1. Introduction

The Jiubei MAM-6070 is an advanced control panel designed for industrial air compressors. It provides comprehensive monitoring and control functionalities, ensuring efficient and reliable operation of screw air compressors. This manual provides essential information for the proper installation, operation, and maintenance of your MAM-6070 controller.

2. Product Overview

The MAM-6070 controller features a clear display and intuitive controls for managing your air compressor system. It is designed for durability and ease of use in industrial environments.

Video: Overview of the MAM-6070 PLC and associated screw air compressor parts, highlighting the unit's components and label with specifications.

MAM-6070 Controller Display

Image: Front view of the MAM-6070 controller display, showing real-time operational data such as pressure (0.41 MPa), temperature (094 ℃), and current (00.0 A). The display also indicates the device status as 'Equipment Stopped' and shows total running time (00073:30:00) and load time (00073:29:36). Control buttons for 'Menu', 'Change', 'Switch', 'Start', 'Stop', and 'Alarm' are visible on the right side.

3. Specifications

AttributeValue
Product NameController
ModelMAM-6070
TypeHand Tool Parts, Controller
ApplicationAir compressor controller
UsageAir compressor parts
Used forScrew air compressor
Power Input16-28V~ 50/60Hz 10W (220/380V)
OriginMainland China (Guangdong)
ConditionNew
PackageCarton Box
Warranty1 Year

4. Package Contents

Upon opening the package, verify that all components are present and undamaged:

  • MAM-6070 Controller Unit
  • Terminal Blocks for wiring connections
  • (Optional) Mounting hardware
MAM-6070 Controller and Terminal Blocks

Image: The MAM-6070 controller unit alongside its detachable terminal blocks, which are used for electrical connections.

MAM-6070 Controller in Packaging with Label

Image: The MAM-6070 controller unit, still partially in its protective packaging, showing the product label with model number MAM6070(B)(T)(V)(200), part number CK1333M005-1, power specifications (16-28V~ 50/60Hz 10W, 220/380V), and serial number S/N: 2212261746.

5. Setup and Installation

Proper installation is crucial for the safe and reliable operation of the MAM-6070 controller. It is recommended that installation be performed by qualified personnel.

5.1. Mounting

The controller is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Secure the unit using appropriate fasteners.

5.2. Electrical Connections

Connect the MAM-6070 controller to your air compressor system according to the wiring diagram provided with your specific compressor model and the terminal layout on the controller. Refer to the label on the unit for power input requirements (16-28V~ 50/60Hz 10W, compatible with 220/380V systems).

MAM-6070 Terminal Block Connections

Image: Close-up view of the MAM-6070 controller's terminal block, showing numbered connection points (e.g., 10, 12, 14, 16) for electrical wiring. Ensure correct wiring based on your system's requirements.

Important: Always ensure the power supply is disconnected before making any electrical connections to prevent electric shock or damage to the equipment.

6. Operation

The MAM-6070 controller provides real-time monitoring and control of your air compressor. The display shows critical operational parameters, and buttons allow for system management.

6.1. Display Interface

The main display provides the following information:

  • Pressure: Current system pressure (e.g., 0.41 MPa).
  • Temperature: Current system temperature (e.g., 094 ℃).
  • Current: Electrical current draw (e.g., 00.0 A).
  • Operating Status: Indicates the current state of the equipment (e.g., 'Equipment Stopped').
  • Total Running Time: Cumulative operational time (e.g., 00073:30:00).
  • Load Time: Cumulative time under load (e.g., 00073:29:36).

6.2. Control Buttons

The buttons on the right side of the display allow for interaction with the controller:

  • Menu: Accesses the main menu for configuration and settings.
  • Change: Navigates through menu options or changes displayed values.
  • Switch: Toggles between different display screens or parameters.
  • Start: Initiates the air compressor operation.
  • Stop: Halts the air compressor operation.
  • Alarm: Indicates an active alarm or allows access to alarm history.

6.3. Starting and Stopping the Compressor

  • To Start: Press the 'Start' button. The controller will initiate the compressor's startup sequence.
  • To Stop: Press the 'Stop' button. The controller will safely shut down the compressor.

7. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your MAM-6070 controller and the connected air compressor system.

  • Cleaning: Keep the display and control panel clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid abrasive cleaners or solvents.
  • Inspections: Periodically check all wiring connections to ensure they are secure. Look for any signs of wear, corrosion, or damage.
  • Environmental Conditions: Ensure the controller operates within its specified environmental conditions (temperature, humidity) to prevent malfunction.
  • Firmware Updates: Consult the manufacturer for information on available firmware updates, if any, and follow their instructions for installation.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your MAM-6070 controller. For complex problems, contact technical support.

ProblemPossible CauseSolution
Controller does not power onNo power supply; Incorrect wiring; Blown fuseCheck power connections; Verify wiring against diagram; Inspect and replace fuses if necessary.
Compressor does not startEmergency stop engaged; System fault; Incorrect settingsDisengage emergency stop; Check for alarm messages on display; Review operating settings.
Display shows error/alarmSystem malfunction; Sensor error; Parameter out of rangeNote the error code/message; Consult the compressor's manual for specific alarm meanings; Contact technical support if unresolved.
Inaccurate readingsFaulty sensor; Calibration neededCheck sensor connections; Consider recalibration or sensor replacement by a technician.

9. User Tips

  • Always refer to the specific wiring diagram provided with your air compressor for accurate connection instructions.
  • Regularly back up any custom settings or configurations if the controller supports this feature.
  • Keep the controller's display and buttons clean to ensure clear visibility and proper function.

10. Warranty and Support

The Jiubei MAM-6070 Air Compressor Controller comes with a 1-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your supplier or the manufacturer's authorized service center. Provide your product model (MAM-6070) and serial number (S/N: 2212261746, if applicable) when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.