Gaqqee JX-4615N-A3

Contents

Gaqqee JX-4615N-A3 Battery Level Indicator User Manual

Model: JX-4615N-A3 | Brand: Gaqqee

1. Product Overview

The Gaqqee JX-4615N-A3 is a versatile battery level indicator board designed to provide real-time voltage and remaining battery level display. It features a high-brightness LED screen, customizable voltage settings, adjustable backlight, and power-off memory. This device is compatible with various battery types, including ternary lithium, lithium iron phosphate, and acid batteries, making it suitable for electric vehicles, energy storage systems, and other industrial and civilian applications.

Gaqqee JX-4615N-A3 Battery Level Indicator showing different display colors
Figure 1: Gaqqee JX-4615N-A3 Battery Level Indicator in various display colors (blue, green, red, white).
Play video
Watch video online
Video 1: A brief demonstration of the battery level indicator's functionality and display.

2. Setup Instructions

2.1 Wiring

Connect the red wire to the positive (+) terminal (VCC) and the black wire to the negative (-) terminal (GND) of your battery or power source. Ensure the voltage is within the supported range of DC 7-55V.

Back view of the battery level indicator showing VCC and GND wiring points
Figure 2: Rear view of the JX-4615N-A3 module, indicating VCC (positive) and GND (negative) connection points.

2.2 Initial Power-On and Default Settings

Upon first power-on, the product defaults to the ternary lithium battery L03S (L03) series voltage setting.

2.3 Mode Setting (Battery Type Selection)

To enter the setting page, press and hold the 'TEST' button for 2 seconds from the normal display page. Once in the settings, you can select the battery type and number of strings:

  1. Ternary Lithium Battery (L-mode):

    From the setting page, press and hold the button for 2 seconds to switch to the ternary lithium battery L03 setting page. Continue to press and hold the button for 2 seconds to select the number of battery strings (03-12S). After selecting, press and hold the button for 2 seconds to confirm and save the setting. The display will become steady. To return to the home page, press and hold the button for 2 seconds, or short press to enter the next setting page.

    Ternary lithium battery setting mode showing L03
    Figure 3: Setting page for Ternary Lithium Battery, displaying 'L03'.
  2. Lithium Iron Battery (F-mode):

    From the main page, press and hold the button for 2 seconds to enter the setting page. Press and hold the button for 2 seconds to switch to the lithium iron battery F03 setting page. Press and hold the button for 2 seconds to select the number of battery strings (03-14S). Confirm and save by pressing and holding the button for 2 seconds until the display is steady. Long press for 2 seconds to return to the main page, or short press to enter the next setting page.

    Lithium iron battery setting mode showing F03
    Figure 4: Setting page for Lithium Iron Battery, displaying 'F03'.
  3. Acid Battery (P-mode):

    From the main page, press and hold the button for 2 seconds to enter the setting page. Press and hold the button for 2 seconds to switch to the acid battery P12 setting page. The battery voltage will blink (12 blinks). Press and hold the key to select 12V/24V/36V/48V battery voltage. Confirm and save by pressing and holding the button for 2 seconds until the display is steady. Long press for 2 seconds to return to the main page, or short press to enter the next setting page.

    Acid battery setting mode showing P12
    Figure 5: Setting page for Acid Battery, displaying 'P12'.

2.4 Custom High and Low Voltage Settings

To set custom high and low voltage thresholds:

  1. From the main page, press and hold the 'TEST' button for 2 seconds to enter the setting page.
  2. Press and hold the button for 2 seconds to switch to the custom setting page.
  3. Enter the low voltage setting page. Press and hold the button for 2 seconds to change the value.
  4. Press and hold the button for 2 seconds to shift the value (move to the next digit).
  5. After setting the low voltage value, press and hold the button for 2 seconds to confirm and save. The value will become steady.
  6. Press and hold the button again for 2 seconds to switch to the high voltage setting page.
  7. The first digit on the left side of the button will flash. Press and hold the button for 2 seconds to change the value.
  8. Press and hold the button for 2 seconds to shift the value.
  9. After setting the high voltage value, press and hold the button for 2 seconds to confirm and save. The setting is complete.
  10. Long press the button for 2 seconds to return to the main page, or short press the button to enter the next setting page.
Custom high and low voltage settings display
Figure 6: Display for custom high and low voltage settings.

