1. Introduction

This manual provides essential information for the safe and effective operation of your Hantek DSO5072P Digital Storage Oscilloscope. Please read this manual thoroughly before using the device and keep it for future reference.

Key Features:

  • 70MHz Bandwidth
  • 2 Channels
  • 1GSa/s Real-Time Sample Rate
  • Large 7.0-inch WVGA (800x480) Color Display
  • Record Length up to 40K
  • Multiple Trigger Modes: Edge, Pulse Width, Line Selectable Video, Slope, Overtime, etc.
  • USB Host and Device Connectivity
  • Multiple Automatic Measurements
  • Four Math Functions, including FFT
  • Software for PC Real-Time Analysis

2. Package Contents

Verify that all items listed below are present and in good condition upon unpacking:

  • 1 x Hantek DSO5072P Oscilloscope
  • 2 x Oscilloscope Probes
  • 1 x USB Cable
  • 1 x Power Cable
  • 1 x CD & Manual (digital copy of this manual)
Hantek DSO5072P Oscilloscope and accessories
Figure 2.1: Hantek DSO5072P Oscilloscope and included accessories.

3. Setup

3.1 Initial Inspection

Before connecting the oscilloscope, inspect the device and all accessories for any signs of damage. Ensure the power cable and probes are intact.

3.2 Power Connection

  1. Connect the provided power cable to the power input on the rear panel of the oscilloscope.
  2. Plug the other end of the power cable into a suitable AC power outlet.
  3. Press the power button to turn on the oscilloscope.
Rear view of Hantek DSO5072P showing power input
Figure 3.1: Rear panel of the DSO5072P, highlighting the power input.

3.3 Probe Connection and Compensation

  1. Connect the oscilloscope probes to the CH1 and CH2 input BNC connectors on the front panel.
  2. Attach the probe ground clip to the ground terminal.
  3. Connect the probe tip to the probe compensation output (usually a square wave signal).
  4. Adjust the probe compensation screw until a flat-top square wave is displayed on the screen. This ensures accurate measurements.
Front view of Hantek DSO5072P with probes connected
Figure 3.2: Front panel of the DSO5072P, showing probe connections.

3.4 USB Connectivity

The oscilloscope features USB host and device ports for data transfer and PC connectivity. Use the provided USB cable to connect the oscilloscope to a computer for real-time analysis using the Hantek software (included on CD).

Hantek DSO5072P USB port
Figure 3.3: USB port on the Hantek DSO5072P for data transfer.

4. Operating Instructions

4.1 Basic Waveform Display

  1. After power-on and probe compensation, connect the probe to the circuit you wish to measure.
  2. Adjust the VOLTS/DIV knob for the desired vertical scale and the TIME/DIV knob for the horizontal scale.
  3. Use the 'Auto' button for automatic setup of vertical, horizontal, and trigger settings.

4.2 Trigger Settings

The oscilloscope supports various trigger types to stabilize waveforms:

  • Edge Trigger: Triggers on a rising or falling edge of the input signal.
  • Pulse Width Trigger: Triggers on pulses of a specified width.
  • Video Trigger: Triggers on standard video signals.
  • Slope Trigger: Triggers on signals with a specific slope.
  • Overtime Trigger: Triggers when a signal remains above or below a threshold for a specified duration.

Access trigger settings via the 'Trigger' menu on the front panel.

4.3 Measurements

The DSO5072P offers multiple automatic measurements and cursor measurements:

  • Automatic Measurements: Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Period Mean, Period RMS, FOVShoot, RPREShoot, BWIDTH, FRF.
  • Cursor Measurements: Voltage difference (ΔV), Time difference (ΔT), and Reciprocal of ΔT (Frequency).
Hantek DSO5072P displaying various waveforms
Figure 4.1: Examples of waveforms displayed on the DSO5072P screen.
Hantek DSO5072P displaying multiple channel waveforms
Figure 4.2: Multi-channel waveform display and measurement on the DSO5072P.

4.4 Math Functions

The oscilloscope includes built-in math functions: Addition (+), Subtraction (-), Multiplication (x), Division (÷), and Fast Fourier Transform (FFT).

Hantek DSO5072P displaying FFT analysis
Figure 4.3: FFT analysis function in use on the DSO5072P.

4.5 PC Software

Install the Hantek software from the included CD on your PC to enable real-time analysis and control of the oscilloscope via the USB connection.

Video 4.1: Overview of Hantek oscilloscope features and operation.

5. Maintenance

5.1 Cleaning

Regularly clean the exterior of the oscilloscope with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and unplugged before cleaning.

5.2 Storage

Store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures. When not in use for extended periods, disconnect all cables.

5.3 Probe Care

Handle probes carefully. Avoid bending or stressing the probe tips and cables. Periodically check probe compensation for accurate measurements.

6. Troubleshooting

ProblemPossible CauseSolution
No powerPower cable not connected, power outlet faulty, power button not pressed.Check power cable connection, try a different outlet, ensure power button is pressed.
No waveform displayedProbe not connected, signal source off, incorrect vertical/horizontal settings, trigger issues.Verify probe connection, check signal source, adjust VOLTS/DIV and TIME/DIV, use 'Auto' button, check trigger settings.
Distorted waveformImproper probe compensation, probe faulty, signal integrity issues.Perform probe compensation, try a different probe, check signal source for noise.
USB connection issuesIncorrect USB cable, driver not installed, software not running.Ensure correct USB cable, install Hantek software and drivers from CD, restart PC and oscilloscope.

7. Specifications

FeatureSpecification
ModelDSO5072P
Bandwidth70MHz
Channels2
Real-Time Sample Rate1GSa/s
Equivalent Sample Rate25GSa/s
Record Length24K
Rise Time5ns
Time Base Accuracy±50ppm
Time Base Range4ns/div - 40s/div
Input Impedance1MΩ
VOLTS/DIV Range2mV/div - 5V/div
A/D Converter8 bit
DC Gain Accuracy±3% (5V/div to 10mV/div), ±4% (5mV/div to 2mV/div)
Bandwidth Limit20MHz
Display7" TFT 16K Color LCD, 800*480 dots
Dimensions313mm x 108mm x 142mm
Weight2.08KG
CertificationCE
Battery IncludedNo
IS Battery DemountableNo

8. User Tips

Consider the following tips for optimal use and longevity of your oscilloscope:

  • Always perform probe compensation before critical measurements to ensure accuracy.
  • Utilize the 'Auto' button for quick setup, then fine-tune settings manually for precise analysis.
  • When measuring high-frequency signals, ensure proper grounding to minimize noise interference.
  • Keep the firmware updated by checking the official Hantek website for the latest versions.
  • Protect the display from scratches and impacts.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official Hantek website or contact your local distributor. Keep your purchase receipt as proof of purchase.

© 2024 Hantek. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.