT700B controller panel.

4.3 Basic Operation Modes

  • Manual Mode: Press the "Manual" button to enter manual operation. In this mode, you can manually control the generator start/stop and transfer switches.
  • Auto Mode: Press the "Auto" button to enable automatic operation. The controller will automatically monitor power sources and perform transfers as configured.
  • Start Genset: In Manual mode, this button can be used to manually start the generator.
  • Lamp Test: Press this button to test all indicator lights on the panel.
  • Alarm Reset: Press this button to acknowledge and reset active alarms.
  • Menu/Esc: Used to navigate through menus and exit current screens.
  • Up/Increase & Down/Decrease: Used for navigation and adjusting parameter values within menus.
  • OK: Confirms selections or enters sub-menus.

5. Maintenance

To ensure the longevity and reliable performance of your HAT700B controller, regular maintenance is recommended.

  • Regular Inspection: Periodically check all wiring connections for tightness and signs of corrosion.
  • Cleaning: Keep the controller's front panel clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using abrasive cleaners or solvents.
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges (-25°C to +70°C, 20% to 93%RH) to prevent damage.
  • Firmware Updates: Check with the manufacturer or supplier for any available firmware updates that may improve performance or add features.

6. Troubleshooting

This section provides general guidance for common issues. For complex problems, it is recommended to consult a qualified technician or contact customer support.

  • Controller Not Powering On:
    • Check the DC power supply connections (8.0V~35.0V) to ensure they are secure and providing the correct voltage.
    • Verify that the power source itself is operational.
  • No AC Voltage Reading:
    • Inspect the AC voltage input wiring for both Source 1 and Source 2 (terminals 11-18).
    • Ensure the AC power sources are active and within the specified voltage range.
  • Alarms Triggering Frequently:
    • Refer to the "Indicator Lights Description" (Table 5) to identify the specific alarm type (warning or fault).
    • Investigate the cause of the alarm based on the indicator's behavior (e.g., S1/S2 Power Normal flashing indicates an abnormal power source).
    • Press the "Alarm Reset" button after resolving the issue.
  • Automatic Transfer Not Occurring:
    • Ensure the controller is in "Auto Mode" (Auto indicator lit).
    • Verify that both power sources (S1 and S2) are correctly connected and their status is being detected by the controller.
    • Check the configuration settings for transfer parameters (e.g., voltage thresholds, delay times).

7. User Tips

  • Professional Installation: For optimal safety and performance, always have the HAT700B controller installed and wired by a certified electrician or qualified technician.
  • Regular Monitoring: Periodically check the LCD display and indicator lights to ensure the system is operating as expected and to catch any potential issues early.
  • Backup Power Testing: Regularly test your generator and ATS system to ensure it functions correctly during a power outage.
  • Documentation: Keep this manual and any system-specific wiring diagrams readily accessible for future reference.

8. Warranty and Support

For warranty information, technical support, or any inquiries regarding your SmartGen HAT700B controller, please contact the seller or manufacturer directly.

Seller: Epower Diesel Genset Part Store

Contact Information:

  • WeChat/WhatsApp: +8615359712778
  • Email: fuanyizhiyuan@gmail.com
  • Website: www.epowerge.com

Please provide your product model (HAT700B) and any relevant purchase details when contacting support to facilitate a quicker resolution.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.