TOMZN TOQ7

Contents

TOMZN TOQ7 Series DIN Rail Automatic Transfer Switch User Manual

Model: TOQ7

1. Safety Information

Warning: To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or play pens. This bag is not a toy.

1.1 General Safety Precautions

  • After receiving the product, ensure an electrical professional performs the initial operation and installation.
  • Connect the equipment strictly in accordance with the provided wiring diagram specifications.
  • Adjust equipment parameters according to these instructions.

1.2 Operational Precautions

  • Do not place the device near flammable materials.
  • Ensure adequate ventilation during operation to prevent overheating.
  • Disconnect from power and store properly when not in use for extended periods.

2. Product Overview

The TOMZN TOQ7 series Automatic Transfer Switch (ATS) is a miniature household power transfer switch designed to automatically switch between a main power supply and a backup power supply. This ensures continuous, reliable, and safe power delivery, especially during outages of the main supply. It is suitable for DIN rail installation in PZ30 distribution boxes.

The ATS features a solid structure, reliable conversion, convenient installation, and long service life. It can be operated electrically (automatically) or manually. The device is composed of a Transfer Switching Equipment (TSE) and a controller, formulated according to IEC/EN60947-6-1 and GB/T14048.11 standards.

2.1 Key Features

  • Millisecond Switching: Automatic switching after power off in less than 50ms for uninterrupted power.
  • Dual Power Source: Manages power transfer between city power and a generator or photovoltaic system.
  • Safety Design: Features a safe arc extinguishing chamber, isolation plates for secure input/output, and a safety shield to prevent accidental contact.
  • Durable Components: Utilizes industrial silver contacts for improved service life and conductive performance.
  • Easy Installation: Designed for 35mm standard DIN rail installation.
  • High Power Load Support: Capable of supporting up to 125A, suitable for various household and industrial equipment.

2.2 Product Demonstration

Video: Overview of the TOMZN TOQ7 Automatic Transfer Switch functionality.

3. Specifications

3.1 Technical Parameters

ParameterValue
Brand NameTOMZN
Model NumberTOQ7
TypeMini Circuit breaker, Dual Power Automatic Transfer Switch
Rated Current (le)63A, 100A, 125A (available in 16A, 20A, 25A, 32A, 40A, 50A, 80A as well)
Rated Insulation Voltage (Ui)AC 690V, 50/60Hz
Rated Voltage (Ue)AC 400V, 50/60Hz (L+N 110V-120V 50-60Hz for control)
ClassificationPC class: Can be manufactured and withstood without short circuit current
Utilization CategoryAC-33iB, AC-31B
Pole No.2P, 3P, 4P
Weight (approx.)1.7kg (2P), 2.1kg (3P), 2.6kg (4P)
Electrical Life2000 times
Manual Operation Life5000 times
Rated Short Circuit Current (Iq)50kA
Short Circuit Protection Device (Fuse)RT16-00-63A
Rated Impulse Withstand Voltage8kV
Control Circuit VoltageAC 220V 50/60Hz (Normal working conditions: 85-110% Us)
Auxiliary Circuit2 relays, each with two sets of contact converter contact capacity: AC220V/50Hz le=5y
Conversion Time of Contactor<50ms
Operation Conversion Time<50ms
Return Conversion Time<50ms
Power Off Time<50ms
Wireless FunctionalityNo
Battery IncludedNo
EU LVD VoltageHigh voltage: Above 50Vac or 75Vdc
High-concerned chemicalnone
Is Smart DeviceNo
OriginMainland China
CertificationCE

3.2 Dimensions

  • Height: 109mm for all models.
  • Width: 108mm (2P), 125mm (3P), 142mm (4P).
  • Depth: 78mm for all models.
Dimensions for 2P TOQ7 ATS

Figure: Dimensions for 2P TOQ7 ATS (109mm H x 108mm W)

Dimensions for 3P TOQ7 ATS

Figure: Dimensions for 3P TOQ7 ATS (109mm H x 125mm W x 78mm D)

Dimensions for 4P TOQ7 ATS

Figure: Dimensions for 4P TOQ7 ATS (109mm H x 142mm W x 78mm D)

4. Setup and Installation

Installation and wiring of the TOMZN TOQ7 ATS should only be performed by qualified electrical professionals. Always ensure all power supplies are disconnected before beginning any installation work.

4.1 Pre-Installation Check

  • Inspect the ATS for any physical damage or missing components.
  • Operate the ATS manually using the operating handle to check the flexibility of the transmission device and verify load generation and disconnection conditions for both common and standby power supplies.

4.2 Installation Conditions

  • The ATS can be installed vertically in a control cabinet or distribution cabinet.
  • Ensure the installation distance meets the requirements specified in the manual (refer to Figure 8 in the original PDF for details on S1 and S2 safe distances).
  • The maximum ambient temperature should not exceed 40°C, and the minimum should not be lower than -5°C. The average temperature within 24 hours should not exceed 35°C.
  • The installation altitude should not be higher than 2000m.
  • Relative humidity should not exceed 50% at 40°C. At -5°C, higher humidity is acceptable (e.g., 90% at 25°C).
  • Special measures may be needed to address occasional condensation on the product surface due to temperature changes.
  • The pollution grade of the ATS conforms to grade 3, and the installation type conforms to the category specified in IEC/EN60947-6-1 and GB/T14048.11.
35mm standard DIN rail installation

Figure: The ATS is designed for 35mm standard DIN rail installation.