2.5 Backlight Time Settings

To adjust the backlight duration:

  1. From the home screen, press and hold the 'TEST' button for 2 seconds to enter the setting page.
  2. Press and hold the button for 2 seconds to switch to the backlight B-0 setting page.
  3. Press and hold the button for 2 seconds to set a parameter from 0 to 6.
  4. Select the desired parameter and press and hold the button for 2 seconds to confirm and save. The value will become steady.
  5. Long press the button for 2 seconds to return to the home screen, or short press to enter the next setting page.

Backlight Options:

  • B-0: Backlight is steady on; manual key press required to turn off.
  • B-1: Turn off display after 10 seconds (factory default).
  • B-2: Turn off display and enter low power consumption after 20 seconds.
  • B-3: Turn off display and enter low power consumption after 30 seconds.
  • B-4: Turn off display and enter low power consumption after 40 seconds.
  • B-5: Turn off display and enter low power consumption after 50 seconds.
  • B-6: Turn off display and enter low power consumption after 60 seconds.
Backlight time settings display showing b-0
Figure 7: Display for backlight time settings, showing 'b-0'.

3. Operating Instructions

3.1 Normal Display

In the normal display mode, the screen shows the current voltage and battery level. A short press on the 'TEST' button will turn the display off and on.

Key description for normal display page
Figure 8: Key description for normal display page, illustrating short press for on/off and long press for settings.

3.2 Low Voltage Alarm

When the battery power drops to 10% or lower, the red battery grid on the display will flash, indicating a low battery condition.

3.3 Power Failure Memory

The device includes a power-off memory function, ensuring that all current power information and other important settings are automatically saved and retained even after an unexpected power outage.

4. Specifications

Feature Specification
Model Number JX-4615N-A3
Brand Name Gaqqee
Voltage Measurement Range DC 7-55V (Red display: DC 7-40V)
Working Current ≤ 20mA
Display Type Digital Only (LED screen)
Display Colors Red, Green, Blue, White (optional)
Ternary Lithium Battery Measurement 3S~12S
Lithium Iron Battery Measurement 3S~14S
Acid Battery Measurement 12V/24V/36V/48V
Product Size 46mm x 15mm x 3mm (1.81in x 0.59in x 0.12in)
Power Supply DC
Certification CE
Origin Mainland China
Product parameter diagram with dimensions
Figure 9: Product dimensions and key parameters.

5. Maintenance

The Gaqqee JX-4615N-A3 Battery Level Indicator is designed for low maintenance. Keep the device clean and dry. Avoid exposure to extreme temperatures, moisture, or corrosive environments. Do not attempt to disassemble the unit, as this may void any potential warranty and could damage the device.

6. Troubleshooting

If you encounter issues with your battery level indicator, consider the following:

  • No Display: Check the wiring connections (VCC and GND) to ensure they are secure and correctly polarized. Verify that the input voltage is within the DC 7-55V range.
  • Incorrect Reading: Ensure the correct battery type (Ternary Lithium, Lithium Iron, or Acid) and number of strings have been selected in the settings. Recalibrate custom voltage settings if applicable.
  • Display Flashing: If the red battery grid is flashing, this indicates a low battery alarm (battery level at or below 10%).
  • Display Not Turning Off/On: A short press of the 'TEST' button toggles the display. Check backlight settings (B-0 to B-6) if the display remains on or off unexpectedly.

For persistent issues not resolved by these steps, please contact customer support.

7. User Tips

Based on general usage, here are some tips for optimizing your experience:

  • Always double-check your battery type and string count before setting up the indicator to ensure accurate readings.
  • Utilize the backlight time setting to conserve power, especially in applications where continuous display is not required.
  • The power-off memory function is robust, but it's good practice to confirm settings after any major changes.

Note: Specific user tips from reviews or Q&A are not available at this time.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the point of purchase. Keep your proof of purchase for any warranty claims.

A detailed user manual in PDF format may be available from the seller. Please check the product page or contact the seller for access to the PDF manual if needed.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.