HOMCOM 821-010V70WT

Contents

HOMCOM 12L/Day Dehumidifier User Manual

Model: 821-010V70WT

1. Introduction

Thank you for choosing the HOMCOM 12L/Day Dehumidifier. This appliance is designed to efficiently remove excess moisture from the air, creating a more comfortable and healthy indoor environment. Please read this manual thoroughly before operating the unit and retain it for future reference.

HOMCOM 12L/Day Dehumidifier, front view
Figure 1: HOMCOM 12L/Day Dehumidifier

This image shows the HOMCOM 12L/Day Dehumidifier from the front, highlighting its compact and modern design. The unit is white with a top control panel and a visible water tank on the side.

2. Important Safety Information

To reduce the risk of fire, electric shock, or injury, always follow these basic precautions:

  • Read all instructions before using the appliance.
  • Do not operate the dehumidifier with a damaged cord or plug.
  • Ensure the appliance is placed on a stable, level surface.
  • Keep the appliance away from heat sources and direct sunlight.
  • Do not block air inlets or outlets. Maintain at least 20 cm clearance around the unit.
  • Unplug the dehumidifier before cleaning or performing any maintenance.
  • Do not use the appliance in areas where flammable liquids or gases are stored.
  • This appliance is for indoor household use only.
  • Children should be supervised to ensure they do not play with the appliance.

3. Package Contents

Please check that all items are present and in good condition:

  • HOMCOM 12L/Day Dehumidifier Unit
  • Continuous Drainage Pipe (60 cm long)
  • User Manual

4. Product Overview

Familiarize yourself with the components and control panel of your dehumidifier.

Top-down view of HOMCOM Dehumidifier showing control panel
Figure 2: Top View with Control Panel

This image provides a top-down view of the dehumidifier, clearly showing the digital control panel and the air outlet grille.

Close-up of digital touch screen control panel with labeled buttons
Figure 3: Digital Touch Screen Control Panel

This close-up image details the digital touch screen control panel. It features buttons for 'LOW HI' (Fan Speed), 'TIMER' (24H Timer), 'UP/DOWN arrows' (Humidity Setting), 'LOCK' (Child Lock), 'POWER WATER FULL' (Indicator/Power), and a central digital display for real-time humidity.

Control Panel Functions:

  • Fan Speed (LOW/HI): Adjusts the fan speed between two modes.
  • Timer (24H): Sets the operating time for the unit.
  • Humidity Setting (Up/Down Arrows): Allows adjustment of the desired humidity level (40%-80%).
  • Lock (Child Lock): Engages/disengages the child lock function.
  • Power/Water Full Indicator: Turns the unit on/off and indicates when the water tank is full (red light).
  • Digital Display: Shows the current humidity level in real-time.

5. Setup

  1. Unpacking: Carefully remove the dehumidifier and all accessories from the packaging.
  2. Placement: Place the dehumidifier on a firm, level surface in the desired room. Ensure there is at least 20 cm of clear space around all sides of the unit for proper airflow. The unit is equipped with 4 rolling casters for easy movement.
  3. Power Connection: Ensure the power switch is off, then plug the power cable into a suitable 230V/50Hz electrical outlet.
  4. Initial Operation: For optimal performance, allow the unit to stand upright for at least 2 hours before first use if it has been transported horizontally.

6. Operating Instructions

6.1 Power On/Off

  • Press the 'Power' button on the control panel to turn the unit ON or OFF.
  • The digital display will show the current room humidity when powered on.
Dehumidifier in a room showing real-time humidity display
Figure 4: Real-time Humidity Display

This image shows the dehumidifier operating in a living space, with a close-up inset of the control panel displaying the current humidity level (e.g., "68").

6.2 Setting Desired Humidity

  • With the unit powered on, use the 'Up' and 'Down' arrow buttons to set your desired humidity level.
  • The adjustable range is between 40% and 80% relative humidity (RH).
  • The unit will operate until the room humidity reaches the set level, then it will cycle off. It will restart automatically if the humidity rises above the set level.

6.3 Fan Speed Adjustment

  • Press the 'Fan Speed' button (LOW/HI icon) to toggle between low and high fan speeds.
  • High speed provides faster dehumidification, while low speed offers quieter operation.

6.4 Timer Function

  • Press the 'Timer' button to set a desired operating duration (up to 24 hours).
  • Each press will increase the timer setting. The unit will automatically turn off once the set time has elapsed.

