1. Product Overview
The ANENG SZ308 is a high-precision digital multimeter designed for electricians and electronic maintenance. It offers multiple functions including AC/DC voltage, DC current, resistance, hFE triode test, diode test, buzzer (continuity), and square wave output.

ANENG SZ308 Digital Multimeter with test leads.
1.1 Accessories List
- Pen line (Test Leads)
- Multimeter (Main Unit)
- User Manual
- Packing Box

Included accessories for the ANENG SZ308.
1.2 Product Dimensions

Dimensions: 12.18cm (4.79inch) x 6.65cm (2.61inch) x 3.35cm (1.32inch).
2. Setup
2.1 Battery Installation
The ANENG SZ308 requires one 6F22 9V battery (not included). Follow these steps for installation:
- Press and hold the battery compartment cover hard, then push the battery cover up at the same time to open it.
- Load a 6F22 9V battery, paying attention to the corresponding positive (+) and negative (-) electrodes.
- After installing the battery, align the battery cover from top to bottom and push it back until it clicks into place.

Visual guide for battery installation.
2.2 Probe Connection
Insert the test leads (pen bus) into the corresponding ports on the multimeter. The red lead connects to the positive (+) or VΩmA port, and the black lead connects to the COM (common) port.

Diagram of the multimeter panel and probe connection points.
3. Operating Instructions
The ANENG SZ308 features a function turntable to select different measurement modes. Ensure the correct mode is selected and probes are connected properly before taking measurements.
Product demonstration and usage guide video.
3.1 Measurement Modes
Below are instructions for common measurement functions:
DC Current Measurement (DCA)
To measure DC current, switch the function turntable to the appropriate DCA gear (e.g., 2mA, 10A). The multimeter must be connected in series with the circuit. For current measurements, the red dial pen is plugged into the DCA current jack of the multimeter.

Important: Current must be measured in series to the circuit.
DC Voltage Measurement (DCV)
Switch the function turntable to the DCV gear (e.g., 200mV - 1000V). Connect the red probe to the positive (+) terminal and the black probe to the negative (-) terminal of the component or power source you are measuring.
AC Voltage Measurement (ACV)
Switch the function turntable to the ACV gear (0V-750V). Connect the probes to the AC voltage source. Note: There may be a slight delay in measurement, which does not affect the accuracy of the numerical values.

Measuring household AC voltage.
Resistance Measurement (Ω)
Switch the function turntable to the Resistance gear (0Ω-2000kΩ). Contact both sides of the resistance with the test leads.
Diode Test
Switch the function turntable to the Diode gear. The test leads contact the positive and negative electrodes of the diode. The display will show the forward voltage drop.
Buzzer (Continuity) Test
Switch the function turntable to the Buzzer gear. The test buzzes on and off, and the buzzer sounds to indicate normal patency (continuity).
Square Wave Output
Switch the function turntable to the Square Wave gear. Connect the square wave device as shown in the figure, connect the device with a multimeter, and test the signal.
hFE Triode Test
Switch the function turntable to the hFE transistor gear. Insert the transistor into the corresponding slots, ensuring it is of PNP or NPN type.

Visual examples of various measurement tests.
4. Specifications
| Function | Range | Resolution | Precision |
|---|---|---|---|
| AC Voltage | 0V-750V | 0.1V-1V | ±(1.0%+15) |
| DC Voltage | 200mV-1000V | 0.1mV-1V | ±(1.0%+10) |
| DC Current | 2mA-10A | 0.01mA-0.01A | ±(1.5%+5) |
| Resistance | 0Ω-2000kΩ | 0.1Ω-1kΩ | ±(1.2%+5) |
| hFE Triode | YES | Material | ABS |
| Diode | YES | Battery | 6F22 9V Battery |
| Buzzer | YES | Weight | 72g |
| Square Wave | YES | Max Digital Display | 1999 Counts |
| Low Battery Indication | YES | Pen Bus Length | 70cm/27.5inch |
Note: The above parameters are for reference only, and the actual measurement of the specific equipment shall prevail.
5. Maintenance
To ensure the longevity and accuracy of your ANENG SZ308 Digital Multimeter, follow these maintenance guidelines:
- Cleaning: Use a soft, damp cloth to clean the exterior of the multimeter. Do not use abrasive cleaners or solvents.
- Storage: Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery to prevent leakage.
- Battery Replacement: Replace the 9V battery promptly when the low battery indication appears on the LCD screen to ensure accurate readings and proper operation.
- Calibration: For professional use or if you suspect inaccuracies, periodic calibration by a qualified technician is recommended.
6. Troubleshooting
Here are some common issues and their potential solutions:
- Display shows "1" or "OL": This typically indicates an over-range condition. The measured value exceeds the selected range. Try switching to a higher range setting.
- No display or faint display: Check the battery. It might be dead or low. Replace the 9V battery if necessary.
- Inaccurate readings: Ensure the test leads are properly inserted into the correct ports for the selected measurement function. Check the battery level. If the issue persists, the multimeter may require calibration.
- No continuity sound during buzzer test: Ensure the circuit is complete and the components are not open. Check the test leads for damage.
7. User Tips
- Always start with the highest range setting when measuring an unknown value to prevent damage to the multimeter.
- Double-check your connections before applying power or taking a measurement, especially when measuring current.
- Keep the multimeter and test leads clean and free from dust and debris.
- Avoid dropping the multimeter or subjecting it to strong impacts, as this can affect its internal components and accuracy.
8. Warranty and Support
For any questions, technical support, or warranty claims, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific contact information and warranty terms.