4.3 Wiring Instructions

Connect the ATS according to the specific wiring diagram for your pole configuration (2P, 3P, or 4P). The cross-sectional area of the copper wire for the control circuit should not be greater than 2.0mm². Ensure appropriate circuit breakers are provided in the power distribution system for safety.

Easy wiring diagram for 2P ATS

Figure: Easy wiring diagram for 2P ATS, showing common power input, common control lines, backup power input, backup control line, and load output.

Wiring diagram for 3P ATS

Figure: Wiring diagram for 3P ATS, showing common incoming line, common zero line input, standby incoming line, standby zero line input, and load output.

Wiring diagram for 4P ATS

Figure: Wiring diagram for 4P ATS, showing common incoming line, common control line, standby incoming line, standby control line, and load output.

Wiring diagram for photovoltaic inverter connection

Figure: Special connection mode wiring diagram for photovoltaic inverter.

For detailed wiring diagrams and installation dimensions, please refer to the official user manual PDF available at this link.

5. Operation

The TOMZN TOQ7 ATS supports both automatic and manual operation modes.

5.1 Automatic Mode

When the main power supply is cut off or becomes abnormal, the ATS will automatically switch to the backup power supply within 50 milliseconds. Once the main power supply is restored, the device will automatically switch back to the main power supply. This ensures an uninterrupted power supply to your connected loads.

Automatic switching after power off in less than 50ms

Figure: Automatic switching occurs in less than 50 milliseconds.

5.2 Manual Mode

The ATS can be manually operated using the selector switch. To operate manually, pull the selector switch to the 'Manual' position. After completing manual operations, always return the selector switch to the 'Auto' position for normal automatic functionality.

Important Note for Manual Operation:

  • While the ATS guarantees performance during automatic operation, manual operation may not provide the same level of performance due to variations in power generation/failure speed or operator action.
  • Excessive silver alloy loss may occur during manual power generation and power failure.
  • Only use manual mode when all power supplies are cut off for checking and maintaining the operating system and contacts.
Manual and Automatic mode switch

Figure: Manual handle and Manual/Automatic switch for selecting operation mode.

5.3 Control Circuit

The ATS control circuit becomes active instantly. After conversion, the coil in the control circuit is disconnected by the internal converter. The coil operates normally under a rated voltage of 80%-110%. Low voltage can cause coil heating and potentially spontaneous combustion.

6. Maintenance, Inspection, and Storage

All maintenance and inspection procedures must be performed by qualified professionals with all power supplies cut off in advance.

6.1 Maintenance Schedule

  • The first maintenance and inspection should be carried out within 6 months after initial use.
  • Subsequent maintenance and inspection should occur at least once a year.
  • In harsh installation conditions (e.g., dusty, humid environments), increase the frequency of maintenance and inspection.

6.2 Maintenance and Inspection Items

  • Cleaning: Remove any dust and dirt from the device.
  • Contact Check: Inspect the electrical contacts for deformation, damage, or burnt metal particles. Remove any burnt particles from and around the contact surfaces.
  • Contact Resistance: If rust, acidification, or dust is present on the contact surface, manually operate the switch multiple times and measure the contact resistance. Replace if necessary.
  • Insulation Resistance: If the device has been exposed to long-term moisture or suspension, dry the ATS before use. After cleaning, use a 500V megohmmeter to measure the insulation resistance between the normal supply, alternating power supply, load side bar, live parts, and metal plate. The insulation resistance should not be less than 10MΩ.

6.3 Storage

Store the ATS in an environment equivalent to normal working conditions, ensuring it is dust-proof, moisture-proof, and protected from collisions.

7. Troubleshooting

This section addresses common issues that may arise with the ATS. Always ensure power is disconnected before attempting any troubleshooting steps.

7.1 Common Issues and Solutions

  • Failure to Switch Automatically:
    • Check if the selector switch is in the 'Auto' position.
    • Verify the presence and stability of both main and backup power supplies.
    • Inspect control circuit wiring for loose connections or damage.
  • Coil Heating or Malfunction:
    • Ensure the control circuit voltage is within the rated 80%-110% range (AC 220V 50/60Hz). Low voltage can cause overheating.
    • Check the cross-sectional area of the control circuit copper wire; it should not exceed 2.0mm².
  • Poor Electrical Contact:
    • Perform maintenance steps as described in Section 6.2, including cleaning contacts and checking for deformation or burnt particles.
    • Measure contact resistance if signs of rust, acidification, or excessive dust are present.
  • Device Not Powering On:
    • Verify all incoming power connections are secure and live.
    • Check associated circuit breakers for trips.

8. User Tips

  • Professional Installation: Always have a certified electrician install and perform initial setup of the ATS to ensure safety and correct operation.
  • Regular Checks: Periodically check the physical condition of the ATS, especially in environments with dust or humidity.
  • Ventilation: Ensure the installation location provides adequate airflow around the unit to prevent heat buildup.
  • Wiring Integrity: Double-check all wiring connections for tightness and proper insulation during maintenance.
  • Understand Modes: Familiarize yourself with both automatic and manual operation modes, and understand when each is appropriate.

9. Warranty and Support

For technical support, service, or warranty inquiries, please contact TOMZN ELECTRIC CO.,LTD. using the information below:

  • Manufacturer: TOMZN ELECTRIC CO.,LTD.
  • Address: No.11, Xinhe Road, Huabei, Liushi Town, Yueqing City, Zhejiang Province, China
  • Service Hotline: 4006-020-158
  • Website: www.tomzn.com

Please retain your purchase receipt for warranty purposes.

© 2023 TOMZN ELECTRIC CO.,LTD. All rights reserved.