6.5 Child Lock

  • Press and hold the 'Lock' button for a few seconds to activate the child lock. This prevents accidental changes to settings.
  • Repeat the action to deactivate the child lock.

7. Water Drainage

Your dehumidifier offers two methods for water drainage:

Diagram illustrating dual drainage methods: Manual Drainage and Auto Drainage
Figure 5: Dual Drainage Methods

This diagram visually explains the two water drainage options. On the left, the dehumidifier shows its 2.5L water tank for manual emptying. On the right, it illustrates connecting a hose for continuous auto drainage to a floor drain.

7.1 Manual Drainage (Water Tank)

  • The dehumidifier has a 2.5L water tank.
  • When the water tank is full, the unit will automatically shut off, and the 'POWER WATER FULL' indicator light will turn red.
  • Carefully pull out the water tank from the side of the unit.
  • Empty the collected water.
  • Slide the water tank back into its position until it clicks securely. The unit will resume operation.

7.2 Continuous Drainage (Hose)

  • For continuous operation without needing to empty the tank, attach the included 60 cm drainage pipe.
  • Locate the drainage outlet on the back or side of the unit (refer to product diagrams if available).
  • Connect one end of the drainage pipe to the outlet.
  • Route the other end of the pipe to a suitable floor drain or a larger container, ensuring the pipe is sloped downwards to allow gravity drainage.

8. Maintenance

Regular maintenance ensures optimal performance and longevity of your dehumidifier.

8.1 Cleaning the Air Filter

  • It is recommended to clean the air filter every two weeks or more frequently if used in a dusty environment.
  • Unplug the dehumidifier from the power outlet.
  • Remove the air filter (usually located at the back or side intake grille).
  • Wash the filter with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinstalling.
  • Do not operate the dehumidifier without the filter or with a wet filter.

8.2 Cleaning the Unit Exterior

  • Wipe the exterior of the unit with a soft, damp cloth.
  • Do not use harsh chemicals, abrasives, or solvents, as these may damage the surface.

8.3 Storage

  • If storing the unit for an extended period, ensure the water tank is empty and clean.
  • Clean the air filter.
  • Store the dehumidifier in an upright position in a cool, dry place, away from direct sunlight.

9. Troubleshooting

Before contacting support, please refer to the following common issues and solutions:

ProblemPossible CauseSolution
Dehumidifier does not turn on.No power; Power button not pressed; Water tank full.Check power connection; Press power button; Empty water tank and ensure it's correctly seated.
Unit is running but not collecting water.Room temperature too low; Humidity setting too high; Air filter clogged.Dehumidifiers are less effective below 5°C; Lower desired humidity setting; Clean the air filter.
Unit is noisy.Unit not on a level surface; Air filter clogged; Obstruction in fan.Place on a flat surface; Clean air filter; Check for and remove any obstructions.
Water tank full indicator is on, but tank is not full.Water tank not correctly seated; Float switch malfunction.Ensure water tank is pushed in completely; Contact customer support if issue persists.

10. Specifications

FeatureSpecification
Model Number821-010V70WT
BrandHOMCOM
ColourWhite
MaterialABS, Copper, Aluminium
Overall Dimensions (L x W x H)28.8 cm x 19.8 cm x 50.9 cm
Suitable for Area18-28 m²
Dehumidification Capacity Per Day12 Litres (at 30 °C, RH80%)
Water Tank Volume2.5 Litres
Working Temperature (Best)5-50 °C
Adjustable Humidity Range40%-80% RH
Air Circulation (Wind)90 m³/h
Working Noise≤35 dB
Power210 W
Input230V/50Hz, 1A/230W
Power Cable Length1.5 m
RefrigerantR290
CertificationCE
OriginMainland China
Plug TypeUK Plug

11. User Tips

  • Optimal Placement: For best results, place the dehumidifier in the center of the room or the area with the highest humidity. Avoid placing it directly against walls or furniture.
  • Closed Environment: To maximize efficiency, keep windows and doors closed in the room where the dehumidifier is operating.
  • Regular Cleaning: A clean air filter significantly improves the unit's performance and energy efficiency. Make sure to clean it regularly.

12. Warranty and Support

For warranty information, please refer to the warranty card included with your purchase or contact the retailer/manufacturer directly. Keep your proof of purchase for any warranty claims.

If you encounter any issues not covered in the troubleshooting section, or require further assistance, please contact HOMCOM customer support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.