ASAIR AFD4100

Contents

ASAIR AFD4100 Vortex Flowmeter User Manual

Model: AFD4100

1. Introduction

Thank you for purchasing the ASAIR AFD4100 Vortex Flowmeter. This manual provides essential information for the safe and efficient use of your device. The AFD4/AFD5 series, including the AFD4100, is a vortex flow meter based on the Von Karman vortices principle, designed for accurate liquid flow measurement. It offers long service life, contamination resistance, high accuracy, fast response, and no drift, making it suitable for demanding OEM applications.

The AFD4 series has obtained EU export certifications: REACH, ROHS, and CE.

1.1 Basic Product Information

  • Product Series: AFD4/AFD5 Vortex Flowmeter
  • Applicable Models: AFD4020, AFD4040, AFD4100
  • Manufacturer: Shenzhen Bagul Technology Co., Ltd.

A detailed user manual (PDF) is available for download here.

2. Safety Warnings

Before using this product, please read and comply with all safety instructions.

2.1 Electrical Safety

  • Use only the power adapter provided with the product or a compliant power supply.
  • If the power cord is damaged, do not continue to use it. Contact support for a replacement.
  • Always disconnect the power before cleaning.

2.2 Usage Environment

  • Operating Temperature Range: -10°C to 65°C (refer to specifications for exact model details).
  • Avoid direct sunlight, high temperatures, and dusty environments.
  • Keep the ventilation good and do not block heat dissipation holes.
  • Do not use in humid environments unless the product specifically states a waterproof rating (AFD4100 has IP65 rating).

2.3 Operational Safety

  • Do not disassemble or modify the product yourself, as there are no user-repairable parts inside.
  • Prevent liquid from entering the product interior.
  • If the product emits smoke, unusual odors, or abnormal noise, immediately disconnect the power.

3. Setup and Installation

3.1 Unpacking Inspection

  • After opening the package, check that all items are complete:
    • 1 x Vortex Flow Meter
    • 1 x M8 Cable
    • 1 x Product Quality Certificate
  • If you find any items missing or damaged, please contact customer service immediately.

3.2 First Use

  • Check if the power supply voltage is consistent with the product specifications (18-28VDC).

3.3 Installation Guidelines

The inlet of the flowmeter needs to be connected to a long straight pipe. Refer to the detailed specifications for specific pipe length requirements. The installation environment should avoid vibration and strong electromagnetic interference.

Product Parameters of AFD4 Series with dimensions
Figure 1: Product Parameters of AFD4 Series, showing physical dimensions and size chart for AFD4020, AFD4040, and AFD4100 models.
AFD4 Series Model Number Breakdown
Figure 2: Diagram illustrating the model number breakdown for the AFD4 series, including options for thread type, flow range, output signal, and screen/temperature measurement module configurations.

Note: The product with NPT threads needs to be customized, with a minimum order quantity of 50pcs and a customization cycle of at least one month.

Optional Flange Versions
Figure 3: Optional Flange Versions, showing both old and new model flanges. The product may be delivered with either type at random.

4. General Operating Instructions

4.1 Basic Operations

  • Power On/Off: Press and hold the power button for 3 seconds to turn the device on or off.
  • Function Selection: Short press the mode button to switch functions.
  • Display Screen: If equipped with a screen, it will show the current flow value, temperature, and status.
AFD4040 Flow Sensor with Screen Display
Figure 4: AFD4040 Flow Sensor with a digital screen, showing flow rate and temperature readings.

5. Technical Specifications

The following table provides detailed technical specifications for the AFD4 series, including the AFD4100 model.

Parameter Comparison Table for AFD4, AFD4 (IO-Link), and AFD5 Series
Figure 5: Parameter Comparison Table for AFD4 Series, AFD4 (IO-Link), and AFD5 Series, detailing various technical specifications.
ParameterSpecification (AFD4 Series)
Model NumberAFD4100
Flow Range10-100 L/min (for AFD4100)
Optional FeaturesScreen and Temperature Measurement Module
Accuracy<3.0% F.S (flow); ±5% F.S. max. (Temperature)
Repeatability<2%
Working Pressure10 bar (max. pressure 16 bar)
Fluid Temperature0-90°C (no freezing or condensation)
Working Environment-10°C to 65°C
Storage Environment-20°C to 80°C
MaterialPPS/SUS304
Interface SpecificationsThread type: G/RC/NPT (e.g., G3/4, RC3/4, G1, RC1, NPT3/4, NPT1 for AFD4100). Joint Pipe Bore Size: 1-1/4" (general).
Supply Voltage18-28VDC
Signal Output3-wire 4-20mA or RS485 or NPN or PNP or 1-5V
Protection LevelIP65

6. Troubleshooting Common Problems

ProblemPossible ReasonsSolution
Unable to power onPower not connected/battery depletedCheck the power connection, charge (if applicable) and try again.
No display/Display errorPoor connection/Incorrect settingsRestart the device and check the connection.
Inaccurate measurement values (instrument-related)Range error/calibration requiredConfirm the measurement range and contact calibration services.
Flow rate not accurate (too large/small or no flow)1. Connecting pipe does not meet specifications.
2. Liquid does not meet requirements.
3. Vibration or interference in installation environment.
1. Verify connecting pipe meets specifications.
2. Ensure liquid properties are compatible.
3. Check installation environment for stability and absence of interference.
Different flow rates for the same pipeline (before and after)Different placement and pressure resistance.Ensure consistent installation and pressure conditions for accurate comparative readings.
Other faults—Contact customer service for technical support.

6.1 User Tips

  • For optimal accuracy, ensure the liquid being measured is non-corrosive, non-condensable, free of particles, and has a density similar to water. If unsure, consult customer service.
  • Always refer to the installation specifications for proper front and rear connecting pipe lengths to minimize flow disturbances.

7. Maintenance and Care

  • Cleaning: Wipe the outer casing with a soft, dry cloth. Do not use chemical solvents.
  • Storage: When not in use for an extended period, clean and store in a cool, dry place.
  • Calibration: It is recommended to calibrate annually to ensure measurement accuracy. For calibration services, contact a professional organization or customer service.

8. EU Compliance Information

8.1 CE Declaration of Conformity

This product complies with the essential requirements of the following EU directives:

  • Low Voltage Directive (LVD) 2014/35/EU
  • Electromagnetic Compatibility Directive (EMC) 2014/30/EU
  • RoHS Directive 2011/65/EU

8.2 Waste Disposal (WEEE)

The wheeled bin symbol marked with an X on the product indicates that, according to EU Directive 2012/19/EU, this product must not be disposed of as unsorted municipal waste and must be collected and recycled separately.

9. Warranty and Support

Warranty Policy: 12/24 months from the date of purchase (subject to store announcement).

Technical Support: For detailed technical documentation, calibration certificates, or hard copies of the manual, please contact customer service via the platform's internal messaging system.

10. Disclaimer

This instruction manual is a general version; the actual product functions and parameters shall prevail. The manufacturer reserves the right to change product designs and specifications without prior notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.