1. Introduction
Thank you for choosing the Jebao ECP Series Variable Frequency Cross Flow Pump. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new wave-making pump. Designed for both marine and fresh water aquariums, this pump offers advanced features such as variable frequency control, quiet operation, and intelligent wave-making capabilities to simulate natural aquatic environments.
The ECP+M series features smart WiFi and Bluetooth control, allowing for remote operation and advanced scheduling. The ECP series provides reliable performance with manual button control.
2. Safety Information
Please read all safety instructions carefully before use and retain this manual for future reference.
- Ensure the power supply voltage matches the pump's requirements.
- The pump operates on safe low voltage (DC 24V) after conversion from high voltage (e.g., 220V). This design strictly prevents electric leakage.
- Do not touch the power adapter or controller with wet hands.
- Keep the controller dry and away from water.
- The pump features IC electronic detection for dry/locked rotor protection and automatic power-off upon no water to prevent damage.
- No exposed copper elements, making it safe for both marine and fresh water environments.
- Always unplug the pump from the power source before performing any maintenance or cleaning.
- Ensure the pump is fully submerged during operation.

Figure 2.1: Safe Low Voltage Connection Diagram and Controller Warning
3. Package Contents
Upon unpacking, please verify that all the following items are included:
- Jebao Cross Flow Pump Unit
- External Controller (ECP-180M: WiFi/Bluetooth enabled; ECP-180: Manual button control)
- Power Adapter
- Mounting Bracket with Magnetic Suction Cups
- Instruction Manual (this document)
4. Specifications
| Feature | ECP-180 | ECP-180M |
|---|---|---|
| Model Number | ECP-180 | ECP-180M |
| Power (W) | 65W | Variable Frequency (Energy Saving) |
| Flow Rate | 13200-33000 L/H | Up to 33000 L/H (Variable) |
| Voltage | DC 24V | DC 24V |
| Recommended Fish Tank Size | 1.5-1.8M | 1.5-1.8M |
| Thickness of Magnetic Attraction | ≤19MM | ≤19MM |
| Pump Dimensions (L×W×H) | 340×82×52 MM | 340×82×52 MM |
| Control Method | Manual Button Control | External Control (WiFi & Bluetooth) |
| Noise Level | Ultra Quiet (approx. 28dB) | Ultra Quiet (approx. 28dB) |
| Impeller Structure | Cross Wave Double Impeller | Cross Wave Double Impeller |

Figure 4.1: ECP-180 Model Specifications and Controller
5. Setup Instructions
5.1 Mounting the Pump
- Identify the desired location for the pump inside your aquarium. The cross-flow design ensures water movement without dead spots.
- Attach the pump unit to the inside of the aquarium glass using the magnetic mounting bracket. Ensure the external magnet is securely placed on the outside of the glass, directly opposite the internal pump unit. The maximum recommended glass thickness for magnetic attraction is 19mm.
- Position the pump to achieve optimal water circulation and wave patterns for your specific tank setup.
5.2 Connecting the Controller and Power
- Connect the pump unit cable to the designated port on the external controller.
- Connect the power adapter to the controller.
- Plug the power adapter into a suitable electrical outlet. Ensure the plug type matches your region (US, EU, UK, AU).

Figure 5.1: Pump Connection Diagram

Figure 5.2: Available Plug Types
6. Operating Instructions
6.1 Control Methods
- ECP-180 (Manual Button Control): Use the buttons on the controller to adjust settings and switch between modes.
- ECP-180M (External Control with WiFi & Bluetooth): Utilize the dedicated mobile application for comprehensive control, scheduling, and mode selection. The ECP-180M supports AP mode control, meaning a router is not always required for direct connection.
6.2 Wave Making Modes and Functions
The Jebao ECP pump offers multiple modes to simulate various natural aquatic environments:
- Wave-making Mode: Simulates the natural ocean waves.
- Tidal Mode: Provides gradual power output and continuously circulating water flow, from small to large.
- Constant-Current Mode: Delivers continuous and fixed rapid water flow, ensuring flat and stable water movement.
- Feeding Mode: Automatically suspends pump operation for 10 minutes during feeding times to prevent food from being swept away.
- Turbulence Mode: Generates strong turbulence and wave action.
- Night Mode: Utilizes intelligent recognition via photosensitive detection to activate low-gear (power) operation at night, ensuring quiet performance during rest periods.

Figure 6.1: Overview of Wave Making Modes and Functions

Figure 6.2: WiFi Remote Control and Intelligent Timing
6.3 Wireless Linkage (ECP-180M)
The ECP-180M supports wireless linkage, allowing a mobile phone to control up to 32 different devices simultaneously. An infinite linkage controller can be set with a master controller, and multiple master controllers can synchronously control slave controllers through wireless transmission of instructions to realize multi-system combination.

Figure 6.3: Auto Frequency Control and Wireless Linkage
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your Jebao Cross Flow Pump.
- Cleaning: Periodically remove the pump from the aquarium and disassemble the impeller section for cleaning. Use a soft brush to remove any algae, debris, or calcium buildup. Rinse thoroughly with clean water.
- Impeller Inspection: Check the impellers for any signs of wear or damage. Replace if necessary.
- Controller Care: Keep the controller clean and dry. Avoid exposing it to moisture or direct sunlight.
- Cable Inspection: Regularly inspect the power cable and pump cable for any signs of damage.
The pump's efficient circulation helps in the removal of fish waste, contributing to a cleaner aquarium environment and potentially reducing the frequency of manual cleaning.
8. Troubleshooting
The controller is equipped with error codes to help diagnose common issues:
| Error Code | Description | Possible Solution |
|---|---|---|
| ER01 | Software Overcurrent Protection | Check for blockages in the pump or impeller. Restart the pump. If the issue persists, contact support. |
| ER02 | Hardware Overcurrent Protection | Unplug the pump immediately. Check for any physical damage or short circuits. Contact support. |
| ER03 | Overheating Protection | Ensure the pump is fully submerged and has adequate water flow for cooling. Allow the pump to cool down before restarting. |
| ER04 | Under Voltage Protection | Verify the power adapter is correctly connected and receiving sufficient voltage. Check for loose connections. |
| ER05 | Over Voltage Protection | Unplug the pump. Ensure the power source is stable and within the specified voltage range. Contact support if the issue persists. |
| ER06 | Rotor Clogging Protection | Disconnect power, remove the pump, and thoroughly clean the impellers and pump housing to remove any debris or blockages. |

Figure 8.1: Error Code Explanations
9. User Tips
- Optimal Placement: Experiment with different pump placements in your tank to find the best circulation pattern for your specific aquascape and inhabitants.
- App Features: For ECP-180M users, explore the mobile app's intelligent timing features to create dynamic wave patterns throughout the day, mimicking natural reef conditions.
- Energy Efficiency: The variable frequency technology and intelligent modes contribute to significant energy savings. For example, compared to other cross-flow pumps, the Jebao ECP series can save approximately $54 per year based on $0.1 per kWh.
- Quiet Operation: The SINE wave technology and Permanent Magnet Synchronous Motors (PMSMs) ensure ultra-quiet operation, making it suitable for living areas.
- Regular Checks: Periodically check the pump for any signs of reduced flow or unusual noise, which could indicate a need for cleaning.

Figure 9.1: Noise Level Comparison

Figure 9.2: Energy Saving Comparison
10. Warranty and Support
The Jebao ECP Series Cross Flow Pump comes with a 3-year warranty and lifelong after-sales service, ensuring peace of mind with your purchase. For technical assistance, troubleshooting beyond the scope of this manual, or warranty claims, please contact the seller or authorized service center. Please have your product model and purchase information ready when contacting support.